1. Product Overview
The Zopsc Waterproof Keypad Access Control is a multi-functional, integrated access control device designed for enhanced security in various environments such as homes, offices, and residential areas. It features a robust waterproof design suitable for outdoor use and supports multiple access methods.
Key Features:
- Multiple Access Options: Supports access via RFID cards, password entry, or a combination of card and password.
- Durable Construction: Features a strong Zinc Alloy electroplated anti-vandal case, providing resistance against explosion and prying.
- Waterproof Design: IP67 rated, making it suitable for outdoor installation and use in various weather conditions.
- Luminous Keyboard: Equipped with intelligent keyboard lights for clear visibility and operation in low-light conditions.
- User Management: Capable of storing up to 2000 users. Includes an administrator card for quick user addition and deletion.
- Security Functions: Incorporates anti-stress and anti-submarine back functions for enhanced security. Features an anti-theft alarm output for external alarm devices.
- Wiegand Output: Provides Wiegand output interface (Wg26 card number or Wg4 buttons) for integration with other access control systems.
- Low Power Consumption: Operates with a static current of less than 50mA.

Figure 1: Front view of the Zopsc Waterproof Keypad Access Control System.
2. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:
- 1 x Metal Waterproof Access Controller
- 2 x Access Controller Cards (RFID)
- 1 x Set of Installation Accessories (screws, anchors)
- 1 x English User Manual

Figure 2: Contents included in the product package.
3. Specifications
| Feature | Specification |
|---|---|
| Item Type | Access Controller |
| Color | Silver |
| Work Voltage | DC 10V (Note: Product description states DC 10-24V) |
| Static Current | <=50mA |
| Reading Range | 2-5cm |
| User Capacity | 2000 users |
| Ambient Temperature | -40-60℃ |
| Ambient Humidity | 0%-98% |
| Electric Lock Output | 3A |
| Alarm Output | <=500mA |
| Open Time | 0-120 seconds (adjustable) |
| Dimensions | 11 x 7.5 x 2.2 cm (4.33 x 2.95 x 0.86 inches) |
| Weight | 480 g (18.41 oz) |
| Waterproof Rating | IP67 |
| UPC | 746771453460 |
4. Installation
The Zopsc Waterproof Keypad Access Control System is designed for straightforward installation. Ensure you have the necessary tools and follow local electrical codes.
4.1 Physical Installation
- Choose Location: Select a suitable mounting location, preferably near the door or gate where access control is desired. Ensure the surface is flat and stable.
- Mark Drilling Points: Use the backplate of the access controller as a template to mark the drilling points on the wall.
- Drill Holes: Drill holes at the marked points. Insert wall anchors if necessary.
- Mount the Backplate: Secure the backplate to the wall using the provided screws.
- Connect Wiring: Route the necessary wiring through the wall opening to the back of the access controller. Refer to the wiring diagram in Section 4.2.
- Attach the Controller: Carefully align the access controller with the mounted backplate and secure it.

Figure 3: The compact size of the access controller for easy handling.

Figure 4: The durable zinc alloy case ensures longevity in various environments.
4.2 Wiring Diagram
The access controller requires connection to a DC 10-24V power supply and a compatible electric lock (e.g., electromagnetic lock, electric strike). It also supports an exit button and an external alarm device.

Figure 5: Rear view of the access controller with wiring connections.
Typical Wiring Connections:
- Power Input: Connect the DC 10-24V power supply to the designated power input terminals (usually marked +V and GND).
- Electric Lock: Connect the electric lock to the NO (Normally Open) or NC (Normally Closed) and COM (Common) terminals, depending on the lock type (fail-safe or fail-secure).
- Exit Button: Connect an external exit button to the PUSH and GND terminals.
- Alarm Output: Connect an external alarm device to the ALARM terminals if desired.
- Wiegand Output: For integration with other access control panels, connect the Wiegand output (D0, D1) to the corresponding Wiegand input on the main controller.
Note: Always refer to the detailed wiring instructions provided in the included English User Manual for specific terminal assignments and safety precautions. Incorrect wiring can damage the device or connected components.
Video 1: Overview of the Zopsc Keypad Access Control System components and basic handling.
5. Operation
The Zopsc Keypad Access Control System offers flexible options for granting access.
5.1 Access Methods
- Card Access: Present a registered RFID card to the reader area on the keypad. The door will unlock if the card is valid.
- Password Access: Enter a valid 4-6 digit password on the keypad. The door will unlock if the password is correct.
- Card + Password Access: Present a registered RFID card, then immediately enter the corresponding password. This method provides a higher level of security.

Figure 6: The keypad allows for secure password entry.
5.2 User Management
The system uses an administrator card for efficient user management. Detailed instructions for adding and deleting users via the administrator card and keypad commands are provided in the full user manual.
- Adding Users: Use the administrator card to enter programming mode, then follow the prompts to register new RFID cards or set new user passwords.
- Deleting Users: The administrator card can also be used to delete individual users or all users from the system.
- User Modification Password: Users can revise their own door passwords.
5.3 Advanced Functions
- Anti-Theft Alarm: If the device is illegally dismantled, the built-in alarm buzzer will activate, and the anti-theft alarm output will trigger external alarm devices.
- Anti-Stress/Anti-Submarine Back Function: These features enhance security by preventing unauthorized access attempts through specific attack methods.
- Luminous Keyboard: The keypad automatically illuminates, allowing for easy operation in dark environments.

Figure 7: The luminous keyboard ensures visibility at night.
6. Maintenance
Proper maintenance ensures the longevity and reliable operation of your Zopsc Waterproof Keypad Access Control System.
- Regular Cleaning: Wipe the keypad surface with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners or solvents that could damage the finish or electronics.
- Inspect Wiring: Periodically check all wiring connections for any signs of wear, corrosion, or loose connections. Ensure all connections are secure.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure optimal performance and security.
- Environmental Protection: Although the device is IP67 waterproof, avoid prolonged submersion or exposure to extreme conditions beyond its specified operating range.

Figure 8: The IP67 waterproof rating allows for reliable outdoor use.
7. Troubleshooting
If you encounter issues with your Zopsc Waterproof Keypad Access Control System, refer to the following common troubleshooting steps:
- No Power: Check the power supply connections and ensure the power source is active (DC 10-24V). Verify that the power supply is functioning correctly.
- Keypad Unresponsive: Ensure the power supply is stable. If the keypad is completely unresponsive, try power cycling the device.
- Door Not Unlocking:
- Verify that the RFID card or password entered is correct and registered.
- Check the wiring to the electric lock and ensure it is correctly connected to the NO/NC and COM terminals.
- Ensure the electric lock itself is functioning properly.
- Exit Button Not Working: Check the wiring connections for the exit button to the PUSH and GND terminals. Ensure the button itself is not faulty.
- Alarm Malfunction: Verify the alarm output wiring. Check the external alarm device for proper functionality.
- Card Reading Issues: Ensure the RFID card is presented correctly within the 2-5cm reading range. Check for any obstructions or interference.
For persistent issues not resolved by these steps, please contact customer support.
8. Warranty and Support
Information regarding product warranty and customer support details is typically provided in the full user manual included with your product or can be found on the manufacturer's official website. Please retain your proof of purchase for warranty claims.
For technical assistance, troubleshooting, or service inquiries, please refer to the contact information provided by Zopsc.