Innova 2.0 INNOVA
Innova 2.0 INNOVA Monobloc Air Conditioner User Manual
Model: 2.0 INNOVA
1. Introduction
This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Innova 2.0 INNOVA Monobloc Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.
2. Safety Information
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury.
- Ensure the power supply voltage matches the rating label on the unit.
- Do not operate the unit with wet hands or when standing on a wet surface.
- Do not insert objects into the air outlet or inlet.
- Keep the unit away from flammable materials and heat sources.
- Disconnect power before cleaning or performing any maintenance.
- Installation must be performed by qualified personnel in accordance with local electrical codes.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Product Overview
The Innova 2.0 INNOVA Monobloc Air Conditioner is a versatile unit designed for both cooling and heating, featuring an inverter heat pump technology for efficient climate control. Its minimal design allows for flexible installation options.
Key Features:
- Type: Inverter Heat Pump
- Style: Minimal
- Installation: Floor or Wall Mounted
- Material: Metal
- Special Feature: Inverter Compressor
- Cooling Power: 9000 BTU

Figure 3.1: Front view of the Innova 2.0 INNOVA Monobloc Air Conditioner, showcasing its minimalist design and white matte finish.
4. Setup and Installation
The Innova 2.0 INNOVA Monobloc Air Conditioner can be installed either on the floor or mounted on a wall. Professional installation is recommended to ensure proper functioning and safety.
Wall Installation Overview:
- Unit Placement (A): Determine the optimal position for the main unit on the wall, ensuring adequate clearance around the unit for airflow and maintenance.
- Wall Openings: Create necessary openings in the wall for air ducts. These openings will accommodate the plastic protection sleeves and internal flanges.
- Protection Sleeves and Flanges (B): Insert the plastic protection sleeves and internal flanges into the wall openings. These components ensure proper sealing and insulation.
- Outdoor Grills (C): Install the outdoor self-foldable grills on the exterior side of the wall openings. These grills protect the ducts from external elements.
- Secure Unit: Mount and secure the main unit to the wall, connecting it to the internal ducting.
- Electrical Connection: Connect the unit to the electrical power supply as per local regulations.

Figure 4.1: Diagram illustrating the key components and steps for wall installation, including the main unit (A), internal protection sleeves and flanges (B), and outdoor self-foldable grills (C).
Floor Installation:
For floor installation, ensure the unit is placed on a stable, level surface. Follow the manufacturer's specific guidelines for ducting and electrical connections, which may vary based on the chosen floor-standing configuration.
5. Operating Instructions
Your Innova 2.0 INNOVA Monobloc Air Conditioner is designed for user-friendly operation. Specific controls (e.g., remote control, integrated panel) will be detailed in the separate quick start guide provided with your unit. Generally, the unit offers various modes:
- Cooling Mode: For reducing room temperature.
- Heating Mode: For increasing room temperature (heat pump function).
- Fan Mode: Circulates air without cooling or heating.
- Dehumidification Mode: Reduces humidity in the air.
- Automatic Mode: The unit automatically selects the appropriate mode based on the ambient temperature.
Refer to the quick start guide for detailed instructions on setting temperature, fan speed, and timer functions.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always disconnect the power supply before performing any maintenance.
Cleaning the Air Filter:
- The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Open the front panel of the unit to access the air filter.
- Remove the filter and clean it with a vacuum cleaner or wash it with lukewarm water and a mild detergent.
- Allow the filter to dry completely before reinstalling it.
Exterior Cleaning:
Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners, waxes, or polishes, as these can damage the surface.
7. Troubleshooting
Before contacting customer service, please refer to the following common issues and their potential solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; power cord not properly connected; circuit breaker tripped. | Check power connection; reset circuit breaker; ensure power outlet is functional. |
| Insufficient cooling/heating | Dirty air filter; blocked air inlets/outlets; room too large for unit capacity; doors/windows open. | Clean air filter; clear obstructions; ensure proper room size; close doors/windows. |
| Unusual noise | Loose parts; unit not level; foreign object inside. | Check for loose components; ensure unit is on a level surface; contact service if noise persists. |
| Water leakage | Drainage hose blocked or improperly installed. | Check and clear drainage hose; ensure proper installation and slope. |
If the problem persists after attempting these solutions, please contact a qualified service technician.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Innova |
| Model Name | Climatiseur monobloc sans unite d'externe 2.0 INNOVA |
| Type | Inverter Heat Pump |
| Installation Method | On the floor or on the wall |
| Cooling Power | 9000 BTU (British Thermal Unit) |
| Special Feature | Inverter Compressor |
| Voltage | 2.3E+2 Volts (alternating current) |
| Power Source | Electric Cable |
| Color | White Matte |
| Package Dimensions | 1.19 x 0.79 x 0.61 cm; 50 kilograms |
| Energy Efficiency Rating (BEE) | 5 Star |
| Seasonal Energy Efficiency Ratio (SEER) | 20 |
9. Warranty and Support
For information regarding the product warranty, please refer to the warranty card included with your purchase or contact your retailer. For technical support or service inquiries, please reach out to Innova customer service or an authorized service center.
Spare Parts Availability: Information regarding spare parts availability is currently unavailable. Please contact the manufacturer or your retailer for details.
Ask a question about this manual