1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the FAAC Lecteur Autonomo Resist Tps Sa. This autonomous reader is designed for secure access control applications, typically used with gate or door automation systems. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. Safety Information
- Installation must be performed by qualified personnel in accordance with local electrical codes and regulations.
- Disconnect power to the access control system before performing any installation, maintenance, or wiring procedures.
- Do not expose the device to extreme temperatures, moisture, or corrosive substances.
- Ensure all connections are secure and properly insulated to prevent short circuits.
- Keep packaging materials out of reach of children.
3. Package Contents
Verify that all components are present before beginning installation:
- FAAC Lecteur Autonomo Resist Tps Sa unit
- Mounting screws and anchors (typically included)
- Wiring terminals (if applicable)
4. Setup and Installation
4.1 Component Overview

Image 1: Front view of the FAAC Lecteur Autonomo Resist Tps Sa. The unit features a numeric keypad (0-9), 'X' for clear/cancel, and 'E' for enter/confirm. The FAAC logo is centrally located, and small indicator lights are visible above it.
4.2 Mounting the Unit
- Choose a suitable mounting location near the access point, ensuring it is protected from direct heavy rain and easily accessible.
- Mark the drilling points on the wall using the unit's backplate as a template.
- Drill holes and insert appropriate wall anchors.
- Secure the unit to the wall using the provided screws.
4.3 Wiring Connections
Refer to the wiring diagram provided with your specific gate/door automation system for detailed connections. General wiring steps include:
- Connect the power supply (typically 12-24V AC/DC) to the designated terminals on the reader.
- Connect the output terminals of the reader to the control input of your gate or door opener. This output typically triggers the opening mechanism upon successful code entry.
- Ensure all connections are tight and insulated.
4.4 Initial Programming
The initial programming involves setting up master codes and user access codes. Consult the specific programming instructions that came with your unit, as procedures can vary slightly by firmware version. Typically, this involves:
- Entering a default master code to access programming mode.
- Adding new user codes (e.g., 4-8 digits long).
- Exiting programming mode to save changes.
5. Operation
5.1 Entering an Access Code
To activate the access control system:
- Press the numeric keys to enter your valid access code.
- Press the 'E' (Enter) button to confirm the code.
- If the code is correct, the indicator light will typically illuminate green, and the gate/door will activate.
5.2 Correcting an Entry
If you make a mistake while entering the code, press the 'X' (Clear) button to clear the current entry and re-enter the code.
5.3 Indicator Lights
The small indicator lights above the FAAC logo provide feedback:
- Green Light: Indicates a valid code entry and successful activation.
- Red Light: Indicates an invalid code entry or an error.
- Amber/Yellow Light: May indicate programming mode or a specific status depending on the model.
6. Maintenance
- Cleaning: Clean the keypad surface periodically with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Inspection: Regularly inspect the unit for any signs of damage, loose connections, or wear.
- Firmware Updates: If applicable, consult FAAC support for information on firmware updates.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on. | No power supply or incorrect wiring. | Check power connections and ensure correct voltage. Verify wiring to the power source. |
| Code entered, but gate/door does not open. | Incorrect code, output wiring issue, or gate/door opener fault. | Ensure the correct code is entered. Check wiring between the reader and the gate/door opener. Test the gate/door opener independently. |
| Red indicator light illuminates after code entry. | Invalid access code. | Re-enter the correct access code. If the issue persists, verify the code in programming mode. |
| Buttons are unresponsive. | Physical damage or internal fault. | Inspect for visible damage. If unresponsive, contact FAAC support for assistance. |
8. Specifications
- Brand: FAAC
- Model Number: 403139
- Product Type: Autonomous Reader
- Package Weight: 500 g
- Package Dimensions: 100.0 L x 100.0 H x 50.0 W (millimeters)
- ASIN: B07GZ16ZXH
9. Warranty Information
Information regarding the warranty for the FAAC Lecteur Autonomo Resist Tps Sa is not available in the provided product details. Please refer to your purchase documentation or contact your retailer or FAAC directly for warranty terms and conditions.
10. Support and Contact
For further assistance, technical support, or inquiries regarding your FAAC Lecteur Autonomo Resist Tps Sa, please contact FAAC customer service or your authorized FAAC dealer. You can typically find contact information on the official FAAC website (www.faac.com).