DISONCARE Odyssey 60H

DISONCARE Odyssey 60H Insulin Cooler Travel Case Instruction Manual

Model: Odyssey 60H

Brand: DISONCARE

1. Introduction

The DISONCARE Odyssey 60H Insulin Cooler Travel Case is designed to maintain the required temperature for temperature-sensitive medications, such as insulin pens and vials, during travel and outdoor activities. This manual provides essential information on how to properly use and care for your cooler to ensure the safety and efficacy of your medication.

2. Product Overview

The Odyssey 60H cooler features a double-layered vacuum insulated stainless steel body, providing robust temperature retention. It includes a primary blue gel bottle for extended cooling and an emergency white bottle for temporary cooling when freezing is not an option. The cooler is equipped with a temperature display for monitoring and protective sleeves for your medication.

DISONCARE Odyssey 60H Insulin Cooler with QR code and pens inside

Image: The DISONCARE Odyssey 60H Insulin Cooler in blue, showing the exterior with a QR code and the interior containing insulin pens and the blue gel bottle.

3. Setup & Preparation

3.1 Preparing the Blue Gel Bottle (Primary Cooling)

  1. Place the blue gel bottle in a freezer for 6-8 hours until completely frozen.
  2. After freezing, remove the bottle from the freezer and let it sit at room temperature for 5-30 minutes before placing it into the cooler. This allows the gel to temper slightly, preventing medication from freezing.

3.2 Preparing the White Emergency Bottle (Temporary Cooling)

  1. If a freezer is unavailable, fill the white emergency bottle with cold water.
  2. Place the filled emergency bottle into the cooler. This provides temporary cooling for approximately 12 hours.
Instructions for preparing the blue gel bottle and emergency bottle, along with a cooler performance table.

Image: Visual instructions for freezing the blue gel bottle and filling the white emergency bottle with cold water. A table details cooling performance based on outside temperature.

4. Operating Your Cooler

4.1 Inserting Medication

  • Place your insulin pens or vials into the provided protective sleeves. This prevents direct contact with the cold bottle and provides cushioning.
  • Carefully insert the sleeved medication into the cooler alongside the prepared cooling bottle (blue gel or white emergency).
  • Securely close the cooler lid.

4.2 Capacity

The Odyssey series cooler is designed to hold 2-3 injection pens. It can also accommodate approximately 22 x 3ml vials or 4 x 10ml vials, depending on their specific dimensions. Refer to the compatibility charts for common injection pen models.

Diagram showing the dimensions of the Odyssey series cooler and its capacity for pens and vials.

Image: A diagram illustrating the internal dimensions of the Odyssey cooler and its capacity for 3 pens, 22 x 3ml vials, or 4 x 10ml vials.

Compatibility chart for Eli Lilly and Novo Nordisk insulin pens.

Image: A detailed chart indicating the quantity of various Eli Lilly and Novo Nordisk injection pens that can be stored in the cooler.

Compatibility chart for other brands of insulin pens and vials.

Image: A detailed chart indicating the quantity of various other brands of injection pens and vials that can be stored in the cooler.

4.3 Temperature Monitoring

The cooler features a built-in thermometer on the lid to display the internal temperature. This allows for quick and accurate temperature checks without opening the cooler, ensuring your medication remains within the safe range.

Close-up of the cooler's lid showing the integrated thermometer display.

Image: A close-up view of the cooler's lid, highlighting the digital temperature display for easy monitoring.

5. Travel Guidelines (TSA Approved)

The DISONCARE Odyssey 60H cooler is TSA approved for air travel. To ensure a smooth security check, follow these steps:

  1. Keep the blue gel bottle frozen and store your insulin and cooler in an easily accessible location in your carry-on bag.
  2. Carry a doctor's prescription or a medical certificate stating your need to travel with insulin and the cooler.
  3. Proactively inform the TSA agent that you are carrying medically necessary insulin and a cooler.

Video: An official DISONCARE video demonstrating the Odyssey Series cooler and highlighting its TSA approval for travel.

6. Medical Alert QR Code

The cooler features a unique QR code for medical alert and loss prevention. By scanning the QR code, you can register and upload important medical information, emergency contacts, and photos. This information can be accessed by rescuers or good Samaritans in case of an emergency or if the cooler is lost, helping to ensure your safety and the return of your medication.

  • Registration: Scan the QR code on your cooler to register your device and create your medical profile.
  • Information: Upload critical medical details, including your condition, medication, and emergency contact numbers.
  • Privacy: You can set privacy controls to restrict viewing of sensitive contact information.
A smartphone displaying the medical alert information after scanning the QR code on the cooler.

Image: A smartphone screen showing the medical alert profile accessible by scanning the QR code on the cooler, including emergency contact details.

For more information or to manage your medical ID, visit: disontag.com/418309865

7. Care & Maintenance

  • Clean the interior and exterior of the cooler with a soft, damp cloth. Do not use abrasive cleaners or harsh chemicals.
  • Ensure the cooler is completely dry before storing.
  • Store the cooler in a cool, dry place away from direct sunlight.
  • Do not open or consume the contents of the gel bottles.

8. Specifications

FeatureDetail
Model NumberPR-COM-RT-X1081581
Product Dimensions2.5 x 2.5 x 9 inches
Item Weight1.32 Pounds
Material18/8 (304) Food-Grade Stainless Steel (Inner & Outer Layers), Double-Layered Vacuum Insulation
Cooling Duration (Blue Gel)Up to 48 hours (in 86°F/30°C outdoor environment)
Cooling Duration (Emergency Bottle)Extends cooling by 12 hours
Capacity (Odyssey Series)2-3 Insulin Pens, or 22 x 3ml vials, or 4 x 10ml vials
Special FeaturesIntegrated Temperature Display, TSA Approved, QR Medical Alert Tag

9. Troubleshooting

If you experience issues with your DISONCARE Odyssey 60H cooler, consider the following:

  • Insufficient Cooling: Ensure the blue gel bottle was frozen for the recommended 6-8 hours and allowed to temper for 5-30 minutes before use. Verify the lid is securely closed.
  • Medication Freezing: If medication appears frozen, reduce the tempering time of the blue gel bottle before placing it in the cooler. Always use the protective sleeves.
  • Temperature Display Inaccuracy: If you suspect the temperature display is inaccurate, compare it with an external thermometer. Ensure the cooler is not exposed to extreme external temperatures for prolonged periods.

10. Support

For further assistance, product inquiries, or to manage your QR Medical Alert ID, please visit the official DISONCARE website or contact customer support through the information provided on your QR tag.

Manufacturer: Zhengzhou Dison Electric CO.,LTD.

Video: An official DISONCARE video demonstrating how to use the insulin cooler, including preparation and insertion of medication.

Video: A user review of the DISONCARE portable insulin cooler, demonstrating its features and ease of use for medication storage.

Related Documents - Odyssey 60H

Preview HLG-60H Series 60W Constant Voltage + Constant Current LED Driver Specification
Technical specification and user manual for the MEAN WELL HLG-60H series 60W LED driver, featuring constant voltage and constant current modes, IP67/IP65 rating, and various dimming options.
Preview MEAN WELL HLG-60H Series: 60W Constant Voltage/Current LED Driver Specifications
Detailed specifications for the MEAN WELL HLG-60H series 60W LED drivers, featuring constant voltage and constant current output, IP65/IP67 rating, wide operating temperature, and various dimming options for diverse lighting applications.
Preview MEAN WELL HLG-60H Series: 60W Constant Voltage + Constant Current LED Driver
Explore the MEAN WELL HLG-60H series, a 60W AC/DC LED driver offering dual-mode constant voltage and constant current output. Features include high efficiency, IP67/IP65 rating, wide operating temperature, and various dimming options for diverse LED lighting applications.
Preview MEAN WELL HLG-60H Series: 60W Constant Voltage/Current LED Driver Specifications
Detailed technical specifications, features, applications, and performance data for the MEAN WELL HLG-60H series 60W Constant Voltage and Constant Current LED drivers, suitable for various lighting applications.
Preview 1999-2004 Honda Odyssey Thermostat Replacement Guide
Step-by-step instructions for replacing the thermostat in a 1999-2004 Honda Odyssey 3.5L V6. This guide details the necessary tools and parts for the repair.
Preview SAMSUNG 顯示器 使用者指南:型號與操作說明
本使用者指南提供 SAMSUNG 顯示器型號的詳細操作說明、安裝指南、連接方法、疑難排解與規格資訊,幫助使用者充分利用其顯示器功能。

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.