1. Introduction
Thank you for choosing the IBO 25-60/180 OHI circulating pump. This manual provides important information regarding the safe installation, operation, and maintenance of your pump. Please read these instructions carefully before installation and use, and keep them for future reference. Proper installation and maintenance will ensure optimal performance and longevity of the product.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death.
- Electrical Safety: Always disconnect the pump from the power supply before performing any installation, maintenance, or repair work. Ensure that the electrical installation complies with local regulations and standards. The pump operates on 230 V- 50 Hz.
- Qualified Personnel: Installation and electrical connections should only be performed by qualified and authorized personnel.
- Fluid Temperature: The pump is designed for fluid temperatures between +5 °C and +110 °C. Handle hot fluids with extreme caution to prevent burns.
- Pressure: The nominal pressure is 10 bar. Ensure the system's pressure does not exceed this limit.
- Protection Rating: The pump has an IP 44 protection rating, meaning it is protected against solid objects larger than 1mm and against splashing water from any direction. However, it is not waterproof and should not be submerged.
- Intended Use: This pump is intended for circulating water in heating systems. Do not use it for other purposes without consulting the manufacturer.
3. Product Overview
The IBO 25-60/180 OHI is a robust circulating pump designed for efficient fluid circulation in various systems, primarily heating applications. It features a 3-speed motor, allowing users to adjust performance to specific system requirements. Constructed with high-quality materials, including a ceramic motor shaft, and an encapsulated motor, it ensures quiet and reliable operation.
Key Features:
- 3-speed motor for adjustable performance.
- Suitable for fluid temperatures from +5 °C to +110 °C.
- Maximum discharge head of 4 meters.
- Operates on 230 V- 50 Hz power supply.
- IP 44 protection rating.
- Equipped with a durable ceramic motor shaft.
- Encapsulated motor design for enhanced reliability.
- Nominal pressure of 10 bar.
- Quiet operation due to high-quality materials and construction.
Figure 1: IBO 25-60/180 OHI Circulating Pump, showing the pump unit, its packaging, and included seals.
4. Setup and Installation
4.1 Pre-Installation Checks
- Verify that the pump model matches your system requirements.
- Inspect the pump for any visible damage from shipping.
- Ensure all necessary tools and fittings are available.
- Confirm that the power supply (230 V- 50 Hz) is accessible and correctly rated.
4.2 Mounting the Pump
The pump should be installed in a horizontal position with the motor shaft horizontal to ensure proper lubrication and cooling. Ensure there is sufficient space around the pump for ventilation and future maintenance.
- Install the pump in the return line of the heating system, if possible, to operate at lower temperatures and extend its lifespan.
- Use appropriate shut-off valves on both sides of the pump to allow for isolation during maintenance without draining the entire system.
- Ensure the pipework is adequately supported to prevent strain on the pump connections.
- Use the provided seals to ensure watertight connections.
Figure 2: Side view of the pump, illustrating the inlet and outlet connections for pipework integration.
4.3 Electrical Connection
- All electrical work must be carried out by a qualified electrician.
- Connect the pump to a dedicated electrical circuit protected by a fuse or circuit breaker.
- Ensure proper grounding (earthing) of the pump.
- Follow the wiring diagram provided on the pump's terminal box or in the full manufacturer's documentation.
4.4 System Filling and Priming
- After installation, slowly fill the heating system with water, ensuring all air is vented from the system.
- Open the bleed screw on the pump (if present) to release any trapped air within the pump housing.
- Once the system is full and air-free, close the bleed screw.
5. Operating Instructions
5.1 Initial Start-up
- Ensure the system is completely filled with water and all air has been removed.
- Turn on the power supply to the pump.
- The pump should start operating. Listen for any unusual noises, which may indicate trapped air or an obstruction.
5.2 Speed Selection
The IBO 25-60/180 OHI pump is equipped with a 3-speed selector switch, typically located on the motor housing. This allows you to adjust the pump's performance to match the specific requirements of your heating system.
- Speed I (Low): For systems requiring minimal circulation or during periods of low heat demand.
- Speed II (Medium): A balanced setting for general operation.
- Speed III (High): For systems requiring maximum circulation, such as during initial heat-up or in larger systems.
Select the speed that provides adequate heat distribution without causing excessive noise or energy consumption. You may need to experiment to find the optimal setting for your system.
6. Maintenance
The IBO 25-60/180 OHI circulating pump is designed for minimal maintenance. However, regular checks can help ensure its long-term reliability.
- Annual Inspection: Annually, check the pump for any signs of leaks, corrosion, or unusual noises.
- System Water Quality: Ensure the heating system water is clean and free of debris. Poor water quality can lead to blockages and premature wear.
- Bleeding: Periodically check and bleed the system and pump to remove any trapped air, which can cause noise and reduce efficiency.
- Cleaning: Keep the exterior of the pump clean and free from dust and dirt to ensure proper heat dissipation.
- Winterization: If the heating system is shut down for an extended period in freezing conditions, ensure the system (including the pump) is drained or protected with antifreeze to prevent damage from freezing.
7. Troubleshooting
Before attempting any troubleshooting, always disconnect the pump from the power supply.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start |
|
|
| Pump is noisy |
|
|
| Insufficient flow/heat |
|
|
| Leakage |
|
|
8. Specifications
Figure 3: Pump label displaying key technical specifications and power settings.
| Specification | Value |
|---|---|
| Model Number | 25-60/180 |
| Brand | IBO |
| Manufacturer | Dambat |
| Power Supply Voltage | 230 V- 50 Hz |
| Protection Rating | IP 44 |
| Fluid Temperature Range | +5 °C to +110 °C |
| Maximum Discharge Head | 4 meters |
| Nominal Pressure | 10 bar |
| Maximum Flow Rate | 55 Litres per minute |
| Material | Bronze |
| Product Dimensions (L x W x H) | 19 x 14 x 13 cm |
| Weight | 2.64 kilograms |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for warranty claims.