1. Important Safety Information
Please read all instructions carefully before operating your Hisense Portable Air Conditioner. Keep this manual for future reference.
- Electrical Safety: Always plug the unit into a grounded 3-prong outlet. Do not use extension cords or adapter plugs. Ensure the power cord is not damaged or pinched.
- Placement: Place the unit on a firm, level surface. Maintain at least 20 inches (50 cm) of clearance from walls or other objects to ensure proper airflow. Do not block air inlets or outlets.
- Children and Pets: Keep children and pets away from the unit. Do not allow them to play with or around the appliance.
- Maintenance: Always unplug the unit before cleaning or performing any maintenance. Do not attempt to repair or modify the unit yourself. Contact qualified service personnel for repairs.
- Water Drainage: Ensure proper drainage of condensed water to prevent overflow and potential damage.
- Refrigerant: This unit contains R410A refrigerant. Do not puncture the refrigerant circuit.
2. Product Overview
Familiarize yourself with the components of your Hisense Portable Air Conditioner.
Figure 2.1: Front view of the Hisense AP14CR1SFTS00 Portable Air Conditioner. This image displays the main unit with its control panel and air outlet louvers.
Package Contents:
- Portable Air Conditioner Unit
- Exhaust Hose
- Window Slider Kit (includes window slider panels, adapter, and screws)
- Remote Control (with batteries)
- Drain Hose
- User Manual
3. Setup and Installation
Follow these steps to properly set up your portable air conditioner.
3.1 Window Kit Installation
- Measure your window opening.
- Adjust the window slider panels to fit the opening. Secure them with the provided screws.
- Insert the window kit into the window frame, ensuring a tight seal to prevent air leakage.
3.2 Exhaust Hose Connection
- Attach one end of the exhaust hose to the exhaust outlet on the back of the air conditioner unit. Twist clockwise until secure.
- Attach the other end of the exhaust hose to the adapter on the window slider kit.
- Ensure the exhaust hose is as short and straight as possible to maximize efficiency. Avoid sharp bends.
3.3 Power Connection
Plug the power cord into a standard, grounded 120V/60Hz electrical outlet. Do not use extension cords.
4. Operating Instructions
Your Hisense Portable Air Conditioner offers Cooling, Fan, and Dehumidifier modes.
4.1 Control Panel and Remote Control
The unit can be operated using the control panel on the top of the unit or the included remote control. Ensure batteries are installed correctly in the remote control.
4.2 Power On/Off
Press the POWER button to turn the unit on or off.
4.3 Mode Selection
Press the MODE button to cycle through the available modes:
- Cool Mode: For cooling the room. Use the UP/DOWN arrows to set the desired temperature (62°F - 86°F / 17°C - 30°C).
- Fan Mode: Circulates air without cooling. Select desired fan speed (Low, Medium, High).
- Dry (Dehumidifier) Mode: Reduces humidity in the room. The fan speed is automatically set to low in this mode.
4.4 Fan Speed Adjustment
In Cool or Fan mode, press the FAN SPEED button to select Low, Medium, or High fan speed.
4.5 Timer Function
The timer allows you to set the unit to turn on or off automatically after a set period (1-24 hours). Refer to the detailed instructions in the remote control section for specific timer programming.
4.6 Sleep Mode
Press the SLEEP button to activate sleep mode. In this mode, the set temperature will gradually increase by 2°F (1°C) over the first hour and another 2°F (1°C) over the second hour, then maintain this temperature for 6 hours before returning to normal operation. The fan speed will be set to low.
5. Maintenance and Cleaning
Regular maintenance ensures optimal performance and extends the life of your unit.
5.1 Air Filter Cleaning
The air filter should be cleaned every two weeks or more frequently depending on usage. A dirty filter reduces cooling efficiency.
- Unplug the unit from the power outlet.
- Remove the air filter from the back of the unit.
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinstalling. Do not expose to direct sunlight.
5.2 Water Drainage
The unit will automatically evaporate most of the condensed water. However, in high humidity conditions, the internal water tank may fill up. The unit will display an 'FL' (Full) error code and stop operating.
- Unplug the unit.
- Place a shallow pan or tray under the drain port at the bottom rear of the unit.
- Remove the drain plug to allow water to flow out.
- Once drained, replace the drain plug securely.
5.3 Unit Cleaning
Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
5.4 Storage
If storing the unit for an extended period:
- Drain all condensed water completely.
- Clean the air filter.
- Unplug the power cord and coil it neatly.
- Store the unit in a cool, dry place, covered to protect from dust.
6. Troubleshooting
Before contacting customer service, refer to the following table for common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, power cord unplugged, circuit breaker tripped. | Check power connection, reset circuit breaker. |
| Unit does not cool effectively. | Dirty air filter, blocked air intake/outlet, room too large, window/door open, exhaust hose not properly installed. | Clean air filter, ensure clear airflow, close windows/doors, check exhaust hose connection. |
| 'FL' error code displayed. | Internal water tank is full. | Drain the condensed water from the unit. |
| Unit is noisy. | Unit not on a level surface, fan speed too high, foreign object in fan. | Place on a level surface, reduce fan speed, check for obstructions (unplug first). |
7. Product Specifications
| Feature | Specification |
|---|---|
| Model Number | AP14CR1SFTS00 |
| Cooling Capacity | 14,000 BTU |
| Functions | Cooling, Fan, Dehumidifier |
| Refrigerant | R410A |
| Noise Level | 50 Decibels |
| Power Source | Corded Electric |
| Seasonal Energy Efficiency Ratio (SEER) | 7.8 |
| Color | White |
8. Warranty and Customer Support
Hisense products are manufactured to the highest quality standards. For detailed warranty information, please refer to the warranty card included with your product or visit the official Hisense website.
If you experience any issues or have questions regarding your Hisense Portable Air Conditioner, please contact Hisense Customer Support:
- Website: www.hisense-canada.com/support (Example, please refer to your region's official website)
- Phone: Refer to your product documentation for regional support numbers.
- Please have your model number (AP14CR1SFTS00) and serial number ready when contacting support.