Product Overview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Key features include:

Setup and Preparation

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Image: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Operating Instructions

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Remove the protective cap from the electrode.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Clean the electrode thoroughly.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Troubleshooting

This section addresses common issues related to electrode performance and how the storage solution can help.

ProblemPossible CauseSolution
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Specifications

AttributeDetail
Product Name3M KCL Storage Soaking Solution
Model NumberAI1107
BrandApera Instruments
Item Volume8 Fluid Ounces (approx. 236 ml)
KCL Concentration3M (3 mol/L)
Item FormLiquid
Package InformationBottle
Product Dimensions6.3 x 1.97 x 2.36 inches
Item Weight9 Ounces
Country of OriginUSA

Warranty Information

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments website or contact their customer support directly.

Support and Contact

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments website:

www.aperainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Related Documents - AI1107

Preview Apera SX811-SS Portable pH Meter for Food Testing: Instruction Manual & Specifications
Comprehensive instruction manual and technical specifications for the Apera SX811-SS portable pH meter, designed for accurate food testing. Learn about features, calibration, setup, USB communication, and troubleshooting.
Preview PH60Z-HT Smart pH Meter User Manual - Apera Instruments
User manual for the Apera Instruments PH60Z-HT Smart pH Meter, detailing its features, operation, calibration, maintenance, and troubleshooting for high temperature and caustic solutions.
Preview PH60Z-PW Smart pH-Meter Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Smart pH-Meter. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen in reinem Wasser.
Preview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Preview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.
Preview APERA Instruments pH 4.00 Buffer Solution Safety Data Sheet
Safety Data Sheet (SDS) for APERA Instruments pH 4.00 Buffer Solution, providing essential information on identification, hazards, first aid, handling, storage, and regulatory compliance.