Adviace 2800000.0
Adviace Replacement Fireplace Fan Blower and Heating Element User Manual
Model: 2800000.0
1. Product Overview
The Adviace Replacement Fireplace Fan Blower and Heating Element is a professional-grade tangential blower designed to replace existing units in compatible Twinstar electric fireplaces and wood-burning stoves. Its primary function is to efficiently distribute heat generated by the fireplace into the room, enhancing comfort. This unit combines a quiet-running fan with a robust heating coil to ensure effective heat transfer.

Image 1.1: The Adviace Replacement Fireplace Fan Blower and Heating Element, showing the complete assembly of the blower and heating coil.
2. Safety Information
Before attempting any installation or maintenance, please read and understand all safety warnings. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- ALWAYS disconnect power to the fireplace unit by unplugging it from the wall outlet before beginning any installation, maintenance, or troubleshooting.
- Ensure the fireplace unit is completely cool before handling any internal components.
- Only use this replacement part for the specified Twinstar models. Using it with incompatible models may cause damage or create a safety hazard.
- If you are unsure about any step of the installation process, consult a qualified electrician or technician.
- Keep all wiring connections secure and insulated to prevent short circuits.
- Do not operate the fireplace if the blower or heating element is damaged or not functioning correctly.
3. Product Specifications
This section details the physical and electrical specifications of the replacement fan blower and heating element.
| Feature | Specification |
|---|---|
| Fan Blower Size (L x W x H) | 9.75" x 3.73" x 3.23" |
| Fan Blower Diameter x Length | 2.36" x 7.28" |
| Heater Element Size (L x W) | 7.87" x 1.38" |
| Wattage | 1350W |
| Voltage | 120V |
| Item Model Number | 2800000.0 |
| Product Weight | 1.85 Pounds (0.84 Kilograms) |

Image 3.1: Detailed dimensions of the fan blower and heating element for accurate measurement and fit.
4. Compatibility
This replacement fan blower and heating element is specifically designed for the following Twinstar brand electric fireplace series:
- 28E05
- 28E05R
- TS-001
- 23EF010GAA
- 10QI071ARA
IMPORTANT: This fan is only available for these listed models under the Twinstar brand. Please measure the space for installing this fan blower in your stove or fireplace and compare it with the dimensions provided in Section 3 to ensure proper fit. "Measure Twice...Buy Once..."

Image 4.1: Visual representation of compatible Twinstar electric fireplace models.
5. Installation Guide
Follow these steps carefully to install your new replacement fan blower and heating element. It is recommended to take photos of the existing wiring before disconnection for easy reference during reassembly.
- Step 1: Turn Off and Unplug the Fireplace. Safety first! Make sure your fireplace is completely turned off and unplugged from the wall. This is crucial to avoid any electrical mishaps during the installation.
- Step 2: Access the Blower Compartment. Depending on your Twinstar model, you'll likely need to remove the back panel or base of the unit to access the blower. Use your screwdriver to remove the screws and gently set the panel aside.
- Step 3: Remove the Existing Blower. Once you locate the blower, disconnect any electrical connections (take a picture of the wiring for easy reference later). Use your wrench to unfasten any bolts or screws holding the blower in place, then carefully remove it.
- Step 4: Prepare the New Blower for Installation. Inspect the new blower and ensure all components are intact. Compare it with the old blower to make sure they are identical in size and design. If necessary, make adjustments according to the manufacturer's instructions.
- Step 5: Install the Replacement Blower. Carefully position the new blower in place, aligning it with the screw holes or mounting brackets. Secure it with the screws or bolts you removed earlier. Reconnect the electrical wiring based on the reference photo you took.
- Step 6: Test the New Blower. Before reassembling the fireplace, plug it in and test the blower. Make sure it runs smoothly without unusual sounds. If everything checks out, go ahead and replace the panel you removed earlier.

Image 5.1: Visual guide illustrating the six key installation steps for the replacement blower.

Image 5.2: Close-up view of the wiring connections on the blower, important for correct reassembly.
6. Operating Instructions
Once installed, the Adviace Replacement Fireplace Fan Blower and Heating Element operates in conjunction with your fireplace's existing controls. It is designed to automatically activate when the fireplace's heating function is engaged, circulating warm air into your living space.
- Ensure the fireplace unit is plugged into a properly grounded electrical outlet.
- Use the original controls of your Twinstar electric fireplace to turn on the heating function. The blower should begin to operate, distributing heat.
- Listen for any unusual noises during operation. A properly installed unit should run quietly.
7. Maintenance
Regular maintenance helps ensure the longevity and efficient operation of your replacement fan blower and heating element.
- Annual Inspection: At least once a year, or more frequently if the fireplace is used heavily, unplug the fireplace and allow it to cool. Access the blower compartment as described in the installation steps.
- Cleaning: Gently clean any dust or debris from the fan blades and heating element using a soft brush or a vacuum cleaner with a brush attachment. Do not use water or liquid cleaners on electrical components.
- Wiring Check: Inspect all electrical connections for any signs of wear, fraying, or looseness. Re-secure any loose connections.
- Obstruction Check: Ensure there are no obstructions around the fan or heating element that could impede airflow.
8. Troubleshooting
If you encounter issues with your replacement fan blower and heating element, refer to the following common problems and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Blower not operating | No power to fireplace; Loose wiring connection; Faulty heating element/blower | Check if fireplace is plugged in and power outlet is working. Inspect all wiring connections for tightness. If power is present and connections are secure, the unit may be faulty and require replacement. |
| Blower is noisy | Debris in fan; Loose mounting; Worn bearings | Unplug and cool fireplace. Access blower and carefully remove any debris. Check mounting screws for tightness. If noise persists, bearings may be worn, indicating the unit needs replacement. |
| No heat output | Heating element failure; Incorrect wiring | Ensure all heating element wires are correctly connected. If the blower runs but no heat is produced, the heating element may be faulty and require replacement. |
If troubleshooting steps do not resolve the issue, or if you suspect a more serious problem, discontinue use and consult a qualified technician.
9. Warranty and Support
For information regarding warranty coverage or technical support for your Adviace Replacement Fireplace Fan Blower and Heating Element, please refer to the original purchase documentation or contact Adviace customer service directly. Ensure you have your product model number (2800000.0) and purchase date available when contacting support.
For further assistance, you may visit the Adviace Store on Amazon: Adviace Store