iMeshbean 010-09

iMeshbean Deep Well Submersible Pump User Manual

Model: 010-09

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your iMeshbean Deep Well Submersible Pump, Model 010-09. Please read this manual thoroughly before installation and use to ensure proper function and to prevent injury or damage.

iMeshbean Deep Well Submersible Pump with Control Box and Motor Diagram

Figure 1: iMeshbean Deep Well Submersible Pump with key specifications.

2. Safety Information

WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death.

  • Always disconnect power before installing, servicing, or performing any maintenance on the pump.
  • Ensure all electrical connections comply with local codes and regulations. A qualified electrician should perform electrical wiring.
  • The pump is designed for use with 110V/115V, 60 Hz power supply. Verify your power source matches these requirements.
  • The pump must be fully submerged in water during operation to ensure proper cooling and prevent overheating. Operating the pump dry will cause severe damage.
  • An additional external check valve is highly recommended to prevent backflow and maintain system pressure, even if the pump has a built-in check valve.
  • Ensure the power cord length is appropriate for the well depth. Using an undersized or excessively long power cord can lead to voltage drop, overheating, and pump malfunction. Consult NEC guidelines for proper wire gauge selection.
  • Verify the circuit breaker in the control box is correctly rated for the pump's amperage draw. An incorrectly sized breaker can lead to nuisance tripping or inadequate protection.
Diagram showing correct and incorrect pump submersion and recommended additional check valve installation

Figure 2: Proper pump submersion and recommended additional check valve setup.

3. Product Components

The iMeshbean Deep Well Submersible Pump system includes the following main components:

  • Submersible Pump: Constructed with a stainless steel body and discharge head, featuring a permanent magnet motor and thermoplastic impellers for durability and efficient water transfer. Designed to fit in a 4-inch casing.
  • External Control Box: Houses the ON/OFF switch and provides overload and short circuit protection for the pump.
  • Power Cord: A 100-foot power cord is included for connection to the control box.
Diagram of multi-stage floating impeller

Figure 3: Multi-stage floating impeller design for powerful, high-lift, and sand-resistant operation.

Diagram of external control box connection to deep well pump and water tank

Figure 4: External control box and its connection to the deep well pump and water tank.

4. Specifications

FeatureSpecification
BrandiMeshbean
Model Number010-09
Power1 HP
Voltage110V / 115V
Frequency60 Hz
Maximum Flow Rate33 Gallons Per Minute (GPM)
Maximum Lifting Height (Head)305 Feet
Discharge Outlet1-1/2" NPT
Impellers9 (Thermoplastic)
Casing Diameter CompatibilityFits in a 4" casing
Power Cord Length100 Feet
MaterialStainless Steel, Cast Iron
Product Dimensions (L x W x H)10.6" x 4" x 23.6"
Item Weight33 Pounds
Special FeaturesExternal Control Box with ON/OFF switch, Built-in Thermal Protection

5. Installation Guide

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a qualified professional.

5.1 Pre-Installation Checks

  • Ensure the well casing is at least 4 inches in diameter to accommodate the pump.
  • Verify the static water level and total well depth to ensure the pump can be fully submerged and reach the desired depth without exceeding its maximum lift capacity.
  • Inspect the pump and control box for any visible damage from shipping.
  • Confirm the power supply matches the pump's voltage (110V/115V) and frequency (60 Hz).

5.2 Electrical Connection

  • Connect the pump's 100-foot power cord to the external control box. Follow the wiring diagram provided with the control box.
  • Connect the control box to your main power supply. Ensure a dedicated circuit with appropriate overcurrent protection is used.
  • Important Note: The provided 100ft power cord is designed for standard applications. For deeper wells or specific electrical requirements, it may be necessary to replace the cord with a heavier gauge wire to prevent voltage drop and ensure optimal performance. Consult a qualified electrician for proper wire sizing based on well depth and local electrical codes.
  • Circuit Breaker: Verify the circuit breaker in the control box is correctly sized for the pump's operating current (6.5 Amps). An undersized breaker may cause frequent tripping.
Comparison of 100ft full copper power cord versus shorter, inferior cords

Figure 5: The included 100ft full copper power cord is designed for reliability.

5.3 Plumbing Connection

  • Attach the discharge pipe to the pump's 1-1/2" NPT outlet. Use appropriate thread sealant for a watertight connection.
  • Check Valve: While the pump has a built-in check valve, installing an additional external check valve on the drop pipe above the torque arrestor is strongly recommended. This helps prevent backflow, water hammer, and maintains consistent water pressure.
  • Securely attach a safety rope or cable to the pump for lowering and retrieving it from the well. Do not use the power cord to support the pump's weight.
Close-up of 1-1/2 inch NPT discharge and pump being lowered into a well

Figure 6: The 1-1/2 inch NPT discharge connection and pump installation process.

5.4 Lowering the Pump

  • Carefully lower the pump into the well using the safety rope/cable. Ensure the pump remains vertical during lowering.
  • Lower the pump until it is fully submerged below the static water level, ensuring adequate clearance from the bottom of the well to avoid drawing in sand or sediment.
Diagram showing high lift and large flow capabilities, with a warning about installing the pump below water level and recommending an additional check valve.

Figure 7: The pump delivers high lift and large flow. Ensure it is installed below the water level.

6. Operating Instructions

Once the pump is correctly installed and all connections are secure:

  • Ensure the control box is mounted in a dry, accessible location.
  • Turn on the power supply to the control box.
  • Use the ON/OFF switch on the external control box to start the pump.
  • Monitor the system for proper water flow and pressure.
  • To stop the pump, switch the ON/OFF button to the OFF position.

7. Maintenance

The iMeshbean Deep Well Submersible Pump is designed for long-lasting use with minimal maintenance. However, regular checks can help ensure optimal performance:

  • Periodically check the water level in the well to ensure the pump remains fully submerged during operation.
  • Inspect the power cord for any signs of wear or damage.
  • Listen for unusual noises during operation, which could indicate a problem.
  • If an external check valve is installed, inspect it periodically for proper function.
  • In areas with high sediment, consider periodic well cleaning to prevent pump clogging.

8. Troubleshooting

If you encounter issues with your pump, refer to the following troubleshooting guide:

ProblemPossible Cause(s)Solution
Pump does not start or trips breaker immediately
  • No power to control box
  • Incorrect wiring
  • Short circuit in pump or wiring
  • Motor failure
  • Check power supply and control box connections.
  • Verify wiring against diagram.
  • Consult an electrician to check for short circuits.
  • Contact support if motor failure is suspected.
Pump runs for a short period then shuts off (trips)
  • Overload due to heavy load or foreign objects
  • Pump operating dry (not fully submerged)
  • Motor overheating (thermal protection activated)
  • Undersized circuit breaker in control box
  • Excessive voltage drop due to long/undersized power cord
  • Bearing failure
  • Check for foreign objects or sand in the pump; remove if found.
  • Ensure pump is fully submerged below water level.
  • Allow pump to cool down. Check well water level.
  • Verify circuit breaker rating matches pump specifications.
  • Consult an electrician to assess power cord gauge and length.
  • Contact support if bearing failure is suspected.
Low or no water flow
  • Low well water level
  • Clogged intake screen or impellers
  • Faulty check valve (internal or external)
  • Leak in discharge piping
  • Pump not fully submerged
  • Check well water level.
  • Retrieve pump and clean intake/impellers.
  • Inspect and replace faulty check valves.
  • Check all plumbing connections for leaks.
  • Ensure pump is adequately submerged.
Internal check valve does not hold pressureDefective internal check valve.Install an additional external check valve on the discharge pipe. This is a common solution and highly recommended.

9. Warranty and Support