1. Introduction

This manual provides essential information for the safe and efficient operation of your Aclorol 5V 20A 100W Switching Power Supply. This device converts 110V/220V AC input to a stable 5V DC output, suitable for various applications such as WS2811/2801/WS2812B/WS2813 LED strip pixel lights, CCTV cameras, security systems, and computer projects.

Please read these instructions carefully before installation and use, and retain them for future reference.

2. Safety Information and Warnings

  • Indoor Use Only: This power supply is designed for indoor use exclusively. Do not expose it to moisture or outdoor elements.
  • Input Voltage Selection: Before connecting the power supply to an AC source, ensure the 110V/220V switch is set correctly for your region. For the USA, set the switch to 110V. Incorrect voltage selection can cause severe damage to the unit and connected devices. The switch is located inside the cover.
  • Professional Installation Recommended: Wiring should be performed by qualified personnel to prevent electrical shock or damage.
  • Ventilation: Ensure adequate ventilation around the power supply. The metal case with perforations is designed for efficient heat dissipation. Do not obstruct ventilation holes.
  • Overload Protection: Do not exceed the maximum output of 5V 20A (100W). Overloading can trigger protection mechanisms or damage the unit.
  • Protection Features: The unit includes Over-voltage Protection, Overload Protection, Overheating Protection, and Short Circuit Prevention.
  • Voltage Adjustment: The output voltage can be adjusted by approximately 15% using the +V ADJ potentiometer. Adjust carefully with a multimeter to avoid over-voltage to connected devices.
Aclorol 5V 20A 100W Switching Power Supply with 110V/220V switch highlighted.

Image: Top view of the power supply showing the input voltage selection switch (110V/220V). Always verify this setting before use.

Internal components of the Aclorol 5V 20A 100W Switching Power Supply, illustrating the 7-Point Safety System.

Image: Internal view of the power supply, highlighting its 7-Point Safety System, including short circuit, electromagnetic wave, overcurrent, over temperature, over voltage protection, and quality microchip.

3. Product Features

  • Input: AC 110V/220V (selectable) 50/60Hz.
  • Output: DC 5V, 20A maximum, 100W.
  • Adjustable Output Voltage: Output voltage can be adjusted by approximately 15% using the +V ADJ potentiometer.
  • Dual Output Channels: Features 2 sets of output channels for flexible connectivity.
  • High-Quality Components: Constructed with pure copper inductors, high-performance transformers, and dual-capacity electrolytic capacitors for stable and reliable power delivery.
  • Comprehensive Protection: Includes Over-voltage Protection, Overload Protection, Overheating Protection, and Short Circuit Prevention.
  • Efficient Heat Dissipation: Metal case with numerous ventilation holes ensures effective cooling without the need for an internal fan, resulting in silent operation.
  • Wide Application: Ideal for WS2811/2801/WS2812B/WS2813 LED strip pixel lights, CCTV cameras, security systems, computer projects, and other 5V power supply applications.

4. Specifications

ParameterValue
BrandAclorol
Model NumberYC-5V20A-SL
Input VoltageAC 110V/220V (selectable)
Output VoltageDC 5V
Output Current20 Amps (max)
Output Wattage100 Watts (max)
Frequency50/60Hz
Enclosure MaterialMetal
Working Temperature-10 to 50 degrees Celsius
Storage Temperature-20 to 60 degrees Celsius
Environmental Humidity10-95%
Safety ComplianceCCC/ FCC / CE
Dimensions (Approx.)20cm (7.8in) L x 10cm (3.9in) W x 4.2cm (1.6in) H
Aclorol 5V 20A 100W Switching Power Supply dimensions: 20cm (7.8in) length, 10cm (3.9in) width, 4.2cm (1.6in) height.

Image: Product dimensions of the Aclorol 5V 20A 100W Switching Power Supply.

5. Setup and Installation

5.1 Input Voltage Selection

Before connecting the power supply, verify the input voltage switch setting. This switch is located on the side of the unit, often visible through the perforated casing. Ensure it matches your local AC mains voltage (e.g., 110V for North America, 220V for Europe). Failure to do so will damage the unit.

5.2 Wiring Connections

The power supply features clearly labeled screw terminals for AC input and DC output. Refer to the diagram below for correct wiring.

Wiring diagram for Aclorol 5V 20A 100W Switching Power Supply. Terminals are labeled L (AC Live), N (AC Neutral), GND (Ground), -V (DC 5V-), -V (DC 5V-), +V (DC 5V+), +V (DC 5V+), +V ADJ (Adjust output voltage).

Image: Detailed wiring diagram showing terminal connections for AC input and DC output.

  1. AC Input (110V/220V):
    • Connect the AC Live wire to the terminal labeled L.
    • Connect the AC Neutral wire to the terminal labeled N.
    • Connect the Ground wire to the terminal labeled with the GND symbol (⏚).
  2. DC Output (5V):
    • Connect the positive (+) lead of your 5V device to the terminals labeled +V. There are two +V terminals provided.
    • Connect the negative (-) lead of your 5V device to the terminals labeled -V (or COM). There are two -V terminals provided.
  3. Voltage Adjustment: The +V ADJ terminal is a potentiometer for fine-tuning the output voltage. Use a small screwdriver to adjust it within approximately 15% of 5V. Always use a multimeter to verify the output voltage before connecting sensitive devices.

Note: Power cords and extension wires are not included with this product. You will need to provide your own appropriate wiring.

Close-up of the Aclorol 5V 20A 100W Switching Power Supply terminals with red and black wires connected, and a note indicating power cords are not included.

Image: Example of wiring connections to the power supply terminals. Note that power cords are not supplied.

6. Operating Instructions

  1. Initial Check: Before powering on, double-check all wiring connections and ensure the input voltage switch is correctly set.
  2. Power On: Connect the AC input to a suitable power source. The indicator light on the unit should illuminate, indicating power is supplied.
  3. Voltage Verification: It is recommended to measure the output voltage with a multimeter at the +V and -V terminals to confirm it is stable at 5V before connecting your devices.
  4. Connecting Devices: Once the output voltage is verified, connect your 5V devices to the +V and -V terminals. Ensure the total current draw does not exceed 20A.
  5. Voltage Adjustment (if needed): If a slight voltage adjustment is required, carefully turn the +V ADJ potentiometer with a small insulated screwdriver while monitoring the output with a multimeter.
Aclorol 5V 20A 100W Switching Power Supply connected to various 5V devices like LED strips, CCTV cameras, speakers, and computers, demonstrating universal compatibility.

Image: The power supply demonstrating universal compatibility with various 5V devices.

7. Maintenance

  • Cleaning: Keep the power supply clean and free from dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Regularly check that the ventilation holes on the metal casing are not blocked to ensure proper heat dissipation.
  • Environmental Conditions: Operate the unit within the specified working temperature and humidity ranges to ensure longevity.
  • No User-Serviceable Parts: Do not attempt to open or repair the power supply. There are no user-serviceable parts inside. Opening the unit may void the warranty and expose you to dangerous voltages.

8. Troubleshooting

ProblemPossible CauseSolution
No output voltage / Indicator light off
  • No AC input power.
  • Incorrect input voltage switch setting.
  • Loose wiring connections.
  • Internal fault.
  • Check AC power source and cable.
  • Verify 110V/220V switch setting.
  • Tighten all screw terminals.
  • If problem persists, contact support.
Output voltage unstable or incorrect
  • Overload condition.
  • +V ADJ potentiometer misadjusted.
  • Faulty connected device.
  • Reduce load to within 20A.
  • Adjust +V ADJ potentiometer carefully with a multimeter.
  • Disconnect devices one by one to identify faulty unit.
Unit gets excessively hot
  • Insufficient ventilation.
  • Overload condition.
  • Ensure clear space around the unit for airflow.
  • Reduce connected load.

9. Warranty and Support

This Aclorol Switching Power Supply comes with a 24-month warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact Aclorol customer service through the retailer where the product was purchased or visit the official Aclorol store page on Amazon: Aclorol Store.

Related Documents - YC-5V20A-SL

Preview TOA Audio & Intercom Product Catalogue: Professional Sound Solutions
Explore the comprehensive TOA Audio & Intercom Product Catalogue, featuring over 90 years of expertise in commercial and professional audio equipment. Discover solutions for public address, voice communications, voice evacuation, and more.
Preview Gogogate 2 Camera List 2015: Verified IP Camera Compatibility
Explore the comprehensive Gogogate 2 camera compatibility list for 2015, featuring verified and non-tested IP camera models from leading brands. Find compatible cameras for your security system.
Preview Meling Biomedical Pharmacy/Medical Refrigerator Operation Manual
Operation manual for Meling Biomedical Pharmacy/Medical Refrigerators. Includes installation, safety instructions, operation, maintenance, and technical specifications for models YC-55L through YC-1505L.
Preview Meling Biomedical Pharmacy/Medical Refrigerator Operation Manual
Comprehensive operation manual for Meling Biomedical pharmacy and medical refrigerators, covering safety instructions, installation, operation, maintenance, and troubleshooting for models YC-55L through YC-1505L.
Preview MELING Biomedical Pharmacy/Medical Refrigerator Operation Manual
This operation manual provides detailed instructions for the safe and effective use, installation, maintenance, and troubleshooting of MELING Biomedical Pharmacy/Medical Refrigerators. It covers various models and includes safety precautions, operating procedures, and technical specifications.
Preview YC & Mate Machinery Oil-Free Vacuum Pump Instruction Manual
Comprehensive instruction manual for YC & Mate Machinery oil-free vacuum pumps. Includes installation steps, technical parameters, maintenance guidelines, and troubleshooting for various models.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.