1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Commercial Electric 15-inch 22.5-Watt Dimmable LED Round Flat Panel Ceiling Flushmount with Color Changing CCT. Please read this manual thoroughly before beginning installation or operation to ensure proper function and safety.
2. Safety Information
WARNING: To avoid electric shock, always turn off power at the main circuit breaker or fuse box before beginning installation or performing any maintenance. Ensure all electrical connections are made in accordance with local codes and ordinances.
- This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Proper grounding is required to ensure safety.
- Do not attempt to modify the fixture. Any modifications may void the warranty and create safety hazards.
- Consult a qualified electrician if you are unsure about any part of the installation process.
3. Package Contents
Verify that all components are present before beginning installation:
- 1 x LED Flushmount Fixture
- 1 x Mounting Hardware Kit (screws, wire nuts, etc.)
- 1 x Instruction Manual (this document)
4. Specifications
| Feature | Detail |
|---|---|
| Brand | Commercial Electric |
| Model Number | 017801742138 |
| Fixture Type | Round Flat Panel Ceiling Flushmount |
| Diameter | 15 inches |
| Wattage | 22.5 Watts |
| Brightness | 1650 Lumens |
| Color Temperature (CCT) | 3000K (Soft White), 4000K (Bright White), 5000K (Daylight) |
| Dimmable | Yes |
| Voltage | 120 Volts |
| Estimated Life | 50,000 hours / 45.7 years (based on 3 hours/day) |
| Mounting Type | Ceiling Flush Mount or Wall Sconce |
| Item Weight | 4.05 lbs |
| Dimensions | 16.5 x 16 x 2.5 inches (Package) |
| Energy Star Certified | Yes |
5. Setup & Installation
This fixture is designed for easy installation. Follow these steps carefully:
- Turn Off Power: Before starting, ensure the power to the installation area is turned off at the circuit breaker.
- Prepare Mounting Surface: Ensure the ceiling or wall surface is clean, dry, and structurally sound to support the fixture.
- Install Mounting Bracket: Attach the provided slide and lock mounting bracket to the electrical junction box using the hardware supplied. Ensure it is securely fastened.
- Make Electrical Connections:
- Connect the black wire from the fixture to the black (live) wire from the junction box.
- Connect the white wire from the fixture to the white (neutral) wire from the junction box.
- Connect the bare copper or green ground wire from the fixture to the ground wire from the junction box.
- Secure all connections with the provided wire nuts.
- Attach Fixture: Carefully align the fixture with the mounting bracket and slide it into place until it locks securely.
- Restore Power: Once the fixture is securely installed and all connections are made, restore power at the circuit breaker.

6. Operating Instructions
Power On/Off
Turn the light fixture on or off using a standard wall switch connected to the fixture.
Color Changing CCT (Correlated Color Temperature)
This fixture features selectable color temperature settings. You can choose between 3000K (Soft White), 4000K (Bright White), and 5000K (Daylight).
- Using the Selectable Color Switch: Some models may include a physical switch on the fixture itself to select the desired CCT before installation or during maintenance. Refer to the fixture for its specific location.
- Using a Standard Light Switch: If your fixture is set to "switch" mode, you can toggle between the color temperatures by simply flipping your standard wall light switch off and then quickly back on. The fixture will cycle through the available CCTs with each toggle.
Dimming Function
The fixture is dimmable. To utilize this feature, ensure you are using a compatible LED dimmer switch. Follow the dimmer switch manufacturer's instructions for installation and operation.
7. Maintenance
The integrated LED design of this fixture requires minimal maintenance.
- Cleaning: To clean the fixture, ensure the power is off. Wipe the exterior with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners or solvents, as they may damage the finish or electrical components.
- LEDs: The LEDs are integrated and cannot be replaced. The fixture has a long operational life, eliminating the need for bulb changes.
8. Troubleshooting
If you experience issues with your fixture, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power to the fixture; loose wiring connection; faulty wall switch. | Check circuit breaker and wall switch. Verify all wire connections are secure. Ensure power is off before checking connections. |
| Light flickers or dims unexpectedly. | Incompatible dimmer switch; loose wiring connection; voltage fluctuations. | Ensure a compatible LED dimmer switch is used. Check wiring connections. Consult an electrician if voltage issues are suspected. |
| Color temperature does not change. | Incorrect CCT setting; rapid switch toggling not detected. | If using the wall switch to change CCT, ensure you are toggling the switch off and on quickly. If there's a physical switch on the fixture, verify its setting. |
If these solutions do not resolve the issue, contact customer support.
9. Warranty Information
This Commercial Electric product is backed by a manufacturer's warranty. For specific warranty terms, duration, and claim procedures, please refer to the warranty card included with your purchase or visit the official Commercial Electric website. Keep your proof of purchase for warranty claims.
10. Customer Support
For technical assistance, replacement parts, or any questions regarding your Commercial Electric LED Flushmount Fixture, please contact Commercial Electric customer support. Contact information can typically be found on the product packaging or the manufacturer's official website.