Medisana 40012

Medisana 40012 Air Humidifier User Manual

Model: 40012

1. Introduction

Thank you for choosing the Medisana 40012 Air Humidifier. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your device. Please read these instructions carefully before use and keep them for future reference.

2. Important Safety Instructions

3. Product Overview

The Medisana 40012 Air Humidifier is designed to improve air quality by adding moisture to the air. It features a user-friendly design with advanced functionalities.

Medisana 40012 Air Humidifier front view

Image 1: Front view of the Medisana 40012 Air Humidifier. Shows the main unit with the mist outlet and control panel.

Key Features:

4. Setup

  1. Unpacking: Carefully remove the humidifier from its packaging. Retain the packaging for future storage or transport.
  2. Placement: Place the humidifier on a flat, stable, and water-resistant surface at least 15 cm away from walls and furniture. Ensure the mist outlet is not directed towards electronic devices or moisture-sensitive materials.
  3. Filling the Water Tank:
    • Remove the water tank from the base unit.
    • Unscrew the tank cap and fill the tank with clean, cool tap water. Do not use hot water or add essential oils directly into the tank.
    • Securely screw the tank cap back on.
    • Place the filled water tank back onto the base unit, ensuring it is seated correctly.
  4. Power Connection: Plug the power cord into a suitable electrical outlet.

5. Operating Instructions

  1. Power On/Off: Press the power button on the touch panel to turn the humidifier on or off. The indicator light will illuminate when the device is active.
  2. Mist Level Adjustment: Press the mist level button to cycle between the two available mist output levels (Low and High). The corresponding indicator will light up.
  3. Water Level Indicator: The water level indicator will show the current water level in the tank. When the water level is low, the device will emit an audible alert and automatically shut off for safety. Refill the tank to resume operation.
  4. 360-Degree Mist Outlet: Rotate the mist outlet nozzle to direct the mist in any desired direction.

6. Maintenance and Cleaning

Regular cleaning is crucial for maintaining the efficiency and longevity of your humidifier and preventing the growth of bacteria and mold.

Daily Maintenance:

Weekly Cleaning:

  1. Unplug the humidifier and remove the water tank.
  2. Descaling the Water Tank: Fill the water tank with a solution of 1 part white vinegar and 1 part water. Let it sit for 30 minutes, then rinse thoroughly.
  3. Cleaning the Base Unit: Pour a small amount of the vinegar solution into the base unit and let it sit for 30 minutes. Gently scrub any mineral deposits with a soft brush or cloth. Do not immerse the base unit in water.
  4. Rinse all components thoroughly with clean water until the vinegar smell is gone.
  5. Wipe all parts dry before reassembling.

7. Troubleshooting

If you encounter any issues with your Medisana 40012 Air Humidifier, please refer to the table below for common problems and solutions.

ProblemPossible CauseSolution
No mist outputNo water in tank; Power not connected; Mist outlet blocked; Mineral buildup.Refill water tank; Check power connection; Clear mist outlet; Clean the unit.
Unusual odorStagnant water; Dirty water tank/base.Empty and clean the water tank and base unit thoroughly. Use fresh water.
Water leakageWater tank cap not secured; Tank not seated correctly; Unit on uneven surface.Ensure tank cap is tight; Re-seat the water tank; Place unit on a flat surface.
Loud noise during operationUnit on uneven surface; Water level too low.Place unit on a flat surface; Refill water tank.

8. Technical Specifications

FeatureSpecification
BrandMedisana
Model Number4015588400124 (also known as 40012)
Power23 W
Water Tank Capacity3.6 Liters
MaterialPlastic
Operating ModeEvaporator
Run TimeUp to 10 hours
Approximate Package Dimensions45 x 45 x 45 cm
Approximate Package Weight4 Kilograms

9. Warranty and Customer Support

Medisana products are manufactured to high-quality standards. This product is covered by a manufacturer's warranty in accordance with the legal provisions of your country of purchase. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Medisana website.

For technical support, spare parts, or any questions regarding your Medisana 40012 Air Humidifier, please contact Medisana customer service. Contact details can typically be found on the official Medisana website or in the product packaging.

Related Documents - 40012

Preview Medisana AH 670 Air Humidifier - Instruction Manual
Official instruction manual for the Medisana AH 670 air humidifier. Provides product information and important usage guidelines.
Preview medisana BU 535 Voice Blutdruckmessgerät: Gebrauchsanweisung und Bedienung
Umfassende Gebrauchsanweisung für das medisana BU 535 Voice Oberarm-Blutdruckmessgerät. Erfahren Sie mehr über Funktionen, sichere Anwendung, Messung, Speicherung und Fehlerbehebung.
Preview medisana BW 360 connect Handgelenk-Blutdruckmessgerät: Bedienungsanleitung
Erfahren Sie alles über Ihr medisana BW 360 connect Handgelenk-Blutdruckmessgerät. Diese Anleitung bietet detaillierte Informationen zur sicheren Anwendung, Messung, Bluetooth-Konnektivität und Fehlerbehebung für präzise Gesundheitsüberwachung zu Hause.
Preview medisana Körperanalysewaage BS 600: Ihr umfassender Gesundheitsbegleiter
Entdecken Sie die medisana Körperanalysewaage BS 600 für detaillierte Einblicke in Gewicht, Körperfett, Wassergehalt, Muskelmasse und mehr. Verbinden Sie sie mit der VitaDock+ App für ein ganzheitliches Gesundheitsmanagement.
Preview MEDISANA Kuschel-Heizdecke HB 675 Bedienungsanleitung
Bedienungsanleitung für die MEDISANA Kuschel-Heizdecke HB 675. Enthält wichtige Informationen zu Sicherheit, Anwendung, Reinigung und Garantie.
Preview Medisana BS 444 Body Analysis Scale User Manual
Comprehensive user manual for the Medisana BS 444 Body Analysis Scale, covering safety instructions, operation, technical data, warranty, and troubleshooting.