1. Introduction

This manual provides essential information for the proper use, installation, and maintenance of the DELFIELD 417-CR2-0003-S Tray Mhc Insert. This is a genuine OEM replacement part designed for commercial foodservice equipment, ensuring safety, reliability, and optimal performance.

DELFIELD has over 50 years of industry experience, providing high-quality components for various applications. Using genuine OEM parts is crucial for maintaining the integrity and functionality of your equipment.

Key Features:

  • Genuine OEM replacement part
  • Designed for commercial foodservice equipment
  • Ensures safety, reliability, and performance

2. Setup

The DELFIELD 417-CR2-0003-S Tray Mhc Insert is designed for straightforward installation into compatible commercial refrigeration units or equipment. Before installation, ensure the equipment is powered off and disconnected from its power source to prevent injury.

  1. Inspect the Insert: Carefully unpackage the tray and inspect it for any signs of damage during transit. Ensure all perforations are clear and the tray is free from bends or deformities.
  2. Prepare the Cavity: Identify the designated slot or cavity within your commercial refrigeration unit where the tray is to be inserted. Ensure the area is clean and free of debris.
  3. Insert the Tray: Gently slide the DELFIELD 417-CR2-0003-S Tray Mhc Insert into the prepared cavity. Ensure it sits flush and securely within its designated position. Do not force the tray if it encounters resistance; re-check alignment.
  4. Verify Fit: Once inserted, gently push and pull the tray to confirm it is stable and does not wobble. A proper fit is essential for efficient air circulation and product support.
Top-down view of the DELFIELD 417-CR2-0003-S Tray Mhc Insert, showing its perforated surface and raised edges.

Figure 1: The DELFIELD 417-CR2-0003-S Tray Mhc Insert, showcasing its design for optimal air flow.

3. Operating

The DELFIELD 417-CR2-0003-S Tray Mhc Insert functions as a support and air circulation component within commercial refrigeration systems. Its perforated design allows for consistent airflow around stored items, which is critical for maintaining proper temperatures and preserving product quality.

  • Loading: Place items evenly on the tray. Avoid overloading to ensure proper air circulation and prevent damage to the tray or the refrigeration unit.
  • Airflow: Do not block the perforations on the tray. Obstructed perforations can impede airflow, leading to inefficient cooling and potential temperature fluctuations within the unit.
  • Compatibility: This tray is specifically designed for certain DELFIELD Mhc-22 models. Ensure it is used with compatible equipment to guarantee optimal performance and fit.
Angled view of the DELFIELD 417-CR2-0003-S Tray Mhc Insert, highlighting the uniform perforations.

Figure 2: The tray's perforated surface, essential for maintaining consistent temperatures.

4. Maintenance

Regular cleaning and inspection of the DELFIELD 417-CR2-0003-S Tray Mhc Insert will extend its lifespan and ensure continued hygienic operation within your commercial foodservice environment.

  1. Cleaning:
    • Remove the tray from the unit.
    • Wash with warm, soapy water using a soft cloth or sponge. Avoid abrasive cleaners or scouring pads that could scratch the surface.
    • Rinse thoroughly with clean water.
    • Allow the tray to air dry completely or dry with a clean cloth before re-inserting into the unit.
  2. Inspection: Periodically inspect the tray for any signs of wear, corrosion, or damage. Check that the perforations remain clear and unobstructed. If significant damage is observed, consider replacing the tray to maintain optimal performance and hygiene.
Close-up angled view of the DELFIELD 417-CR2-0003-S Tray Mhc Insert, showing the texture of the metal.

Figure 3: Detail of the tray's metal surface, emphasizing the need for gentle cleaning.

5. Troubleshooting

This section addresses common issues that may arise with the DELFIELD 417-CR2-0003-S Tray Mhc Insert.

ProblemPossible CauseSolution
Tray does not fit into the unit.Incorrect model compatibility or obstruction in the slot.Verify the model number of your equipment against the tray's specifications. Check the slot for any debris or foreign objects. Ensure the tray is not bent or damaged.
Airflow seems restricted.Perforations are blocked by debris or items on the tray.Remove the tray and clean all perforations. Ensure items are not overloaded or placed directly over the holes when in use.
Tray appears damaged or corroded.Physical impact, improper cleaning agents, or prolonged exposure to harsh conditions.If the damage affects functionality or hygiene, the tray should be replaced with a new genuine OEM part. Follow recommended cleaning procedures.
Another angled view of the DELFIELD 417-CR2-0003-S Tray Mhc Insert, showing its overall dimensions and sturdy construction.

Figure 4: The robust construction of the tray, designed for durability in commercial settings.

6. Specifications

AttributeValue
BrandDELFIELD
Model NumberDEL417-CR2-0003-S
ASINB07233JD3J
UPC046852080272
Package Dimensions24 x 7 x 6 inches
Item Weight0.48 Pounds
Form FactorTray
Specification MetOEM
Date First AvailableMay 16, 2017

7. Warranty and Support

As a genuine OEM replacement part, the DELFIELD 417-CR2-0003-S Tray Mhc Insert is manufactured to high standards. Specific warranty details for this component are typically covered under the warranty of the larger DELFIELD equipment it is intended for, or by the distributor from whom it was purchased.

For detailed warranty information, technical support, or to inquire about replacement parts, please contact DELFIELD customer service or your authorized DELFIELD distributor. Always provide the model number (DEL417-CR2-0003-S) and the ASIN (B07233JD3J) when seeking support.

Manufacturer: Delfield

Related Documents - DEL417-CR2-0003-S

Preview Delfield 6000XL & 6100XL Series Reach-In Refrigerators and Freezers: Installation, Operation, and Maintenance Manual
Comprehensive manual for Delfield 6000XL and 6100XL Series Reach-In Refrigerators and Freezers, covering installation, operation, maintenance, and troubleshooting. Includes safety notices, technical specifications, and control system details.
Preview AIR-O-TRONICS Defrost Timer Programming Guide
User guide for the AIR-O-TRONICS Defrost Timer, detailing dip switch settings for defrost duration and cycle time, with operational sequences and wiring information.
Preview Delfield 200 & 300 Series: Installation, Operation, and Maintenance Manual
Comprehensive installation, operation, and maintenance manual for Delfield 200 & 300 Series commercial refrigerators and freezers. Covers safety, specifications, electrical, refrigeration, and cleaning procedures.
Preview Delfield 6000XL & 6100XL Series Reach-In Refrigerators and Freezers: Service, Installation, and Care Manual
This manual provides comprehensive service, installation, and care instructions for Delfield 6000XL and 6100XL Series Reach-In Refrigerators and Freezers. It covers specifications, operation, maintenance procedures, wiring diagrams, replacement parts, labor guidelines, and warranty information.
Preview Delfield FlexiWell - ShelleySteel Mobile Hot, Cold & Freeze Serving Counter Specifications
Detailed specifications, features, and options for the Delfield FlexiWell - ShelleySteel, a versatile mobile serving counter capable of hot, cold, and freeze food service applications. Includes model information, dimensions, and electrical specifications.
Preview Delfield F18 Series Service and Installation Manual
Comprehensive service and installation manual for Delfield F18 Series refrigerated work tables, salad tables, and freezer bases. Covers installation, operation, maintenance, troubleshooting, and parts.