Welch Allyn 71000-A 3.5V Rechargeable Power Handle Instruction Manual

Model: 71000-A

Introduction

The Welch Allyn 71000-A is a 3.5V rechargeable power handle designed to provide portable power for compatible Welch Allyn diagnostic instrument heads. This manual provides essential information for the safe and effective use, setup, and maintenance of your power handle.

Welch Allyn 71000-A 3.5V Rechargeable Power Handle

An image showing the Welch Allyn 71000-A 3.5V Rechargeable Power Handle. It features a silver, textured grip and a chrome top section with a connection point for diagnostic instrument heads.

Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in injury or damage to the product.

Package Contents

Verify that all items are present in the package:

Setup

1. Charging the Handle

  1. Connect the IEC Plug Type-A charger to a standard electrical outlet.
  2. Insert the charger's plug into the charging port located at the bottom of the power handle.
  3. Allow the handle to charge for approximately 10-12 hours for the initial charge. Subsequent charges typically require 2-3 hours.
  4. A charging indicator light (if present) will illuminate during charging and may change color or turn off when fully charged. Refer to the specific charger's instructions for indicator behavior.

2. Attaching Instrument Heads

  1. Ensure the power handle is turned off.
  2. Align the base of the Welch Allyn 3.5V instrument head with the connector on the top of the power handle.
  3. Gently push the instrument head onto the handle and twist clockwise until it clicks securely into place.
  4. To remove, twist counter-clockwise and pull the instrument head off.

Operating

Powering On and Adjusting Brightness

  1. With an instrument head securely attached, locate the rheostat control (rotary switch) on the handle.
  2. Rotate the rheostat control clockwise to turn on the light and increase its brightness.
  3. Rotate the rheostat control counter-clockwise to decrease brightness and turn off the light.

Maintenance

Cleaning

Battery Care

Troubleshooting

ProblemPossible CauseSolution
Handle does not turn onBattery discharged; Instrument head not properly attachedRecharge the battery; Ensure instrument head is securely twisted into place
Light is dimLow battery charge; Rheostat set too lowRecharge the battery; Rotate rheostat clockwise to increase brightness
Handle not chargingCharger not properly connected; Faulty power outletVerify charger connection to handle and outlet; Try a different power outlet

Specifications

Warranty and Support

For detailed warranty information, technical assistance, or to inquire about replacement parts, please contact Welch Allyn customer service or visit the official Welch Allyn website. Keep your purchase receipt for warranty claims.

Related Documents - 71000-A

Preview Welch Allyn 3.5-Volt Rechargeable Battery Replacement and Usage Guide
Instructions for charging and replacing Welch Allyn 3.5-volt rechargeable batteries for models 71000, 71010, 71020, 71050, 70700, 70710, 70720, 70750. Includes important safety warnings.
Preview Welch Allyn 719 Series Lithium Ion Handle and USB Charging Accessory - Directions for Use
This document provides comprehensive directions for use for the Welch Allyn 719 Series Lithium Ion Handle and USB Charging Accessory. It includes introductory information, device details, charging instructions, operating guidelines, cleaning procedures, and important safety warnings.
Preview Welch Allyn 719 Series Lithium Ion Handle - Instructions for Use
Comprehensive instructions for use, safety warnings, specifications, and maintenance for the Welch Allyn 719 Series Lithium Ion Handle, designed for powering various 3.5V Welch Allyn medical instruments.
Preview Welch Allyn 719 Series Lithium Ion Handle - Instructions for Use
Comprehensive instructions for the Welch Allyn 719 Series Lithium Ion Handle, covering intended use, operation, charging, battery replacement, cleaning, specifications, safety warnings, and warranty information.
Preview Welch Allyn ProBP 2000 Digital Blood Pressure Device: Instructions for Use
This document provides comprehensive instructions for the Welch Allyn ProBP 2000 Digital Blood Pressure Device, covering setup, operation, maintenance, troubleshooting, and specifications for professional clinical use.
Preview Welch Allyn Spot Vital Signs Service Manual
Comprehensive service manual for the Welch Allyn Spot Vital Signs device, covering troubleshooting, repair, maintenance, specifications, and functional overviews for medical clinicians.