1. Product Overview
The BACOENG P0097 is an automatic ON/OFF stainless steel water pressure booster pump designed for tankless water supply pressurization. It features a smart controller for real-time monitoring and automatic operation based on water usage.
Key Features:
- Automatic Operation: Cycles on and off as water is used and pressure drops, eliminating the need for a pressure tank.
- Smart Controller: Provides real-time water monitoring and automatically stops operation if the inlet pipe lacks water.
- Built-in Check Valve: Helps maintain pressure and prevents rapid starting and cycling of the system.
- Food Grade Standard: All components in contact with pumped liquid are constructed from Stainless Steel 304, ensuring hygiene and corrosion resistance.
- Durable Motor: Features built-in thermal overload protection for long-term stable service.
2. Product Components
Understanding the main components of your BACOENG P0097 pump is essential for proper installation and maintenance.


3. Specifications
| Parameter | Value |
|---|---|
| Voltage | 110V/60Hz |
| Horsepower (HP) | 0.6 HP |
| Inlet/Outlet Size | 1 inch NPT |
| Maximum Pressure | 6 Bar (approx. 87 PSI) |
| Maximum Flow Rate | 12 GPM (Gallons Per Minute) / 15.9 GPM (from specifications) |
| Suction Height | 29.5 ft |
| Maximum Lifting Height | 40.7 Feet |
| Material | Stainless Steel |
| Item Weight | 19.81 pounds |
| Product Dimensions | 16 x 8 x 14 inches |
| Model Number | P0097 |
4. Setup
Proper installation is crucial for the optimal performance and longevity of your booster pump. Ensure all connections are secure and leak-free.
Installation Steps:
- Identify the main water supply line where the booster pump will be installed. The pump is designed for direct installation in home water supply pipelines for tankless systems.
- Ensure the pump is placed on a stable, level surface.
- Connect the inlet and outlet pipes to the pump. The pump features 1-inch NPT connections. Use appropriate fittings and thread sealant (e.g., PTFE tape) to prevent leaks.
- Verify that all valves in the system are correctly positioned for water flow through the pump.
- Before initial operation, ensure the pump is primed by filling the pump head with water through the filling plug to prevent dry running.
- Connect the pump to a grounded 110V/60Hz power outlet.

Setup Demonstration Video:
This video demonstrates the installation process and shows the pump in operation, including how it automatically turns on when water is used and off when the water supply is closed.
5. Operating Instructions
The BACOENG P0097 pump is designed for automatic operation. Once installed and powered, it will activate when water flow is detected and deactivate when flow stops.
Automatic ON/OFF System:
The integrated smart controller monitors water usage. When a faucet or appliance demands water, the pressure in the system drops, and the pump automatically turns on to boost pressure. When water demand ceases, the pressure stabilizes, and the pump automatically turns off.

Indicator Lights and Restart Function:
The control panel features indicator lights to show the pump's status and a restart button for manual intervention if a fault occurs.

Safety Features:
The pump includes temperature sensing and automatic overload stop mechanisms to protect the motor from overheating and damage.

6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your BACOENG P0097 water pressure booster pump.
- Regular Inspection: Periodically check the pump and connections for any signs of leaks, corrosion, or damage. Address any issues promptly.
- Cleanliness: Keep the pump area clean and free from debris to ensure proper ventilation and prevent obstruction of moving parts.
- Winterization: In cold climates, drain the pump and associated piping to prevent freezing and damage during winter months. Use the drain plug for complete drainage.
- Priming: If the pump has been drained or if it runs dry, re-prime it by filling the pump head with water before restarting.
7. Troubleshooting
If you encounter issues with your BACOENG P0097 pump, refer to the following common troubleshooting steps:
- Pump Not Starting: Check if the power cord is securely plugged in and if there is power to the outlet. Ensure the pump is properly primed. If the red 'Failure' light is on, press the 'Restart' button.
- Low Water Pressure: Verify that the main water supply is fully open. Check for any blockages in the inlet or outlet pipes. Ensure the pump is not running dry.
- Pump Running Continuously: This may indicate a leak in your plumbing system or a faulty check valve. Inspect all connections for leaks and ensure no faucets are dripping.
- Excessive Noise: Ensure the pump is securely mounted and not vibrating against other surfaces. Check for air in the system; re-priming might be necessary.
- Leaks at Connections: Tighten all pipe connections. If using threaded connections, ensure sufficient thread sealant (PTFE tape) was applied during installation.
For persistent issues, contact BACOENG customer support.
8. Performance Test Video
This video provides a performance test of the BACOENG P0097 pump (referred to as EJm61C in the video) and another model, demonstrating their pressure and flow rate capabilities.
9. Warranty and Support
BACOENG products are designed for reliability and durability. For specific warranty information, please refer to the warranty card included with your product or visit the official BACOENG website. Keep your purchase receipt as proof of purchase for warranty claims.
For technical assistance, troubleshooting, or spare parts, please contact BACOENG customer support through their official channels. Provide your model number (P0097) and a detailed description of the issue for efficient service.