1. Introduction

This manual provides essential information for the safe and efficient operation of your IBO 750W Submersible Sewage Pump. Please read these instructions carefully before installation, operation, or maintenance. Keep this manual for future reference.

The IBO 750W pump is designed for pumping dirty and clean water, including wastewater containing solids. Its integrated grinder system effectively shreds fibrous materials and solids, making it suitable for draining septic tanks, flooded rooms, and emptying swimming pools. The robust cast iron casing ensures durability for industrial-grade applications.

2. Safety Information

  • Electrical Safety: Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance. Ensure the power supply matches the pump's specifications (230V). Do not operate the pump with damaged cables or plugs.
  • Submersion: This pump is designed for submersible use only. Ensure it is fully submerged during operation to prevent overheating.
  • Water Type: The pump is suitable for dirty water, wastewater, and clean water. Avoid pumping flammable, corrosive, or explosive liquids.
  • Children and Pets: Keep children and pets away from the pump and the area of operation.
  • Stable Placement: Ensure the pump is placed on a stable, level surface to prevent tipping.
  • Personal Protective Equipment: Wear appropriate personal protective equipment (e.g., gloves, safety glasses) when handling the pump, especially when dealing with wastewater.

3. Product Overview

The IBO 750W Submersible Sewage Pump features a powerful motor, an integrated grinder, and an automatic float switch for reliable operation. Its robust construction is designed for demanding applications.

IBO 750W Submersible Sewage Pump with Float Switch

Figure 1: IBO 750W Submersible Sewage Pump. This image shows the main pump unit, including the motor housing, discharge outlet, and the attached float switch for automatic operation.

Storz C Coupling for Pump Hose

Figure 2: Storz C Coupling. This image displays the quick-connect Storz C coupling, used for securely attaching the discharge hose to the pump's outlet.

Components:

  • Pump Body: Durable cast iron construction.
  • Motor: 750W (0.75 kW) for powerful operation.
  • Grinder: Integrated system for shredding solids.
  • Float Switch: Automatic on/off control based on water level.
  • Discharge Outlet: Compatible with 2", 1 1/2", and 1" hose connections.
  • Power Cable: For electrical connection.

4. Setup

  1. Unpacking: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
  2. Hose Connection:
    • Attach the provided Storz C coupling to the pump's discharge outlet. Ensure a secure fit.
    • Connect the 20m hose (or your preferred hose) to the Storz C coupling. The pump also includes adaptors for 1 1/2" and 1" hoses if needed.
    • Route the discharge hose to the desired drainage point, ensuring it is free of kinks and obstructions.
  3. Positioning the Pump:
    • Place the pump on a firm, level surface in the water to be drained. Ensure the intake is clear of debris.
    • The pump must be fully submerged during operation.
  4. Float Switch Adjustment:
    • The float switch controls the automatic on/off function. Adjust the cable length of the float switch to set the desired water levels for activation and deactivation.
    • Ensure the float switch can move freely and is not obstructed by walls or other objects.
  5. Electrical Connection:
    • Connect the pump's power plug to a grounded 230V electrical outlet.
    • Ensure the outlet is protected by a residual current device (RCD) for safety.

5. Operating Instructions

  1. Initial Check: Before starting, ensure all connections are secure and the pump is correctly positioned.
  2. Starting the Pump:
    • Once the pump is submerged and the power is connected, the float switch will activate the pump automatically when the water level rises to the preset 'on' level.
    • The pump will continue to operate until the water level drops to the preset 'off' level, at which point the float switch will deactivate it.
  3. Manual Operation (if applicable): If your model allows for manual override, ensure the float switch is secured in an 'on' position, but monitor the pump closely to prevent dry running.
  4. Monitoring: Periodically check the pump's operation, discharge flow, and the area for any unusual noises or vibrations.
  5. Stopping the Pump: The pump will stop automatically when the water level drops. To manually stop the pump, disconnect it from the power supply.

6. Maintenance

Regular maintenance ensures the longevity and efficient performance of your pump. Always disconnect the pump from the power supply before any maintenance.

  • Cleaning the Pump: After use, especially with dirty water, rinse the pump thoroughly with clean water. Remove any debris or foreign objects from the intake screen, impeller, and grinder area.
  • Checking Cables and Connections: Regularly inspect the power cable, plug, and hose connections for wear, damage, or leaks. Replace damaged components immediately.
  • Float Switch: Ensure the float switch is clean and moves freely. Debris can impede its operation.
  • Storage: When not in use for extended periods, clean the pump, drain any remaining water, and store it in a dry, frost-free location.

7. Troubleshooting

ProblemPossible CauseSolution
Pump does not start.No power supply.
Float switch not activated.
Motor overload/thermal protection activated.
Check power connection and circuit breaker.
Ensure water level is high enough to activate float switch.
Disconnect power, allow pump to cool, then restart.
Pump runs but no water is discharged or flow is low.Hose kinked or blocked.
Intake screen blocked.
Impeller/grinder blocked.
Check and clear hose.
Disconnect power, clean intake screen.
Disconnect power, carefully clear impeller/grinder area.
Pump stops unexpectedly.Water level too low (float switch deactivated).
Thermal overload.
Power interruption.
Check water level and float switch position.
Allow pump to cool down.
Check power supply.
Unusual noise or vibration.Debris in impeller/grinder.
Pump not stable.
Disconnect power, clear debris.
Ensure pump is on a stable, level surface.

8. Specifications

ModelIBO 750W Submersible Sewage Pump
Power Supply230 V / 3.8 A
Motor Power0.75 kW (750 W)
Max. Flow Rate300 l/min (15,000 l/hour)
Max. Discharge Head12 m
Connection Size2" (with adaptors for 1 1/2", 1")
WeightApprox. 20 kg
Dimensions (Diameter x Height)26 cm x 47 cm
MaterialCast Iron
Included Hose Length20 m

9. Warranty and Support

For warranty information and technical support, please refer to your purchase documentation or contact the seller directly. Keep your proof of purchase for any warranty claims.

IBO is committed to providing quality products. If you encounter any issues not covered in this manual, please seek professional assistance or contact the authorized service center.

Related Documents - 750W

PreviewIBO ISQ Series Submersible Pumps User Manual
Comprehensive user manual for IBO ISQ series submersible pumps, covering installation, operation, maintenance, safety precautions, and troubleshooting for efficient water pumping applications.
PreviewNávod k použití: IBO AUTO IBO Povrchová čerpadla a Hydrofory
Kompletní návod k použití pro povrchová čerpadla a hydrofory IBO AUTO IBO. Obsahuje informace o instalaci, provozu, údržbě, řešení problémů a technické specifikace.
PreviewIBO PN-1000 Pneumatic Level Controller User Manual
User manual for the IBO PN-1000 pneumatic level controller, detailing installation, operation, safety precautions, maintenance, disposal, and warranty information. This device automatically controls submersible pumps based on liquid levels.
PreviewIBO SOLAR Pressure Vessels - Instruction Manual
Comprehensive instruction manual for IBO SOLAR diaphragm pressure vessels, covering installation, operation, maintenance, technical specifications, and safety guidelines for solar and hot water systems.
PreviewInstrukcja obsługi pompy zatapialnej IBO DRAIN 400
Szczegółowa instrukcja obsługi dla pompy zatapialnej IBO DRAIN 400. Zawiera informacje o instalacji, bezpiecznym użytkowaniu, konserwacji i rozwiązywaniu problemów.
PreviewIBO IVR 10: Instrukcja obsługi sterownika pomp
Instrukcja obsługi dla inteligentnego sterownika pomp IBO IVR 10. Przewodnik zawiera szczegółowe informacje dotyczące instalacji, bezpiecznego użytkowania, danych technicznych, diagnostyki błędów i konserwacji, przeznaczony do zastosowań przemysłowych.