1. Introduction
Thank you for choosing the Rossmax Swiss Design X5 Automatic Blood Pressure Monitor. This device is designed for accurate and reliable measurement of blood pressure and pulse rate at home. It incorporates advanced PARR (Pulse Arrhythmia) technology for early detection of Atrial Fibrillation (AFib), Premature Contraction (PC), Tachycardia, and Bradycardia during regular blood pressure checks. Please read this manual thoroughly before use to ensure proper operation and to maximize the benefits of this device.
2. Safety Information
Important: Always consult your physician for diagnosis and treatment. Self-diagnosis and treatment based on measurement results can be dangerous.
- This device is intended for adult use only.
- Do not use this device on infants, toddlers, or children.
- Do not use this device for any purpose other than measuring blood pressure.
- Keep the device and cuff out of reach of children.
- Do not disassemble or attempt to repair the device.
- Cardiac disorders require medical attention. The PARR technology assists in early diagnosis by detecting arrhythmia during blood pressure checks without additional user interaction or measurement prolongation.
- If you experience any discomfort during measurement, press the power button to immediately stop the inflation.
3. Components Overview
The Rossmax X5 Blood Pressure Monitor package includes the following components:
- Rossmax X5 Main Unit
- Universal Cone Cuff (24-40cm)
- Instruction Manual (this document)
- 4 x AA Batteries (included)

Figure 3.1: Front view of the Rossmax X5 Automatic Blood Pressure Monitor, showing the digital display, control buttons, and connected cuff.

Figure 3.2: The Universal Cone Cuff (24-40cm) included with the Rossmax X5 monitor.
4. Setup
4.1 Battery Installation
- Open the battery cover on the back of the unit.
- Insert four (4) AA size batteries according to the polarity indicators (+ and -) inside the compartment.
- Close the battery cover securely.
Note: The device can also be powered by an optional AC adaptor (not included).

Figure 4.1: Side view of the monitor, indicating the 6V DC power input and DATA port.

Figure 4.2: A closer look at the 6V DC power input and DATA port for optional connectivity.
4.2 Cuff Connection
Insert the air plug of the cuff firmly into the air jack on the left side of the monitor. Ensure a secure connection to prevent air leakage during measurement.
5. Operating Instructions
5.1 Before Measurement
- Avoid eating, drinking alcohol, smoking, and exercising for at least 30 minutes before measurement.
- Rest for at least 5 minutes before taking a measurement.
- Sit upright with your back supported and feet flat on the floor.
- Place your arm on a table so the cuff is at heart level.
- Ensure the cuff is applied directly to your bare arm, not over clothing.
5.2 Applying the Cuff
- Slide the end of the cuff through the metal ring to form a loop. The smooth cloth should be on the inside of the cuff loop.
- Place the cuff on your left upper arm so that the air tube runs down the inside of your arm.
- The bottom edge of the cuff should be approximately 2-3 cm (0.8-1.2 inches) above your elbow.
- Wrap the cuff snugly around your arm. Ensure it is not too tight or too loose.
5.3 Taking a Measurement
- Press the Power button to turn on the monitor.
- The cuff will automatically inflate. Remain still and silent during the measurement.
- Once the measurement is complete, the monitor will display your Systolic (SYS), Diastolic (DIA) blood pressure, and Pulse rate.
- The display will also show indicators for PARR technology (ARR/AFib/PC) if detected.
- The measurement will be automatically stored in the device's memory.
- The device will auto-shut-off approximately 1 minute after the last key operation.
5.4 Understanding Display Indicators
- SYS: Systolic blood pressure (upper value).
- DIA: Diastolic blood pressure (lower value).
- PULSE /min: Your pulse rate in beats per minute.
- ARR: Arrhythmia detection.
- AFib: Atrial Fibrillation detection.
- PC: Premature Contraction detection.
- M: Memory indicator. The device stores 60 memories for each of two zones.
6. Maintenance
6.1 Cleaning
- Clean the monitor and cuff with a soft, dry cloth.
- Do not use abrasive cleaners or immerse the device in water.
6.2 Storage
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display when powered on | Batteries are dead or incorrectly inserted. | Replace batteries or check polarity. |
| Cuff does not inflate or inflates weakly | Cuff not connected properly or air leakage. | Ensure cuff air plug is firmly inserted. Check cuff for damage. |
| Inaccurate readings | Improper cuff placement, movement during measurement, or incorrect posture. | Re-apply cuff correctly, remain still and silent, ensure proper posture. |
| Error message on display | Refer to the specific error code in the full manual (if available) or contact support. | Repeat measurement after resting. If error persists, contact customer support. |
For further assistance, please contact Rossmax customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Measurement Range (Pressure) | 30~260 mmHg |
| Measurement Range (Pulse) | 40~199 beats/minute |
| Accuracy (Pressure) | ± 3 mmHg |
| Accuracy (Pulse) | ± 5% of reading |
| Memory Capacity | 60 memories for each zone x 2 zones |
| Deflation | Automatic Air Release Valve |
| Auto-shut-off | 1 minute after last key operation |
| Manufacturer | Rossmax |
| Country of Origin | China |
| Product Dimensions | 16.5 x 14 x 8 cm |
| Item Weight | 0.45 g |
| Power Source | Battery Powered, Adaptor facility |
| Display Type | Digital |
| Included Components | Cuff |
| Batteries | 2 AA batteries required (included) |
9. Warranty and Support
The Rossmax X5 Automatic Blood Pressure Monitor comes with a 5-year lifetime calibration warranty. For any product-related queries, technical support, or warranty claims, please contact Rossmax customer support.
Rossmax Customer Support Number: 8884555054