Flojet 04405143A

Flojet Quad DC Water System Pump User Manual

Model: 04405143A | Brand: Flojet

Product Overview

The Flojet Quad DC Water System Pump is a robust and efficient solution for various water transfer applications. Designed for reliability, this pump features a four-piston design that ensures higher flow rates and consistent performance. Its integrated internal bypass mechanism effectively eliminates pulsating flow and reduces switch chatter, providing a smooth and quiet operation. The pump is also self-priming, capable of lifting water up to 2.4 meters vertically, and includes quick-connect plug-in ports for straightforward installation.

Flojet Quad DC Water System Pump with two quick-connect fittings

This image displays the Flojet Quad DC Water System Pump, a compact black unit designed for water transfer. The pump features a cylindrical motor housing on the left and a pump head with multiple ports on the right. Two quick-connect fittings, one straight and one elbow, are shown detached in the foreground, ready for installation. The pump's label, partially visible on the motor housing, indicates 'MOD: R4305', 'VOLTS 12 VOLTESE', 'AMPS 7.0 AMPS', 'FLOW 3.3GPM', and 'PRESS 25 PSI'.

Setup

Proper installation is crucial for optimal performance and longevity of your Flojet Quad DC Water System Pump. Follow these general guidelines:

  1. Mounting: Securely mount the pump in a dry, well-ventilated area, ensuring it is protected from direct water spray. The pump can be mounted in any position.
  2. Plumbing: Utilize the provided quick-connect plug-in ports for easy and secure hose connections. Ensure all connections are tight to prevent leaks. It is recommended to install a strainer on the inlet side to protect the pump from debris.
  3. Electrical Connections: Connect the pump to a 12-volt DC power source. Ensure correct polarity (red wire to positive, black wire to negative). Use appropriate gauge wiring and install a fuse or circuit breaker in the positive line as recommended by the manufacturer to protect the circuit.
  4. Priming: The pump is self-priming. Once plumbing and electrical connections are complete, open a faucet or valve on the discharge side to allow air to escape, then turn on the pump. It will prime itself within a few seconds.

Operating Instructions

The Flojet Quad DC Water System Pump is designed for automatic operation. Once installed and connected to a power source, the pump will activate when there is a demand for water (e.g., opening a faucet) and deactivate when the demand ceases. The internal bypass feature ensures a smooth, consistent flow of water without the typical pressure switch cycling found in other pumps, leading to quieter operation and extended pump life.

  • Ensure the water supply to the pump is always available when operating. Running the pump dry for extended periods can cause damage.
  • Monitor the system for any unusual noises or leaks during operation.

Maintenance

Regular maintenance helps ensure the longevity and efficient operation of your pump.

  • Inspect Connections: Periodically check all plumbing and electrical connections for tightness and signs of wear or corrosion.
  • Clean Strainer: If an inlet strainer is installed, regularly inspect and clean it to prevent debris from entering the pump and reducing flow.
  • Winterization: In freezing conditions, ensure the pump and entire water system are properly drained or protected with non-toxic antifreeze to prevent damage from ice expansion.
  • General Cleaning: Keep the exterior of the pump clean and free from dirt and debris.

Troubleshooting

Refer to the following table for common issues and their potential solutions:

ProblemPossible CauseSolution
Pump does not turn onNo power, blown fuse/tripped breaker, loose wiring, faulty switchCheck power supply, replace fuse/reset breaker, tighten connections, test switch.
Low flow or no flowClogged inlet strainer, air leak on suction side, kinked hose, low voltage, pump running dryClean strainer, check all suction connections for leaks, straighten hoses, verify voltage, ensure water supply.
Pulsating flow or rapid cycling (switch chatter)Air in system, restricted flow, pressure switch adjustment neededBleed air from system by opening faucets. Ensure discharge line is not restricted. For pressure switch adjustment: Remove the small cap on the end of the pump and carefully adjust the screw underneath to fine-tune the pressure setting.
Pump runs continuouslyLeak in system, faulty pressure switch, pump running dryCheck for leaks in plumbing. If no leaks, the pressure switch may need adjustment or replacement. Ensure adequate water supply.

Specifications

AttributeDetail
BrandFlojet
Model Number04405143A
Voltage12 Volts DC
Maximum Flow Rate3.3 Gallons Per Minute (GPM)
Maximum Lifting Height2.4 Meters
Item Weight3.9 Pounds
Product Dimensions (L x W x H)8"L x 5"W x 3"H
Power SourceDC
MaterialPolypropylene (PP)
ColorBlack
Included ComponentsWater Pump

Warranty and Support

For detailed warranty information, technical support, or service inquiries regarding your Flojet Quad DC Water System Pump, please refer to the official documentation provided by Flojet at the time of purchase or visit the manufacturer's official website. You may also find additional resources and a comprehensive PDF user manual here.

When contacting support, please have your pump's model number (04405143A) and serial number (if applicable) readily available.

Related Documents - 04405143A

Preview Flojet VersiJet Series Q451F-118S-2P Industrial Diaphragm Pump Datasheet
Technical datasheet for the Flojet VersiJet Series Q451F-118S-2P industrial diaphragm pump. Features include heavy-duty motor, self-priming, dry-run capability, and detailed hydraulic and electrical specifications.
Preview User Manual: Air Operated Doorway Foam Unit - DS5, DS5K, DS5V
Comprehensive user manual for the DS5, DS5K, and DS5V Air Operated Doorway Foam Units. Includes installation, operation, safety warnings, specifications, and troubleshooting.
Preview Flojet BevJet Compact Beverage Dispense Pump Installation and Operation Manual
Comprehensive guide for installing and operating the Flojet BevJet Compact beverage dispense pump, including specifications, features, troubleshooting, and warranty information.
Preview FLOJET G57C Series Industrial Air Driven Pump: Installation, Operation & Specifications
This document provides comprehensive installation, operation, and performance details for the FLOJET G57C Series Industrial Air Driven Pump. It covers product data, specifications, allowed/not allowed fluids, mounting, plumbing, operation, troubleshooting, parts, warranty, and return procedures.
Preview FLOJET 18555000 Portable RV Waste Pump Self-Priming Macerator: Instruction Manual
Instruction manual for the FLOJET 18555000 Portable RV Waste Pump Self-Priming Macerator. Details features, specifications, application, wiring, operation, disassembly, assembly, and parts for RV waste management.
Preview Flojet G56 Beerjet Pump Technical Specifications and Diagram
Detailed technical specifications and dimensional diagram for the Flojet G56 Beerjet pump, a product from Flojet, a xylem brand.