TES TES 1360A

TES 1360A Humidity/Temperature Meter User Manual

Model: TES 1360A

1. Introduction

The TES 1360A Humidity/Temperature Meter is a precision instrument designed for accurate measurement of temperature, relative humidity, and dew point temperature. It features a clear three-line LCD display for simultaneous viewing of measured values. The meter includes advanced functions such as adjustable alarm levels with visual and audio indications, and a memory function to store and recall up to 99 sets of data.

2. Safety Information

Please read and understand all safety instructions before operating the TES 1360A meter. Failure to follow these instructions may result in injury or damage to the device.

3. Product Overview

Familiarize yourself with the components of your TES 1360A Humidity/Temperature Meter.

TES 1360A Humidity/Temperature Meter with LCD display and controls

Figure 1: TES 1360A Humidity/Temperature Meter. This image shows the meter's main body, the sensor probe at the top, the LCD display, and various control switches and buttons for temperature, humidity, dew point, hold, power, and memory functions.

Key Components:

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment cover on the back of the meter.
  2. Slide or unclip the cover to open the compartment.
  3. Insert one 9V battery (006P 9V, IEC 6F22, or NEDA 1604 type) into the compartment, ensuring correct polarity (+/-). A 9V battery is included with the meter.
  4. Replace the battery compartment cover securely.

4.2 Initial Power On

After installing the battery, slide the ON/OFF switch to the "ON" position. The LCD display will illuminate and show current readings.

5. Operation

5.1 Taking Measurements

  1. Turn on the meter by sliding the ON/OFF switch to "ON".
  2. Position the sensor probe in the environment where you wish to take measurements. Allow a few moments for the readings to stabilize.
  3. The LCD will display the current temperature, relative humidity, and dew point temperature simultaneously.
  4. To change the primary displayed measurement (e.g., larger font), use the TEMP / %RH / DEW switch.
  5. To switch between Celsius (°C) and Fahrenheit (°F) temperature units, use the °C / °F switch.

5.2 Data Hold Function

To freeze the current readings on the display, slide the HOLD switch to the "HOLD" position. The readings will remain on the screen until the switch is moved back to "ON" or "OFF".

5.3 Data Memory Function

The meter can store up to 99 sets of measurement data.

5.4 Alarm Level Indication

The TES 1360A can compare measured values against two adjustable levels for each quantity (temperature, humidity, dew point). If a measured value exceeds or falls below these set levels, the corresponding value on the display will blink, and an audible alarm (if enabled) will sound. Consult the full manual for instructions on setting these alarm levels.

6. Maintenance

6.1 Cleaning

Wipe the meter's casing with a soft, damp cloth. Do not use harsh chemicals, solvents, or abrasive cleaners, as these can damage the plastic and electronic components. Ensure no liquid enters the sensor area or other openings.

6.2 Battery Replacement

When the battery indicator appears on the display, or if the meter fails to power on, replace the 9V battery as described in Section 4.1. Always dispose of used batteries responsibly according to local regulations.

6.3 Storage

If the meter will not be used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

ProblemPossible CauseSolution
Meter does not turn on.Dead or incorrectly installed battery.Check battery polarity. Replace with a new 9V battery.
Inaccurate readings.Sensor dirty or damaged; environmental interference; meter not calibrated.Clean the sensor carefully. Move away from strong electromagnetic fields. If issues persist, contact customer support for calibration or repair.
Display shows "LO" or "HI".Measurement is outside the meter's specified range.Ensure the environment's conditions are within the meter's operating range (see Specifications).
Memory function not working.Memory full; incorrect button press.Ensure you are pressing the correct button (MEMORY to save, READ to recall). If memory is full, consult the full manual for clearing instructions.

8. Specifications

General Specifications
BrandTES
ModelTES 1360A
Product Dimensions270mm(L) × 68mm(W) × 25mm(H) (approx. 10.63"H x 2.68"W)
Item WeightApprox. 210g (including battery) / 1.1 pounds
Power SupplySingle 9V Battery (006P 9V, IEC 6F22, or NEDA 1604)
Battery LifeApprox. 140 hours
Operating Temperature & Humidity0°C to 60°C (32°F to 140°F), below 95% RH (non-condensing)
Display StyleLCD
MaterialPlastic
AccessoriesInstruction manual, Battery, Carry case
Measurement Specifications
Humidity Measurement Range10% ~ 95% R.H.
Humidity Resolution0.1% R.H.
Humidity Accuracy
  • ±3%RH (at 25°C, 20 to 80% RH)
  • ±4%RH (at 25°C, 10 to 20% RH and 80 to 90% RH)
  • ±5%RH (at 25°C, 0 to 10% RH and 90 to 100% RH)
Temperature Measurement Range-20°C ~ +60°C (-4°F ~ +140°F)
Temperature Resolution0.1°C, 0.1°F
Temperature Accuracy
  • ±0.4°C (at +5°C to +60°C)
  • ±0.8°C (at -20°C to 5°C and +60°C to +80°C)
  • ±0.8°F (at +41°F to +140°F)
  • ±1.6°F (at -4°F to 41°F and +140°F to +176°F)

9. Warranty and Support

For specific warranty information regarding your TES 1360A Humidity/Temperature Meter, please refer to the documentation provided at the time of purchase or contact the seller directly. Warranty terms may vary based on region and retailer.

For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact TES customer support or the authorized distributor from whom you purchased the product. You can also visit the official TES store for more information: TES Official Store.

Related Documents - TES 1360A

Preview TES-1160/1161 Thermo-Hygro-Barometer: Features & Specifications
Explore the detailed features and technical specifications of the TES-1160 and TES-1161 Thermo-Hygro-Barometers. This versatile instrument measures temperature, humidity, and barometric pressure, with advanced data logging on the 1161 model.
Preview TES-1350A Sound Level Meter Instruction Manual
Instruction manual for the TES-1350A Sound Level Meter, covering safety information, features, specifications, calibration, and measurement procedures for accurate sound level monitoring.
Preview TES-2620 Auto-Ranging True RMS Multimeter Instruction Manual
Comprehensive instruction manual for the TES-2620 Auto-Ranging True RMS Digital Multimeter, covering safety information, features, specifications, parts and controls, measurement procedures, and battery/fuse replacement.
Preview TES-3600 3P4W Power Analyzer Instruction Manual
Comprehensive instruction manual for the TES-3600 3P4W Power Analyzer, covering safety information, specifications, operation, maintenance, and RS-232 interface.
Preview TES-1381K Handheld Water Quality Analyzer Datasheet
Technical specifications and features for the TES-1381K Handheld Water Quality Analyzer, including pH, conductivity, redox, TDS, salinity, and temperature measurements. Details on resolution, accuracy, accessories, and applications.
Preview TES-137 Luminance Meter - Reliable Quality Measurement
Detailed specifications and applications for the TES-137 Luminance Meter, offering dual display, wide measuring range, and advanced functions for professional lighting analysis.