OWON B41T+

OWON B41T+ Digital Multimeter User Manual

Model: B41T+

1. Introduction

This manual provides comprehensive instructions for the safe and effective operation, setup, and maintenance of the OWON B41T+ Digital Multimeter. The B41T+ is a versatile 3-in-1 device, functioning as a datalogger, a multimeter, and a temperature meter. It incorporates True RMS measurement capabilities and a clear backlight for enhanced readability in various environments.

2. Safety Information

To ensure safe operation and prevent personal injury or damage to the device, please observe the following safety precautions:

3. Package Contents

Upon opening the package, verify that all the following items are included:

OWON B41T+ Multimeter with included accessories and carry bag
Figure 3.1: OWON B41T+ Multimeter with its complete set of accessories and carry bag.

4. Product Overview

The OWON B41T+ Digital Multimeter features a robust design with a clear digital display, a central rotary function dial, and various input terminals for different measurement types.

Front view of the OWON B41T+ Digital Multimeter showing the display, function dial, and buttons
Figure 4.1: Front view of the OWON B41T+ Digital Multimeter, highlighting the display, function dial, and control buttons.

4.1. Key Components

Close-up view of the input jacks on the OWON B41T+ Multimeter
Figure 4.2: Close-up of the input jacks, indicating their respective maximum ratings and functions.
Angled view of the OWON B41T+ Multimeter with its kickstand extended
Figure 4.3: Angled view of the OWON B41T+ Multimeter, showing the integrated kickstand for convenient viewing.
Rear view of the OWON B41T+ Multimeter, showing the battery compartment and caution label
Figure 4.4: Rear view of the OWON B41T+ Multimeter, displaying the battery compartment cover and safety warnings.

5. Setup

5.1. Battery Installation

The OWON B41T+ requires two 1.5V AA batteries for operation. Batteries are typically included with the device.

  1. Ensure the multimeter is powered OFF.
  2. Locate the battery compartment on the rear of the device.
  3. Use a screwdriver to open the battery compartment cover.
  4. Insert two AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Replace the battery compartment cover and secure it with the screw.

5.2. Connecting Test Leads

Proper connection of test leads is crucial for accurate and safe measurements.

6. Operating Instructions

6.1. Basic Measurement Procedure

  1. Connect the test leads as described in Section 5.2.
  2. Turn the function dial to the desired measurement mode.
  3. Connect the test probes to the circuit or component under test.
  4. Read the measurement value on the display.

6.2. Function Selection

Use the rotary dial to select the primary measurement function:

6.3. Button Functions

6.4. Data Logging and Bluetooth Connectivity

The OWON B41T+ features Bluetooth connectivity, allowing it to interface with a mobile application for advanced data logging and analysis.

Refer to the specific mobile application's instructions for detailed guidance on pairing and using these advanced features.

7. Maintenance

7.1. Cleaning

To maintain the device's performance and appearance:

7.2. Battery Replacement

When the low-battery indicator appears on the display, replace the batteries promptly to ensure accurate readings.

  1. Power off the multimeter and disconnect all test leads.
  2. Open the battery compartment cover on the rear of the device (refer to Section 5.1).
  3. Remove the old AA batteries.
  4. Insert new 1.5V AA batteries, ensuring correct polarity.
  5. Securely close the battery compartment cover.

7.3. Fuse Replacement

If the current measurement functions cease to work, the internal fuse may need replacement. Refer to the device's internal markings or the full technical manual for specific fuse ratings and replacement procedures. Always use a fuse with the correct voltage and current rating.

7.4. Storage

For long-term storage, remove the batteries to prevent leakage and store the multimeter in its carry bag in a cool, dry place, away from direct sunlight and extreme temperatures.

OWON B41T+ Multimeter stored inside its protective carry bag
Figure 7.1: The OWON B41T+ Multimeter neatly stored within its protective carry bag.

8. Troubleshooting

This section addresses common issues you might encounter with your OWON B41T+ Multimeter.

9. Specifications

FeatureSpecification
BrandOWON
ModelB41T+
Display21999 Counts, 4(1/2)-digit
True RMSYes
Auto-scaleYes
Max / Min ValueYes
Offline Recording FunctionYes
Record Period168 hours (7 days)
Record Length10,000 points
LCD BacklightYes
Diode TestYes
Continuity Test (Audion Test)Yes
Data HoldYes
Input ProtectionYes
Auto TestYes
Low-battery IndicatorYes
Input Impedance10MΩ
Relative MeasurementYes
Frequency Response(40 - 10000) Hz
Shift Rate3 times/s
Simulate Chart Shift Rate30 times/s
Battery3V (1.5V x 2) AA
Dimensions (WxHxD)85mm x 185mm x 30mm (approx. 3.35 x 7.28 x 1.18 inches)
Device Weight0.32 kg (approx. 11.3 ounces)
ColorBlack, Blue
Power SourceBattery Powered
Measurement TypeMultimeter
Min. Operating Voltage3 Volts
UPC884473045276, 695087763636

10. Warranty and Support

For detailed warranty information, technical support, or service inquiries regarding your OWON B41T+ Digital Multimeter, please refer to the official OWON website or contact their customer service department. Keep your purchase receipt as proof of purchase for warranty claims.

Related Documents - B41T+

Preview OWON HDS100 Series Oscilloscope Meter: User Manual and Quick Start Guide
Comprehensive user manual and quick start guide for the OWON HDS100 Series Oscilloscope Meter, covering safety, operation, instrument features, system settings, and maintenance for efficient and safe use.
Preview OWON HDS100 Series Oscilloscope Meter User Manual | Safety, Operation, and Specifications
Comprehensive user manual for the OWON HDS100 Series Oscilloscope Meter, covering safety information, quick start guide, multimeter and oscilloscope operation, technical specifications, and maintenance. Learn how to use your OWON device effectively and safely.
Preview Multimeter SCPI Protocol Guide
Explore the Standard Commands for Programmable Instruments (SCPI) protocol for OWON multimeters. This guide details command syntax, rules, and common commands for programming test equipment.
Preview OWON SPM-Serie Source-Meter Benutzerhandbuch
Umfassendes Benutzerhandbuch für das OWON SPM-Serie Source-Meter. Enthält detaillierte Anleitungen zur Bedienung, Sicherheitshinweise, Schnellstart, Fehlerbehebung und Wartung.
Preview Owon FDS Series Digital Oscilloscope Technical Specifications
Detailed technical specifications for the Owon FDS Series digital oscilloscopes, including FDS1102 and FDS1102A models, covering performance characteristics, trigger functions, waveform generation, power supply, and multimeter capabilities.
Preview OWON CMS101 Digital Oscilloscope & Multimeter Clamp Meter User Manual
Comprehensive user manual for the OWON CMS101 Digital Oscilloscope & Multimeter Clamp Meter, covering safety information, quick start guide, instrument panel details, multimeter and oscilloscope usage, technical specifications, and maintenance.