1. Introduction
This manual provides essential information for the safe and efficient operation of your Xmart by Integra SAI-SUPRA-901 Uninterruptible Power Supply (UPS). This interactive UPS system features an internal voltage regulator to extend the operational input range and minimize battery usage. It offers comprehensive protection against various electrical grid issues, ensuring stable power for your connected devices. The unit is available in 120 VAC, 220 V, and 230 V versions.
2. Safety Information
Please read all safety instructions carefully before installing, operating, or servicing the UPS. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Do not open the UPS casing. There are no user-serviceable parts inside. Refer all servicing to qualified service personnel.
- Do not install the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Ensure the UPS is connected to a grounded power outlet.
- Do not connect non-computer related equipment (e.g., medical equipment, life support systems) to the UPS.
- Disconnect the UPS from the power outlet before cleaning. Use a dry cloth only.
- Battery replacement should only be performed by qualified personnel using the same type and number of batteries.
3. Package Contents
Verify that all items are present in the package:
- Xmart by Integra SAI-SUPRA-901 UPS Unit
- Power Cable
- User Manual (this document)
4. Product Overview
The Xmart by Integra SAI-SUPRA-901 is a compact, black, rectangular Uninterruptible Power Supply designed to protect your electronic devices from power fluctuations and outages.

Image Description: A black, rectangular Uninterruptible Power Supply (UPS) unit. The front panel features a green LED indicator light on the left and a circular power button on the right. The Xmart by Integra logo is prominently displayed at the bottom front of the unit. The top and side panels feature ventilation grilles.
Front Panel Indicators and Controls:
- Power Button: Used to turn the UPS on or off.
- LED Indicator: Displays the operational status of the UPS (e.g., green for normal operation).
5. Setup
Follow these steps to set up your UPS:
- Placement: Place the UPS on a flat, stable surface in a well-ventilated area, away from direct sunlight, heat, and moisture.
- Connect to Wall Outlet: Plug the UPS power cable into a grounded wall outlet.
- Initial Charging: Allow the UPS to charge for at least 8 hours before connecting any devices to ensure optimal battery performance.
- Connect Devices: Plug your computer and other critical electronic devices into the output receptacles on the rear of the UPS. Ensure the total load does not exceed the UPS's capacity.
- RJ11 Protection (Optional): If desired, connect your telephone line or network cable through the RJ11 ports on the UPS for surge protection.
6. Operating Instructions
Turning On/Off:
- To Turn On: Press and hold the power button on the front panel for approximately 2 seconds until the LED indicator illuminates.
- To Turn Off: Press and hold the power button again for approximately 2 seconds until the LED indicator turns off.
Key Features:
- Integrated Voltage Regulation: Automatically corrects minor voltage fluctuations without switching to battery power, preserving battery life.
- Microprocessor Control: Ensures precise and reliable operation of the UPS.
- Total Electrical Protection: Guards against surges, spikes, sags, and power outages.
- RJ11 Protection: Provides surge protection for connected telephone or network lines.
- Battery Support: Supplies backup power during outages, allowing for safe shutdown of connected equipment.
7. Maintenance
Proper maintenance ensures the longevity and optimal performance of your UPS.
- Battery Care: The UPS uses a sealed lead-acid battery. To maximize battery life, avoid storing the UPS in high temperatures and ensure it is fully charged before initial use. If the UPS is stored for an extended period, recharge it every three months.
- Cleaning: Disconnect the UPS from the power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners.
- Ventilation: Ensure that the ventilation openings on the UPS are not blocked to prevent overheating.
8. Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS does not turn on. | No input power; Low battery; UPS fault. | Check power cable connection; Allow UPS to charge; Contact support if issue persists. |
| UPS beeps continuously. | Overload; Low battery. | Reduce connected load; Allow UPS to charge. |
| Connected devices lose power during an outage. | Battery depleted; UPS fault. | Ensure UPS is fully charged; Contact support. |
| UPS does not provide expected backup time. | Overload; Aging battery. | Reduce connected load; Consider battery replacement. |
9. Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Xmart by Integra |
| Item Model Number | SAI-SUPRA-901 |
| Color | Black |
| Product Type | Rectangular form |
| Compatible Devices | PC |
| Battery Composition | Sealed lead-acid |
| Battery Requirements | 1 x 12V battery required |
| Voltage | 230 Volts |
| Item Weight | 3.6 Kilograms |
| Form Factor | Rectangular |
| Power Plug Type | Type F – 2 pins (Germany and Spain) |
| Output Power | 1000 Watts |
| Power | 1000 Watts |
| Manufacturer | Integra |
10. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for warranty claims.