Introduction
This manual provides instructions for the EPEVER Tracer AN Series MPPT Solar Charge Controller, specifically the 10A model (Tracer1210AN). This controller utilizes advanced Maximum Power Point Tracking (MPPT) technology to optimize solar energy harvesting and manage battery charging efficiently.

Front view of the EPEVER Tracer AN Series 10A MPPT Solar Charge Controller, showing the LCD display and control buttons.
Key features of this controller include:
- Advanced MPPT (Maximum Power Point Tracking) technology, with efficiency no less than 99.5% and a maximum conversion efficiency of 98%.
- Features an LCD display for real-time operational status.
- Precise tracking of the photovoltaic array's Maximum Power Point (MPP) in all situations, maximizing solar energy harvest over time and significantly improving energy efficiency.
- Equipped with a Modbus communication protocol interface, allowing for convenient expansion of applications and monitoring in various fields such as telecommunication stations, home systems, street lighting systems, and environmental monitoring systems.
- Supports PC monitoring and external display units like the MT50, enabling real-time data control and parameter settings. Software updates are also supported.
Installation and Wiring
Proper installation and wiring are crucial for the safe and efficient operation of your solar charge controller. Please follow these guidelines carefully.
Wiring Diagram

This diagram illustrates the correct connection sequence: 1. Battery, 2. Load, 3. PV Array. Disconnect in reverse order.
Important Cautions
- CAUTION: When wiring the controller, do not close the circuit breaker or fuse. Ensure that the positive ("+") and negative ("-") leads are connected correctly.
- CAUTION: A fuse, with a current rating 1.25 to 2 times the controller's rated current, must be installed on the battery side. The distance from the battery should not exceed 150 mm.
- CAUTION: If the controller is used in an area with frequent lightning strikes or is an unattended area, an external surge arrester must be installed.
- CAUTION: If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.
Operation
LCD Display Overview
The integrated LCD provides real-time information about the system's status, allowing you to monitor various parameters.

This image displays the various screens available on the LCD, including PV Input Voltage, Charging Current, Energy Generation, Load Working Mode, Battery Voltage, Battery Current, Load Usage Statistics, Discharge Current, and Temperature.
Setting Battery Type
Follow these steps to configure the battery type via the LCD display:

This image illustrates the sequence for setting the battery type.
- Step 1: Press the SELECT button to navigate to the battery voltage interface.
- Step 2: Press and hold the ENTER button until the battery type interface flashes.
- Step 3: Press the SELECT button to modify the battery type. Options include Sealed (default), Gel, Flooded, LCNM3S, LFP8S, LFP4S, LCNM6S, LCNM7S, and User-defined.
- Step 4: Press the ENTER button to confirm the selection.
Interface Icons
The following table explains the meaning of the icons displayed on the controller's interface.

This image provides a visual guide to the various icons and their corresponding statuses for the PV array, battery, and load.
| Item | Icon | Status |
|---|---|---|
| PV array | Day | |
| PV array | Night | |
| PV array | No charging | |
| PV array | Charging | |
| PV array | PV | PV Voltage, Current, Power |
| Battery | Battery capacity, in Charging | |
| Battery | BATT. | Battery Voltage, Current, Temperature |
| Battery | BATT. TYPE | Battery type |
| Load | Load ON | |
| Load | Load OFF | |
| Load | LOAD | Load Voltage, Current, Load mode |
Maintenance
To ensure optimal performance and longevity of your EPEVER MPPT solar charge controller, regular maintenance is recommended.
- Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
- Keep the controller clean and free from dust and debris. Ensure proper ventilation around the unit.
- Monitor the LCD display for any error codes or unusual readings. Refer to the troubleshooting section if issues arise.
- Ensure the ambient temperature around the controller remains within its specified operating range to prevent overheating.
Troubleshooting
This section provides guidance for common issues you might encounter with your solar charge controller.
- Controller Not Charging: Check PV array connections, ensure sufficient sunlight, verify battery connections, and check for blown fuses. Confirm that the PV input voltage is within the controller's operating range.
- Low Charging Current: Inspect PV panel cleanliness, check for shading, and confirm battery type settings are correct. Ensure all connections are secure and there is no excessive voltage drop.
- LCD Display Not Working: Verify battery connection and voltage. Ensure the controller is receiving power. If the issue persists, contact support.
- Load Output Off (Over-Discharge Protection): If the load output is off, the battery voltage may be too low. The load will automatically reconnect once the battery recovers to a safe voltage level.
- Overheating: Ensure the controller has adequate ventilation and is not installed in an enclosed space without airflow. Reduce load if necessary.
Technical Specifications
Key technical details for the EPEVER Tracer1210AN MPPT Solar Charge Controller.

This image provides a detailed specification table for the Tracer AN series, including the Tracer1210AN model.
| Feature | Detail |
|---|---|
| Model | Tracer1210AN |
| Brand | EPEVER |
| Rated Charge Current | 10A |
| System Voltage | 12V / 24V DC Auto Identification |
| Rated Charge Power (12V) | 130W |
| Rated Charge Power (24V) | 260W |
| Max. PV Array Power (12V) | 195W |
| Max. PV Array Power (24V) | 390W |
| Max. PV Open Circuit Voltage | 92V (at 25°C environment temperature), 100V (at minimum operating environment temperature) |
| Dimensions (L x W x H) | 17.2 x 13.9 x 4.4 cm |
| Weight | 720 Grams |
| Material | Plastic |
| Display Type | LCD |
| Operating Temperature | Up to 45°C |
| GTIN / UPC | 680465249352 |
Warranty and Support
For product support, please refer to the official EPEVER website or contact your local distributor. Detailed warranty information is typically provided with the product packaging or available on the manufacturer's website.
The controller supports PC monitoring and external display units (e.g., MT50) for advanced data control and parameter settings. Software updates are also supported to ensure your controller remains up-to-date with the latest features and improvements.

This image shows optional accessories (not included) such as RS485 communication cables, Wi-Fi and Bluetooth modules (eBox-WiFi-01, eBox-BLE-01), USB adapters, and the MT50 external display unit, which enable PC and mobile app monitoring. A temperature sensor (RTS300R47K3.81A) is also depicted.