Lenz CP-752-10

Lenz CP-752-10 Hydraulic Filter Canister User Manual

Model: CP-752-10 | Brand: Lenz

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Lenz CP-752-10 Hydraulic Filter Canister. Designed for superior system protection, this 10-micron filter is engineered for demanding industrial hydraulic applications. Please read this manual thoroughly before installation and use to ensure optimal performance and longevity of your hydraulic system components.

2. Safety Information

3. Product Overview

The Lenz CP-752-10 is a spin-on hydraulic filter canister designed for return line applications. It features a 10-micron filtration rating, ensuring the removal of fine particulates from hydraulic fluids. Its robust aluminum die-cast body and Buna-N seals provide durability and compatibility with various fluid types.

Lenz CP-752-10 Hydraulic Filter Canister

Figure 3.1: Front view of the Lenz CP-752-10 Hydraulic Filter Canister, showing the brand name and model number.

Side view of Lenz CP-752-10 Hydraulic Filter Canister with installation instructions

Figure 3.2: Side view of the filter canister, illustrating typical installation and maintenance symbols.

4. Installation (Setup)

Follow these steps for proper installation of the Lenz CP-752-10 Hydraulic Filter Canister:

  1. Prepare the System: Ensure the hydraulic system is shut down and completely depressurized. Isolate the filter housing from the system.
  2. Remove Old Filter: Carefully unscrew and remove the old filter canister. Be prepared for residual fluid drainage and contain it properly.
  3. Clean Mounting Surface: Clean the filter mounting base thoroughly, removing any debris or old gasket material.
  4. Lubricate Gasket: Apply a thin film of clean hydraulic fluid to the new filter's gasket (Buna-N seal).
  5. Install New Filter: Screw the new Lenz CP-752-10 filter onto the mounting base until the gasket makes contact. Then, tighten an additional 1/2 to 3/4 turn by hand. Do not overtighten.
  6. Check for Leaks: Re-pressurize the system slowly and check for any leaks around the filter seal. Address any leaks immediately.
  7. Bleed Air: If necessary, bleed air from the system according to the hydraulic system manufacturer's instructions.
Top view of Lenz CP-752-10 Hydraulic Filter Canister showing threaded opening and gasket

Figure 4.1: Top view of the filter, highlighting the threaded opening and gasket for proper installation.

5. Operation

Once installed, the Lenz CP-752-10 filter operates continuously to remove contaminants from the hydraulic fluid. It is designed to maintain an optimal flow rate of 20 GPM while effectively filtering particulates down to 10 microns. Regular monitoring of system pressure and fluid condition is recommended to ensure the filter is functioning correctly and to identify when replacement is necessary.

Video 5.1: An overview of a hydraulic oil filter element, demonstrating its appearance and packaging. This video provides a visual reference for the type of product being discussed.

6. Maintenance

Regular maintenance is crucial for the performance and lifespan of your hydraulic system. The Lenz CP-752-10 is a spin-on, replaceable cartridge filter.

Filter Replacement:

The filter element should be replaced at intervals recommended by your hydraulic system manufacturer or when a significant pressure drop across the filter indicates clogging. Refer to Section 4 for detailed replacement steps.

7. Troubleshooting

ProblemPossible CauseSolution
Fluid Leakage around FilterImproperly tightened filter, damaged gasket, incorrect filter size.Ensure filter is hand-tightened correctly (1/2 to 3/4 turn past contact). Inspect and replace gasket if damaged. Verify correct filter model.
Reduced System Flow/PressureClogged filter element.Replace the filter element. Check for other system blockages if problem persists.
Excessive System NoiseSeverely clogged filter causing cavitation.Immediately replace the filter element. Inspect pump for damage.

8. Specifications

FeatureSpecification
Model NumberCP-752-10
Filtration Rating10 Micron
Flow Rate (Max)20 GPM
Maximum Pressure200 PSI
Temperature Range-22°F to +212°F (-30°C to +100°C)
Thread Type1"-12 UNF
Construction MaterialAluminum Die-Cast Body
Seal MaterialBuna-N
WeightApproximately 1 lb (16 ounces)
DimensionsApproximately 6 x 6 x 6 inches

9. Warranty and Support

For specific warranty information, please refer to the documentation provided with your purchase or contact Lenz directly. For technical support or inquiries regarding the CP-752-10 Hydraulic Filter Canister, please visit the official Lenz website or contact their customer service department.

Lenz Contact Information:

Related Documents - CP-752-10

Preview Lenz Android Bus Validator E60: Instruction Manual | Features, Installation, Operation
This instruction manual provides detailed information on the Lenz Android Bus Validator E60, a smart POS terminal designed for public transportation. It covers product features, installation procedures, basic operations, troubleshooting, and FCC compliance. Learn about its advanced processor, multiple payment options including QR codes and contactless cards, and connectivity features.
Preview LENZ W1 EVSE User Manual & Installation Guide
Comprehensive user manual and installation guide for the LENZ W1 EVSE, a durable wall-mounted electric vehicle charging station designed for efficient EV charging, featuring adjustable amperage and robust construction.
Preview LENZ W1 EVSE User Manual & Installation Guide - Electric Vehicle Charger
Comprehensive user manual and installation guide for the LENZ W1 EVSE, a durable wall-mounted electric vehicle charging station. Learn about product specifications, safety instructions, step-by-step installation, status indicators, maintenance, and warranty information.
Preview LENZ Heated Apparel Safety and Care Instructions
Safety and care guidelines for LENZ heated apparel, detailing washing, drying, and usage with LENZ Lithium Packs to prevent electric shock, fire, and injury.
Preview Lenz lithium pack insole rcB 1200 User Manual
Comprehensive user manual for the Lenz lithium pack insole rcB 1200, detailing operation, safety, and maintenance. Learn how to use and care for your heated insoles.
Preview LZE500 Mobile DVR User Manual
User manual for the Xiamen Lenz Communication Co.,Ltd LZE500 Mobile DVR, providing detailed information on product features, specifications, installation procedures, wiring diagrams, and interface pin definitions.