Watt Stopper TS-200

Watt Stopper Digital Time Switch TS-200 Inteliswitch User Manual

Model: TS-200

1. Introduction

The Watt Stopper Digital Time Switch TS-200 Inteliswitch is an advanced wall-mounted timer designed to control lighting or other electrical loads. It features a digital display for easy programming and provides automated control based on user-defined schedules, enhancing energy efficiency and convenience.

2. Safety Information

WARNING: RISK OF ELECTRIC SHOCK. IMPROPER INSTALLATION CAN LEAD TO SERIOUS INJURY OR DEATH.

  • Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
  • Turn off power at the circuit breaker or fuse box before installing or servicing the device.
  • Ensure all wire connections are secure and properly insulated.
  • Do not install with wet hands or while standing on wet surfaces.
  • This device is intended for indoor use only.

3. Package Contents

Verify that all components are present before beginning installation:

  • Watt Stopper Digital Time Switch TS-200 Inteliswitch
  • Mounting Screws
  • Wire Nuts (optional, may be included)
  • Instruction Manual (this document)

4. Installation and Setup

Follow these steps carefully to install your TS-200 Inteliswitch.

4.1 Pre-Installation

  1. Turn off Power: Locate the circuit breaker controlling the switch location and turn it OFF. Verify power is off using a voltage tester.
  2. Remove Old Switch: Carefully remove the existing wall plate and switch from the wall box. Disconnect the wires, noting their connections.

4.2 Wiring Instructions

The TS-200 requires specific wiring connections. Refer to the diagram below and the wire labels on the device.

Watt Stopper TS-200 Inteliswitch with wiring

Image: Front view of the Watt Stopper TS-200 Inteliswitch, showing the digital display, control button, and exposed wiring (green, black, red, yellow) on the left side. The device is ivory-colored and designed for wall mounting.

  • Green Wire (GND): Connect to the ground wire from the wall box.
  • Black Wire (277V): Connect to the incoming line voltage (hot) wire from the wall box.
  • Red Wire: Connect to the load wire (to the light fixture or appliance).
  • Yellow Wire: Typically used for 3-way applications or specific control functions. Refer to detailed wiring diagrams for your specific setup. If not used, cap off securely.

Use wire nuts to secure all connections. Ensure no bare wire is exposed.

4.3 Mounting

  1. Carefully push the wired switch into the wall box.
  2. Secure the switch to the wall box using the provided mounting screws.
  3. Attach the wall plate (not included with the switch) over the switch.

4.4 Initial Power-Up

Once installation is complete, turn the power back ON at the circuit breaker. The device will undergo an initial warm-up period, which may take approximately 30 seconds, as indicated by the label on the device. The display should then illuminate.

5. Operation

The TS-200 Inteliswitch features a digital display and a central control button for interaction.

  • Manual ON/OFF: Press the central button briefly to manually toggle the connected load ON or OFF. This will override any active program until the next scheduled event.
  • Display: The digital display shows the current time, day, and operational status (e.g., ON/OFF, program mode).

6. Programming

Detailed programming instructions are typically accessed by pressing and holding the central button or a combination of button presses. Refer to the on-screen prompts for specific steps.

6.1 Setting Time and Date

Access the settings menu (usually by holding the main button). Use the button to navigate and adjust hours, minutes, day, month, and year. Confirm each setting to save.

6.2 Creating Schedules

The TS-200 allows for multiple ON/OFF programs. Navigate to the "Program" or "Schedule" menu. Select a program slot and set the desired ON time, OFF time, and the days of the week for the program to be active. Repeat for additional programs.

6.3 Operating Modes

The switch may offer various operating modes such as:

  • Automatic: Follows programmed schedules.
  • Manual: Stays ON or OFF until manually changed.
  • Random: Varies ON/OFF times slightly for a lived-in look (e.g., for security).
  • Holiday: Suspends normal programming for a set period.

Select the desired mode from the menu.

7. Maintenance

The TS-200 Inteliswitch requires minimal maintenance.

  • Cleaning: Wipe the surface with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Internal Battery: The device contains an internal battery to maintain time and program settings during power outages. This battery is typically long-lasting and not user-replaceable. If the device consistently loses settings after power interruptions, professional service may be required.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.No power at the circuit breaker; incorrect wiring; faulty device.Check circuit breaker. Verify wiring connections. If problem persists, consult an electrician.
Load does not turn ON/OFF as programmed.Incorrect program settings; manual override active; incorrect time/date.Review program settings. Check if manual override is active. Verify current time and date.
Display is blank or flickering.Power issue; internal fault.Check power supply. If flickering, power cycle the device (turn off/on at breaker). If problem persists, contact support.

9. Specifications

  • Model: TS-200
  • Brand: Watt Stopper
  • Voltage: 277V (as indicated on device wiring)
  • Type: Digital Time Switch
  • Color: Ivory
  • UPC: 791689997667
  • First Available: August 30, 2016

10. Warranty and Support

For warranty information and technical support, please refer to the official Watt Stopper website or contact their customer service department. Keep your purchase receipt as proof of purchase.

Website: www.wattstopper.com (Example link, verify actual site)

Customer Service: Refer to the manufacturer's website for contact details.

Related Documents - TS-200

Preview Watt Stopper LMDC-100 Occupancy Sensor Quick Start Guide & Installation
Quick start guide for the Watt Stopper LMDC-100 Digital Lighting Management Dual Technology Ceiling Mount Occupancy Sensor. Includes installation, specifications, coverage, and troubleshooting.
Preview UW-100-24 Ultrasonic Low Voltage Wall Switch Occupancy Sensor Installation Instructions
Installation instructions and specifications for the Watt Stopper UW-100-24 Ultrasonic Low Voltage Wall Switch Occupancy Sensor. Covers unit description, operation, adjustments, troubleshooting, and ordering information.
Preview Watt Stopper WS-250 Occupancy Sensor: Features, Specifications, and Applications
Detailed information on the Watt Stopper WS-250 Passive Infrared Wall Switch Occupancy Sensor, including its features, specifications, applications, and installation guidance for energy-efficient lighting control.
Preview Wattstopper DT-205 Dual Technology Occupancy Sensor Installation and Operation Manual
Comprehensive guide for installing, wiring, adjusting, and troubleshooting the Wattstopper DT-205 Dual Technology Low Voltage Occupancy Sensor. Features PIR and ultrasonic detection for efficient lighting control.
Preview Wattstopper HS-150 Line Voltage Card Key Switch Installation Instructions
Installation guide for the Wattstopper HS-150 Line Voltage Card Key Switch, detailing specifications, operation, wiring, and troubleshooting for hotel room power control.
Preview Wattstopper Lighting Integrator Panel Installation Instructions
Comprehensive installation and setup guide for the Wattstopper Lighting Integrator Panel (LI8, LI24, LI48) by Legrand, covering component identification, wiring, low-voltage connections, smartwiring, testing, and troubleshooting.