Lifebreath CAF
CAF Series Clean Air Furnace User Manual
Introduction
Welcome to the user manual for your new Lifebreath CAF Series Clean Air Furnace. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your unit. Please read this manual thoroughly before operating the appliance.

A white, rectangular Lifebreath CAF Series Clean Air Furnace unit with blue circular ports on the right side, designed for air purification and circulation.
Important Safety Information
- Read all instructions before installation and operation.
- Disconnect power before servicing or cleaning.
- Ensure proper ventilation during operation.
- Do not block air inlets or outlets.
- Only qualified personnel should perform installation and major repairs.
- Keep children and pets away from the unit during operation.
Setup and Installation
Unpacking
- Carefully remove the furnace from its packaging.
- Inspect the unit for any shipping damage. Report any damage to your supplier immediately.
- Ensure all components listed in the packing list are present.
Installation Location
- Choose a location that allows for adequate airflow and easy access for maintenance.
- The unit should be installed on a level, stable surface.
- Maintain minimum clearances around the unit as specified in local building codes.
Ducting Connections
- Connect appropriate ductwork to the inlet and outlet ports of the furnace.
- Ensure all connections are sealed to prevent air leaks.
- Refer to the installation diagram for correct ducting configuration.
Electrical Connection
- All electrical wiring must comply with local and national electrical codes.
- Connect the unit to a dedicated power supply as specified on the product label.
- Ensure the unit is properly grounded.
Operating Instructions
Initial Startup
- After installation, ensure all connections are secure and power is off.
- Turn on the power supply to the unit.
- The unit should begin operation automatically or can be controlled via an external thermostat/controller.
Normal Operation
- The CAF Series Clean Air Furnace is designed to continuously filter and circulate air.
- Monitor the indicator lights for operational status.
- Adjust settings as needed through your home's thermostat or dedicated control panel.
Maintenance
Filter Replacement
The CAF Series Clean Air Furnace utilizes high-efficiency filters (Polyester, Fiberglass) that require periodic replacement to maintain optimal performance.
- Frequency: Filters should be inspected monthly and replaced every 3-6 months, or more frequently in dusty environments.
- Procedure:
- 1. Disconnect power to the unit.
- 2. Open the filter access panel.
- 3. Remove the old filter, noting its orientation.
- 4. Insert a new, clean filter (Part Number: 99-BC03) with the correct airflow direction.
- 5. Close the access panel and restore power.
General Cleaning
- Wipe down the exterior of the unit with a soft, damp cloth as needed.
- Do not use abrasive cleaners or solvents.
- Ensure air vents are free from dust and debris.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | No power supply; tripped circuit breaker; loose wiring. | Check power connection; reset breaker; inspect wiring (call technician if unsure). |
| Reduced airflow | Clogged filter; blocked ducts. | Replace filter; check ducts for obstructions. |
| Unusual noise | Loose components; motor issue. | Ensure all panels are secure; contact customer support if noise persists. |
Specifications
| Feature | Detail |
|---|---|
| Brand | Lifebreath |
| Model | CAF |
| Part Number | 99-BC03 |
| Compatible Device | Furnace |
| Material Type | Polyester, Fiberglass |
| UPC | 653958802662 |
| First Available | November 21, 2019 |
Warranty and Support
Lifebreath products are manufactured to the highest quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Lifebreath website.
For technical support, service, or replacement parts, please contact Lifebreath customer service. Have your model number (CAF) and part number (99-BC03) ready when contacting support.
Online Support: www.lifebreath.com
Customer Service: Refer to your product documentation for regional contact information.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.