DSC HSM2208

DSC PowerSeries NEO HSM2208 Low Current Output Module User Manual

1. Introduction

The DSC PowerSeries NEO HSM2208 is a low current output module designed to expand the programmable output capabilities of compatible DSC PowerSeries NEO security control panels. This module provides eight additional programmable outputs (PGMs) for integrating various external devices such as relays, sirens, or indicator lights into your security system.

This manual provides detailed instructions for the proper installation, configuration, and maintenance of the HSM2208 module to ensure optimal performance and system integration.

DSC PowerSeries NEO HSM2208 Low Current Output Module circuit board

An image showing the DSC PowerSeries NEO HSM2208 Low Current Output Module, featuring its blue circuit board, various electronic components, and a white terminal block for connections.

2. Safety Information

Please read and understand all safety instructions before installing or operating the HSM2208 module. Failure to follow these instructions may result in injury, damage to the product, or improper operation.

3. Package Contents

Verify that all items are present in the package before proceeding with installation:

4. Specifications

ManufacturerDSC
ModelHSM2208
CompatibilityDSC PowerSeries NEO HS2016, HS2032, HS2064, HS2128 Control Panels
Output Type8 Programmable Low Current Outputs (PGMs)
Operating Voltage12 Volts (DC)
MaterialCopper (circuit board)
Dimensions (Approx.)5.67 x 3.23 x 1.46 inches (Package)
Weight (Approx.)2.08 ounces

5. Setup and Installation

5.1 Pre-installation Checklist

5.2 Mounting the Module

The HSM2208 module is typically mounted within the main control panel enclosure or a separate auxiliary enclosure. Choose a secure location that is protected from environmental factors and allows for proper wiring.

  1. Identify suitable mounting holes within the enclosure.
  2. Secure the HSM2208 module using appropriate screws or standoffs. Ensure the module is firmly attached to prevent movement.

5.3 Wiring Connections

The HSM2208 module connects to the PowerSeries NEO control panel via the Corbus (Keybus) terminals. It also provides terminals for connecting external devices to its programmable outputs.

  1. Corbus Connection: Connect the HSM2208 module's Corbus terminals to the corresponding Corbus terminals on the PowerSeries NEO control panel. Ensure correct polarity:
    • Red to Red (+12VDC)
    • Black to Black (Ground)
    • Yellow to Yellow (Data)
    • Green to Green (Data)
  2. Programmable Output (PGM) Connections: Connect external devices to the PGM terminals (PGM1-PGM8) as required. Each PGM output is a low current output and typically switches to ground when activated. Refer to the external device's documentation for specific wiring requirements.
    • Ensure that the current draw of any device connected to a PGM output does not exceed the module's specified limits.
    • For higher current applications, an external relay must be used, controlled by a PGM output.

After all wiring is complete, carefully inspect all connections for accuracy and security before restoring power to the control panel.

6. Operating and Configuration

The HSM2208 module's programmable outputs are configured and controlled through the connected PowerSeries NEO control panel's programming menu. The module itself does not have user-operable controls.

  1. Module Enrollment: After installation and power-up, the control panel should automatically detect the HSM2208 module. Verify its enrollment in the control panel's system information or module supervision section.
  2. PGM Output Programming: Access the PowerSeries NEO control panel's programming menu (typically Installer Programming) to assign specific functions to each of the eight PGM outputs on the HSM2208 module.
    • Common PGM functions include siren activation, strobe light activation, relay control for garage doors or lights, and status indicators.
    • Refer to the specific PowerSeries NEO control panel's programming manual for detailed instructions on PGM output assignment, activation conditions, and timing.
  3. Testing: After programming, thoroughly test each PGM output to ensure it functions as intended with the connected external device.

7. Maintenance

The DSC PowerSeries NEO HSM2208 module is designed for reliable operation and requires minimal maintenance.

8. Troubleshooting

If you encounter issues with the HSM2208 module, consider the following troubleshooting steps:

8.1 Module Not Responding or Not Detected

8.2 PGM Output Not Activating

If issues persist after troubleshooting, contact your authorized DSC dealer or technical support.

9. Warranty and Support

Warranty Information: For detailed warranty terms and conditions applicable to the DSC PowerSeries NEO HSM2208 Low Current Output Module, please refer to the warranty documentation provided with your original purchase or contact your authorized DSC dealer.

Technical Support: Technical assistance for the HSM2208 module is available through your authorized DSC security system installer or dealer. You may also find additional resources, FAQs, and support contact information on the official DSC website.

Related Documents - HSM2208

Preview DSC PowerSeries NEO PGM Command Output 1-4 Programming and Function
Guide to programming and utilizing PGM Command Output 1-4 functions on DSC PowerSeries NEO alarm systems (HS2016, HS2032, HS2064, HS2128 v1.37+), covering types, programming syntax, current draw, and module compatibility.
Preview DSC PowerSeries neo PGM Command Output Programming Guide
Learn how to program PGM Command Outputs (1-4) for DSC PowerSeries neo alarm systems, including HS2016, HS2032, HS2064, HS2128 models. Details on wiring, current draw, and programming sections.
Preview PowerSeries Neo HS2016/HS2032/HS2064/HS2128 Alarm Panel User Guide
User guide for the PowerSeries Neo alarm panel series, covering system operation, keypad functions, arming/disarming, access codes, testing, and safety instructions. Includes model numbers HS2016, HS2032, HS2064, HS2128 and their variants.
Preview DSC PowerSeries Neo Alarm Panel User Manual
Comprehensive user manual for DSC PowerSeries Neo HS2016, HS2032, HS2064, HS2128 series alarm panels. Learn about system operation, arming/disarming, emergency functions, access codes, troubleshooting, and safety guidelines for your security system.
Preview DSC PowerSeries Neo Security System User Manual
Comprehensive user manual for the DSC PowerSeries Neo HS2016, HS2032, HS2064, and HS2128 series alarm panels. Learn how to operate, arm, disarm, and maintain your security system, including keypad functions, emergency features, and user management.
Preview DSC PowerSeries Neo Alarm Panel User Guide
Comprehensive user guide for the DSC PowerSeries Neo alarm panel series, covering system operation, arming/disarming, access codes, trouble conditions, safety instructions, and regulatory information.