1. Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinals. This module is designed to provide reliable, hands-free flushing for G2 Optima Plus flushometers, enhancing hygiene and water conservation in commercial and public restrooms.
2. Safety Information
Please read all safety instructions before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or improper product function.
- Always turn off the water supply before beginning any installation or maintenance.
- Ensure all electrical connections are made by a qualified electrician if applicable, and comply with local codes.
- Wear appropriate personal protective equipment (PPE) such as safety glasses and gloves.
- Do not attempt to modify the product. Use only genuine Sloan replacement parts.
- Keep children away from the installation area.
3. Package Contents
Verify that all components are present before beginning installation:
- Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module
- Mounting hardware (if applicable)
- Instruction sheet (this document)
Note: Additional components for the complete flushometer system are sold separately.
4. Setup and Installation
Installation should be performed by a qualified plumber or technician.
- Prepare the Urinal: Ensure the urinal and existing flushometer body are clean and free of debris. Turn off the main water supply to the urinal.
- Remove Existing Components: Carefully remove any old sensor modules or manual flush handles from the flushometer.
- Install the Sensor Module: Position the EBV129A-U module onto the flushometer body according to the specific G2 Optima Plus flushometer model's instructions. Ensure proper alignment and secure attachment.
- Connect Wiring (if applicable): If the module requires external power or data connections, connect them securely following the wiring diagram provided with your specific flushometer model. Ensure all connections are watertight.
- Restore Water Supply: Slowly turn on the water supply and check for leaks.
- Test Operation: Allow the sensor to calibrate for a few moments. Step away from the urinal, then approach it to trigger the sensor. The flushometer should activate automatically.

Figure 1: Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module. This image shows the compact electronic sensor module, typically installed on a urinal flushometer to enable automatic, hands-free flushing. It features a sensor window and connection points for integration with the flushometer system.
5. Operating Instructions
The Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module provides fully automatic, hands-free operation for urinals equipped with compatible G2 Optima Plus flushometers.
- Automatic Flushing: The sensor detects the user's presence and initiates a flush cycle after the user departs.
- Sensor Range: The sensor is factory-set for optimal detection range. Avoid placing objects directly in front of the sensor that could obstruct its view or cause false activations.
- Manual Override (if applicable): Some G2 Optima Plus flushometers may feature a manual override button. Refer to your specific flushometer's manual for details on this function.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your sensor module.
- Cleaning: Clean the sensor lens regularly with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the sensor surface.
- Battery Replacement (if battery-powered): If your G2 Optima Plus flushometer system uses batteries for the sensor module, replace them as indicated by a low battery indicator or when the flushometer stops responding. Refer to your flushometer's manual for specific battery type and replacement procedures.
- Inspection: Periodically inspect the module for any signs of damage or loose connections.
7. Troubleshooting
If you experience issues with your sensor module, consult the following table before contacting support.
| Problem | Possible Cause | Solution |
|---|---|---|
| No flush when user departs | Obstructed sensor lens, low battery (if applicable), water supply off, faulty module. | Clean sensor lens. Replace batteries. Check water supply valve. Contact Sloan support if problem persists. |
| Continuous flushing | Sensor obstruction, faulty sensor, internal flushometer issue. | Remove any objects near sensor. Check for reflective surfaces. Consult flushometer manual. Contact Sloan support. |
| Weak or incomplete flush | Low water pressure, partially closed stop valve, flushometer diaphragm issue. | Check water pressure. Ensure stop valve is fully open. Consult flushometer manual for diaphragm inspection. |
8. Specifications
- Model Number: DT-39901 (EBV129A-U)
- Brand: Sloan
- Material: Metal
- Exterior Finish: Stainless Steel
- Inlet Connection Size: 1 Inches
- Inlet Connection Type: Flange
- Outlet Connection Size: 2 Inches
- Outlet Connection Type: Valve Connection Type
- Number of Ports: 2
- Valve Type: Globe Valve
- Size: 1 inch x 2 inch
- Item Weight: 0.01 Ounces
- Specification Met: CSA, ULC
- UPC: 733353562306
9. Warranty and Support
Sloan products are manufactured to the highest standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty information included with your original flushometer purchase or visit the official Sloan website.
For technical assistance, replacement parts, or further inquiries, please contact Sloan Customer Support:
- Website: www.sloan.com
- Phone: Refer to the Sloan website for regional contact numbers.