SKF TKSA 71
SKF TKSA 71 Professional Wireless Laser Shaft Alignment System
User Manual
1. Introduction
The SKF Shaft Alignment Tool TKSA 71 is engineered for precise shaft alignment in demanding industrial environments. This instrument provides advanced features for alignment professionals and complex applications, while its intuitive application interface ensures ease of use and efficient shaft alignment procedures.
The TKSA 71 is highly versatile, featuring ultra-compact measuring units suitable for use in confined spaces. Its specialized software applications facilitate convenient alignment across various applications, including horizontal and vertical shafts, spacer shafts, and machine trains. This product is classified as a Class II Laser Product with a laser capacity below 1mW.
Key Features:
- Superior Alignment Performance: Offers up to 10 m measurement distance, disturbance compensation, measurement flexibility, only 40° total rotation required, automatic measurement, and customized alignments with target values.
- Protection Against Harsh Environments: Features completely sealed measuring units (IP67) designed to resist dust and water ingress.
- Wide Range of Applications: Supported by comprehensive accessories and dedicated software applications for diverse alignment tasks.
- Easy-to-Use Interface: Incorporates intuitive software applications, guided alignment processes, and explanatory videos for user convenience.
- Ultra-Compact Measuring Units: Designed for effective use in extremely narrow operational spaces.
- Laser Classification: Class II Laser Product with a laser capacity below 1mW.
2. Setup
Proper setup of the SKF TKSA 71 system is crucial for accurate alignment results. Follow these general steps for initial deployment:
- Unpack Components: Carefully remove all components from the carrying case, including the measuring units, display unit (tablet), and mounting hardware.
- Charge Devices: Ensure both measuring units and the display unit are fully charged before use. Connect them to their respective power adapters if necessary.
- Install Software: If not pre-installed, download and install the SKF TKSA 71 alignment application on your compatible tablet or smartphone.
- Mount Measuring Units: Attach the measuring units to the shafts of the machinery to be aligned using the provided mounting brackets. Ensure they are securely fastened and positioned correctly according to the application's requirements.
- Power On and Connect: Power on the measuring units and the display unit. Establish a wireless connection between the units and the application. Refer to the in-app instructions for specific pairing procedures.
- Initial Calibration/Check: Perform any initial calibration or system checks as prompted by the software to ensure all sensors are functioning correctly.
Figure 1: Engineer using SKF TKSA 71 system to align a motor and pump shaft. This image shows an engineer performing shaft alignment using the SKF TKSA 71 system. The system's measuring units are attached to the shafts, and the engineer is interacting with the alignment software on a tablet device.
3. Operating Instructions
The SKF TKSA 71 system is designed for intuitive operation through its dedicated software application. The following outlines the general workflow for performing shaft alignment:
- Select Application Mode: Open the SKF TKSA 71 application and select the appropriate alignment mode (e.g., horizontal, vertical, spacer shaft, machine train) based on your machinery configuration.
- Input Machine Dimensions: Enter the required machine dimensions into the application, such as coupling diameter, distance between measuring units, and distances to the machine's feet.
- Perform Measurement: Follow the on-screen instructions to rotate the shafts and take measurements. The system requires only 40° total rotation for accurate data acquisition. The application provides real-time feedback and guidance.
- Analyze Results: Once measurements are complete, the application will display the current alignment status, indicating any misalignment in both horizontal and vertical planes.
- Adjust Machinery: The software will provide clear, guided instructions on how to adjust the machinery (e.g., adding or removing shims, moving the machine horizontally) to achieve optimal alignment. The system supports customized alignments with target values.
- Verify Alignment: After adjustments, perform a final measurement to verify that the alignment is within acceptable tolerances. The application can generate reports for documentation.
4. Maintenance
To ensure the longevity and accuracy of your SKF TKSA 71 system, regular maintenance is recommended:
- Cleaning: After each use, especially in harsh environments, wipe down the measuring units and other components with a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Storage: Store all components in their original carrying case in a dry, temperature-controlled environment when not in use.
- Battery Care: For optimal battery life, avoid fully discharging the units frequently. Charge them regularly, even during periods of non-use.
- Software Updates: Periodically check for and install software updates for the SKF TKSA 71 application. Updates often include performance improvements, new features, and bug fixes.
- Inspection: Regularly inspect cables, connectors, and mounting hardware for any signs of wear or damage. Replace damaged components immediately.
- Environmental Protection: While the measuring units are IP67 rated for dust and water resistance, prolonged exposure to extreme conditions should be avoided.
5. Troubleshooting
This section provides general guidance for common issues encountered with the SKF TKSA 71 system. For more detailed troubleshooting, refer to the in-app help or contact SKF support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Units not connecting wirelessly. | Bluetooth disabled, units out of range, low battery, interference. | Ensure Bluetooth is enabled on both devices. Bring units closer. Charge batteries. Reduce electromagnetic interference. Restart units and application. |
| Inaccurate measurement readings. | Loose mounting, dirty lenses, excessive vibration, incorrect machine dimensions. | Verify units are securely mounted. Clean laser lenses. Minimize external vibrations. Double-check entered machine dimensions. |
| Application crashes or freezes. | Outdated software, insufficient device memory, software bug. | Update the application to the latest version. Close other applications on the device. Restart the application or device. |
| Units not powering on. | Depleted battery, faulty charging cable/adapter. | Charge units for an extended period. Try a different charging cable or adapter. |
6. Specifications
| Attribute | Detail |
|---|---|
| Model Number | TKSA 71 |
| Manufacturer | SKF |
| ASIN | B07JZGW1G7 |
| First Available Date | December 10, 2019 |
| Laser Classification | Class II Laser Product (below 1mW) |
| Ingress Protection (Measuring Units) | IP67 (Dust and Water Resistant) |
| Measurement Distance | Up to 10 meters |
| Minimum Rotation for Measurement | 40° total rotation |
7. Warranty and Support
For information regarding the warranty of your SKF TKSA 71 system, please refer to the documentation included with your purchase or visit the official SKF website. SKF provides comprehensive support for its products.
If you encounter any issues not covered in this manual or require technical assistance, please contact SKF customer support. You can often find contact details on the SKF official website or through the product application.
Figure 2: QR code for SKF TKSA 71 product information. This QR code provides a quick link to additional product information and resources for the SKF TKSA 71 system. Scan this code with your smartphone or tablet to access the official product page or support resources.
Alternatively, visit the official product page: SKF TKSA 71 Product Information
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.