This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your OSRAM Surface Circular LED Wall and Ceiling Light. Please read this manual thoroughly before installation and retain it for future reference. Proper installation and use are crucial for optimal performance and safety.

This LED fixture is designed for direct replacement of conventional lighting with 2x 18W or 2x 26W compact fluorescent lamps, offering enhanced energy efficiency and uniform light distribution.

2. Safety Instructions

  • Always disconnect power at the main circuit breaker before installation, maintenance, or cleaning.
  • Installation must be performed by a qualified electrician in accordance with all local and national electrical codes.
  • Do not modify the fixture in any way. Unauthorized modifications may void the warranty and create safety hazards.
  • Ensure the mounting surface is structurally sound and can support the weight of the fixture.
  • Do not look directly into the operating LED light source.
  • This product is rated IP44 for water protection, suitable for damp locations like bathrooms, but not for direct water exposure.
  • Operate within the specified ambient temperature range of -20°C to +40°C.

3. Product Features

  • LED wall and ceiling lighting fixture.
  • Available in 3000K warm white and 4000K cool white (this model is 3000K warm white).
  • 120° light beam angle for uniform illumination.
  • Energy efficient: Approximately 55% more efficient than conventional lighting.
  • Quick and easy installation.
  • LED protected for safe installation.
  • Durable metal housing in white with acrylic glass covering.
  • IP44 water protection rating.
  • Long lifespan: Up to 30,000 hours.
  • Certifications: CE, CB, TUEV SUED.

4. Setup and Installation

Before beginning installation, ensure all components are present and undamaged. Refer to the safety instructions in Section 2.

4.1 Package Contents

The package typically includes the LED fixture, mounting hardware, and this instruction manual. Inspect all items upon unboxing.

4.2 Mounting the Fixture

This fixture is designed for surface mounting on walls or ceilings. The 24W model has a diameter of 40 cm and a height of 12 cm.

OSRAM Surface Circular LED Wall and Ceiling Light, front view

Figure 1: Front view of the OSRAM Surface Circular LED Wall and Ceiling Light. This image shows the overall design of the circular fixture, suitable for both wall and ceiling installations.

  1. Prepare the Mounting Location: Choose a suitable location on the wall or ceiling. Ensure there is adequate space and that the electrical wiring is accessible.
  2. Mark Drilling Points: Use the fixture's mounting bracket as a template to mark the drilling points on the surface.
  3. Drill Holes: Drill holes at the marked points. Insert appropriate wall anchors if necessary (e.g., for drywall or plaster).
  4. Secure Mounting Bracket: Attach the mounting bracket to the wall or ceiling using the provided screws.

4.3 Electrical Connection

Ensure power is OFF at the circuit breaker before proceeding with electrical connections.

OSRAM Surface Circular LED Wall and Ceiling Light, side view

Figure 2: Side view of the OSRAM Surface Circular LED Wall and Ceiling Light. This image illustrates the depth and profile of the fixture, which is 12 cm high for the 24W model.

  1. Connect Wiring: Connect the household electrical wires to the fixture's terminals according to local wiring codes (Live to Live, Neutral to Neutral, Ground to Ground). Ensure all connections are secure.
  2. Attach Fixture to Bracket: Carefully align the fixture with the mounting bracket and secure it in place. Follow the specific attachment mechanism of your model (e.g., twist-lock, screws).
  3. Restore Power: Once the fixture is securely mounted and wired, restore power at the circuit breaker.

5. Operating Instructions

The OSRAM Surface Circular LED Wall and Ceiling Light operates by a standard wall switch. Once installed and power is restored, the light can be turned on and off using the connected switch.

OSRAM Surface Circular LED Wall and Ceiling Light, angled view

Figure 3: Angled view of the OSRAM Surface Circular LED Wall and Ceiling Light. This image provides a perspective of the fixture's design and how it might appear when installed.

6. Maintenance

The OSRAM Surface Circular LED fixture requires minimal maintenance.

  • Cleaning: Disconnect power before cleaning. Wipe the fixture with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or cleaners containing alcohol, as these can damage the finish or acrylic glass.
  • LED Replacement: The LEDs in this fixture are integrated and not user-replaceable. The fixture is designed for a long lifespan of up to 30,000 hours.
  • Inspection: Periodically inspect the fixture for any signs of damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.

7. Troubleshooting

Problem Possible Cause Solution
Light does not turn on. No power supply; loose wiring; faulty switch. Check circuit breaker. Ensure all wiring connections are secure. Test the wall switch.
Light flickers. Loose wiring connection; incompatible dimmer switch (if applicable, though this model is not specified as dimmable). Check wiring connections. Ensure the fixture is not connected to an incompatible dimmer.
Reduced light output. Dust or dirt on the diffuser. Clean the acrylic glass covering as per maintenance instructions.

If troubleshooting steps do not resolve the issue, contact a qualified electrician or OSRAM customer support.

8. Specifications

Attribute Value
BrandOSRAM
Model NumberFTG-2D-LEDVANCE24-3K
ManufacturerOsram Ledvance
Wattage24 watts
Light Source TypeLED
Color Temperature3000K (Warm White)
Luminous FluxUp to 1920 lm
Luminous EfficacyUp to 80 lm/W
Beam Angle120°
Diameter (24W)40 cm
Height (24W)12 cm
MaterialMetal housing, acrylic glass covering
IP RatingIP44 (Water protected)
Operating Temperature-20°C to +40°C
LifespanUp to 30,000 hours
Energy Efficiency ClassA+ (EU label)
CertificatesCE, CB, TUEV SUED
ASINB01MR9NPQ8

For detailed product data, refer to the official product information sheet available via the EPREL database: https://eprel.ec.europa.eu/qr/630394

9. Warranty and Support

For warranty information or technical support, please contact OSRAM customer service. Keep your purchase receipt as proof of purchase.

Manufacturer: Osram Ledvance

Website: http://www.ledvance.com/

Phone: +49 89-780673-100

Address: Parkring 29-33, 85748 Garching, Germany

© 2026 OSRAM. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.