1. Introduction

The SINOTIMER MC901-611 is a universal intelligent temperature control meter designed for precise temperature regulation in various industrial and laboratory applications. This device features a clear LCD display, multiple input types, and reliable output options, making it suitable for a wide range of temperature control needs. This manual provides essential information for the safe and effective operation, installation, and maintenance of your MC901-611 temperature controller.

2. Safety Information

Please read this manual thoroughly before operating the device to ensure safe and correct usage. Keep this manual for future reference.

General Safety Precautions:

3. Product Overview

The MC901-611 temperature controller features a compact design with a clear digital display and intuitive control buttons.

Front view of the SINOTIMER MC901-611 temperature controller showing the PV and SV displays, indicator lights, and control buttons.

Figure 3.1: Front Panel
This image displays the front panel of the MC901-611. It features two digital displays: PV (Process Value) in red, showing the current temperature, and SV (Set Value) in green, showing the target temperature. Below the displays are indicator lights for OUT (Output), AT (Auto-tuning), ALM1 (Alarm 1), and ALM2 (Alarm 2). The control buttons include SET, R/S (Run/Stop), Down arrow, and Up arrow.

Key Components:

Side view of the SINOTIMER MC901-611 temperature controller showing the product label with specifications.

Figure 3.2: Side Panel with Specifications Label
This image shows the side of the MC901-611, highlighting the product label. The label provides crucial information such as Model (MC901-611), Input type (K, default setting), Temperature Range (0-1300°C), Temperature Unit (Celsius/Fahrenheit), Output type (Relay/SSR), Alarm (ALM1), Accuracy Class (0.5), and Power Supply (100-240V AC, 50/60Hz).

Rear view of the SINOTIMER MC901-611 temperature controller showing the wiring terminal block.

Figure 3.3: Rear Panel with Terminal Block
This image displays the rear of the MC901-611, featuring the terminal block for electrical connections. The terminals are clearly numbered, indicating where to connect power, sensor inputs, and control outputs. Proper wiring according to the provided diagram is essential for safe and correct operation.

4. Setup and Installation

4.1 Panel Mounting:

The MC901-611 is designed for panel mounting. Ensure the cutout dimensions in your panel match the device's specifications.

  1. Cut an opening in your panel according to the specified dimensions (refer to specifications section for exact size).
  2. Insert the MC901-611 into the panel cutout from the front.
  3. Attach the provided mounting brackets to the sides of the controller from the rear of the panel.
  4. Tighten the screws on the mounting brackets to secure the controller firmly in place. Do not overtighten.
Two black mounting brackets with screws for securing the temperature controller to a panel.

Figure 4.1: Mounting Brackets
This image shows the two mounting brackets included with the MC901-611. These brackets are used to secure the temperature controller firmly within a panel cutout, ensuring stable installation.

4.2 Wiring Diagram:

Refer to the wiring diagram on the side of the unit or in the detailed manual for correct connections. Ensure all connections are secure and insulated.

Note: A detailed wiring diagram is typically provided on the physical unit or in a separate wiring guide. Always consult the specific diagram for your model.

5. Operating Instructions

5.1 Power On:

Once wired correctly, apply power to the unit. The PV display will show the current temperature, and the SV display will show the last set temperature.

5.2 Setting the Target Temperature (SV):

  1. Press the SET button once. The SV display will start flashing.
  2. Use the Up () and Down () arrow buttons to adjust the target temperature.
  3. Press the SET button again to confirm the new SV and exit the setting mode. The SV display will stop flashing.

5.3 Parameter Settings:

To access advanced parameter settings (e.g., input type, control mode, alarm settings):

  1. Press and hold the SET button for approximately 3-5 seconds until the first parameter code appears on the PV display.
  2. Use the Up () and Down () arrow buttons to navigate through different parameter codes.
  3. Press SET to view the value of the currently displayed parameter.
  4. Use the Up () and Down () arrow buttons to change the parameter value.
  5. Press SET to confirm the new value and return to the parameter code display.
  6. To exit parameter setting mode, press and hold the SET button again for 3-5 seconds, or wait for the device to automatically exit after a period of inactivity.

Consult the full product manual for a complete list of parameter codes and their functions.

5.4 Auto-tuning (AT):

Auto-tuning helps the controller optimize its PID parameters for stable and accurate temperature control. This process is recommended after initial setup or if control performance is unsatisfactory.

  1. Set the desired target temperature (SV).
  2. Press and hold the R/S button for approximately 3-5 seconds. The AT indicator light will illuminate, and the controller will begin the auto-tuning process.
  3. Allow the auto-tuning process to complete. This may take some time as the controller cycles the output to learn the system's characteristics. The AT light will turn off once tuning is complete.
  4. Do not interrupt the auto-tuning process.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your MC901-611 temperature controller.

7. Troubleshooting

This section addresses common issues you might encounter with your MC901-611 temperature controller.

ProblemPossible CauseSolution
No display/Power offNo power supply; Loose wiring; Blown fuse.Check power connection; Verify wiring; Replace fuse if necessary (by qualified personnel).
PV display shows "HHHH" or "LLLL"Sensor open circuit (HHHH); Sensor short circuit or reverse connection (LLLL); Sensor type mismatch.Check sensor wiring and connections; Ensure correct sensor type is selected in parameters.
Temperature not controlled accuratelyIncorrect PID parameters; Sensor not properly installed; Load capacity mismatch.Perform auto-tuning; Ensure sensor is in good thermal contact with the process; Verify output capacity matches load.
Output indicator (OUT) not lighting upSV is equal to PV (no control action needed); Output wiring issue; Internal fault.Check SV and PV values; Inspect output wiring; If problem persists, contact support.

If the problem persists after attempting these solutions, please contact customer support.

8. Specifications

Technical specifications for the SINOTIMER MC901-611 Universal Intelligent Temperature Control Meter.

FeatureSpecification
ModelMC901-611
Input TypeK (default setting), Universal Input
Temperature Range0-1300°C (depending on sensor type)
Temperature UnitCelsius/Fahrenheit selectable
Output TypeRelay/SSR
AlarmALM1
Accuracy Class0.5
Power Supply100-240V AC, 50/60Hz
Display TypeLCD
Item Weight8.8 ounces
Package Dimensions4.3 x 4.3 x 3.6 inches

9. Warranty and Support

Warranty Information:

SINOTIMER products are typically covered by a limited warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or contact SINOTIMER customer service for specific warranty terms and conditions.

Customer Support:

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SINOTIMER customer support. Have your product model number (MC901-611) and purchase information ready when contacting support.

Contact information for SINOTIMER can usually be found on their official website or on the product packaging.

Related Documents - MC901-611

Preview SINOTIMER DDS6619 Series Guide Rail Metering Switch Instruction Manual
Instruction manual for SINOTIMER DDS6619 series guide rail type metering switches. Details technical specifications, wiring, app control via Smart Life/Tuya, operating instructions, and safety precautions for smart energy monitoring.
Preview MC-101 Series Intelligent Temperature Controller User Manual
User manual for the MC-101 Series Intelligent Temperature Controller, detailing its features, operation, and settings for precise temperature control.
Preview SINOTIMER SVP719 User Manual: Voltage Protector, Energy Meter, and Power Consumption Monitor
Comprehensive user manual for the SINOTIMER SVP719, detailing its features as an adjustable over/under voltage protector, surge protector, over-current limit relay, and a Watt/kWh energy meter for monitoring power consumption.
Preview Sinotimer MT-S PID Temperature Controller: Features, Specifications, and Setup Guide
Detailed information on the Sinotimer MT-S Intelligent PID Temperature Control Relay, including features, technical specifications, wiring diagrams, and setup instructions for PID and On-Off control modes.
Preview Siemens SIMODRIVE 611 universal Function Manual
A comprehensive function manual for Siemens SIMODRIVE 611 universal and SIMODRIVE 611 universal E drive systems, detailing product overview, installation, parameterization, commissioning, and diagnostics for advanced motion control applications.
Preview Siedle BGU 611-4/4-0 Flush-Mount Letterbox Housing Installation Guide
Comprehensive installation and mounting instructions for the Siedle BGU 611-4/4-0 flush-mount letterbox housing, including details on mounting without and with function modules, module removal, and lettering.