1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Mirage Life+ 12,000 BTU Mini-Split Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference. Proper use and maintenance will ensure optimal performance and extend the lifespan of your unit.

Figure 1: Mirage Life+ Mini-Split Air Conditioner. This image displays both the indoor unit (evaporator) and the outdoor unit (condenser) of the Mirage Life+ mini-split air conditioner. The indoor unit is a sleek white rectangular panel, typically mounted on a wall, with the Mirage logo visible. The outdoor unit is a larger, squarish white box with a circular fan grille, also featuring the Mirage Life+ logo and 'LIFE 12+' branding.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Electrical Safety: Ensure the unit is connected to a properly grounded 220V electrical outlet. Do not use extension cords.
- Installation: Installation must be performed by qualified personnel in accordance with local electrical and building codes.
- Maintenance: Disconnect power before performing any maintenance or cleaning.
- Refrigerant: This unit uses R410a refrigerant. Handling of refrigerant should only be done by certified technicians.
- Children and Pets: Keep children and pets away from the outdoor unit and ensure they do not play with the remote control.
- Obstructions: Do not block the air intake or outlet vents of either unit.
3. Package Contents
Verify that all components are present and undamaged upon unpacking:
- Indoor Unit (Evaporator)
- Outdoor Unit (Condenser)
- Remote Control with Batteries
- Installation Plate for Indoor Unit
- Drain Hose
- Refrigerant Piping (pre-charged or separate, depending on model)
- User Manual (this document)
- Warranty Card
4. Setup and Installation
Installation of this mini-split air conditioner requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician to ensure proper function, safety, and warranty validity.
4.1. Site Selection
- Indoor Unit: Choose a location that allows for even air distribution, away from direct sunlight or heat sources, and with sufficient space for maintenance.
- Outdoor Unit: Select a well-ventilated area, free from obstructions, and on a stable, level surface. Ensure adequate clearance around the unit for airflow and service access.
4.2. Installation Steps (Overview for Technician)
- Mount the indoor unit's installation plate.
- Drill a hole through the wall for refrigerant piping and drain hose.
- Install the outdoor unit on a stable base.
- Connect refrigerant pipes between indoor and outdoor units.
- Connect the drain hose.
- Perform vacuuming and check for leaks.
- Connect electrical wiring (220V).
- Mount the indoor unit onto the plate.
- Test the unit's operation.
5. Operating Instructions
Your Mirage Life+ mini-split unit offers various operating modes for optimal comfort. Use the remote control to select functions.
5.1. Remote Control Functions
The remote control allows you to power on/off the unit, select operating modes, adjust temperature, fan speed, and set timers.
5.2. Operating Modes
- Cool Mode (Cool): Sets the unit to cool the room. Adjust the temperature to your desired level.
- Heat Mode (Heat): Sets the unit to heat the room. Adjust the temperature to your desired level.
- Fan Mode: Circulates air without cooling or heating. Fan speed can be adjusted.
- Dry Mode (Dehumidification): Reduces humidity in the room.
- Auto Mode: The unit automatically selects the appropriate mode (Cool, Heat, or Fan) based on the room temperature and your set temperature.
5.3. Temperature and Fan Speed Adjustment
- Use the TEMP UP/DOWN buttons on the remote to set the desired temperature.
- Use the FAN SPEED button to cycle through low, medium, high, or auto fan speeds.
6. Maintenance
Regular maintenance ensures efficient operation and prolongs the life of your air conditioner. Always disconnect power before performing any maintenance.
6.1. Air Filter Cleaning (Monthly)
- Open the front panel of the indoor unit.
- Remove the air filters.
- Clean the filters with a vacuum cleaner or wash them with lukewarm water and mild detergent.
- Allow filters to dry completely before reinstalling.
- Close the front panel.
6.2. Outdoor Unit Cleaning (Annually)
Periodically clear any debris (leaves, dirt) from around the outdoor unit. The condenser coils may require professional cleaning to maintain efficiency.
6.3. Professional Service (Annually)
It is recommended to have a qualified technician inspect and service your unit annually to check refrigerant levels, clean coils, and ensure all components are functioning correctly.
7. Troubleshooting
Before contacting service, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power, remote control batteries dead, circuit breaker tripped. | Check power supply, replace remote batteries, reset circuit breaker. |
| Insufficient cooling/heating | Dirty air filters, blocked outdoor unit, wrong mode selected, low refrigerant. | Clean filters, clear obstructions, select correct mode, contact technician for refrigerant check. |
| Unusual noise | Loose parts, fan obstruction, compressor issue. | Check for loose parts, clear obstructions. If noise persists, contact technician. |
| Water leakage from indoor unit | Clogged drain hose, improper installation. | Clear drain hose. If issue persists, contact technician. |
If the problem persists after attempting these solutions, please contact a qualified service technician.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Mirage |
| Model Name | Life+ Frio y Calor |
| Cooling Capacity | 12,000 British Thermal Units (1 Ton) |
| Voltage | 220 Volts |
| Refrigerant Type | R410a |
| Special Feature | Heating and Cooling Function |
| Noise Level | 41 dB |
| Indoor Unit Dimensions (WxDxH) | 80.5 cm x 19.4 cm x 28.5 cm (approx.) |
| Outdoor Unit Dimensions (WxDxH) | 85.85 cm x 38 cm x 79.98 cm (approx.) |
| Weight | 41 kg (total package approx.) |
| Power Source | Corded Electric |
9. Warranty and Support
Your Mirage Life+ Mini-Split Air Conditioner is covered by a manufacturer's warranty. Please refer to the warranty card included in your package for specific terms, conditions, and duration. For technical support, service requests, or warranty claims, please contact Mirage customer service or your authorized dealer. Keep your purchase receipt as proof of purchase.
For additional information, you may visit the official Mirage website or contact their support channels.