Minka Lavery 4875-283

Minka Lavery Camden Square Mini Chandelier (Model 4875-283) Instruction Manual

Aged Charcoal Finish with Clear Seeded Glass

Important Safety Information

Please read these instructions carefully before beginning installation. Failure to follow these instructions could result in electrical shock, fire, or other hazards that could cause injury or property damage.

Package Contents

Verify that all components are present before beginning assembly. If any part is missing or damaged, do not attempt to assemble or install the fixture.

Note: Light bulbs are not included. This fixture requires four (4) B10.5 Candelabra Base (E12) bulbs, maximum 60 watts each.

Installation Instructions

Follow these steps carefully to install your Minka Lavery Camden Square Mini Chandelier.

1. Prepare for Installation

  1. Turn off the electrical power at the main fuse or circuit breaker box.
  2. Clear the work area and gather necessary tools (screwdriver, wire strippers, electrical tape, ladder).
  3. Carefully unpack the fixture and its components.

2. Mount the Fixture

  1. Attach the mounting bracket from the hardware kit to the junction box in the ceiling. Ensure it is securely fastened.
  2. Determine the desired hanging height for the chandelier. The fixture's height can be adjusted from 23.5 inches to 94 inches. Adjust the chain length accordingly by removing links if necessary.
  3. Thread the electrical wire through the chain and the canopy.
  4. Connect the chain to the fixture loop and the canopy loop.

3. Wire the Fixture

  1. Connect the fixture's bare copper or green ground wire to the house supply ground wire (usually bare copper or green) using a wire connector.
  2. Connect the fixture's white wire to the house supply white (neutral) wire using a wire connector.
  3. Connect the fixture's black wire to the house supply black (hot) wire using a wire connector.
  4. Carefully tuck all wires into the junction box.
  5. Secure the canopy to the mounting bracket, ensuring it sits flush against the ceiling.

4. Install Light Bulbs

  1. Screw four (4) B10.5 Candelabra Base (E12) bulbs (not included) into the sockets. Do not exceed the maximum wattage of 60 watts per bulb.

5. Restore Power

  1. Turn the electrical power back on at the main fuse or circuit breaker box.
  2. Test the fixture to ensure proper operation.
Minka Lavery Camden Square Mini Chandelier, Aged Charcoal finish with clear seeded glass panels, hanging from a chain.

Figure 1: Minka Lavery Camden Square Mini Chandelier (Model 4875-283) installed.

Operating Instructions

Once installed and powered, the Minka Lavery Camden Square Mini Chandelier operates via a standard wall switch connected to the fixture's circuit. Ensure the correct type and wattage of bulbs are used for optimal performance and safety.

Maintenance

Regular maintenance will help preserve the appearance and functionality of your chandelier.

Troubleshooting

If you experience issues with your chandelier, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Light does not turn on.
  • No power to the fixture.
  • Loose wire connections.
  • Defective bulb(s).
  • Faulty wall switch.
  • Check circuit breaker or fuse.
  • Verify all wire connections are secure (ensure power is off before checking).
  • Replace bulb(s).
  • Test wall switch or consult an electrician.
Light flickers.
  • Loose bulb.
  • Loose wire connection.
  • Incorrect bulb type or wattage.
  • Tighten bulb(s).
  • Check wire connections (ensure power is off before checking).
  • Ensure bulbs are B10.5 Candelabra Base (E12) and do not exceed 60 watts.

If problems persist after attempting these solutions, contact a qualified electrician for assistance.

Specifications

Model Number4875-283
BrandMinka Lavery
Dimensions (Fixture)19.5" High x 15.5" Wide
WeightApproximately 14.57 lbs
Ceiling Cover Dimensions5" Wide x 0.75" High
Adjustable Height Range23.5" to 94"
Number of Lights4
Max Wattage per Bulb60 Watts
Total Max Wattage240 Watts
Bulb Base TypeB10.5 Candelabra Base (E12)
Voltage120 Volts
FinishAged Charcoal
Shade MaterialClear Seeded Glass
Chain Length72 inches
Wire Length120 inches
Indoor/Outdoor UseIndoor Only
CertificationsETL Approved (US and Canada)
Assembly RequiredYes

Warranty and Support

Minka Lavery products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your purchase or visit the official Minka Lavery website.

For further assistance, you may contact Minka Lavery customer service directly. Keep your purchase receipt and model number (4875-283) handy for quicker service.

Online Resources: Visit the Minka Lavery Store on Amazon

Related Documents - 4875-283

Preview Minka Lavery 4046-84 Chandelier Installation Instructions
Detailed installation guide for the Minka Lavery 4046-84 6-Light Brushed Nickel Candlestick Chandelier with Clear Glass Shades. Includes safety warnings, mounting, wiring, and finishing steps.
Preview Minka Lavery 2430-84/878 Pendant Light Installation Guide
Comprehensive installation instructions for the Minka Lavery 2430-84/878 pendant light, covering mounting, wiring, and finishing steps for safe and proper setup.
Preview Minka Lavery 1457-695 Installation Instructions
Detailed installation instructions for the Minka Lavery 1457-695 chandelier. This guide covers preparation, fixture assembly, electrical wiring, and final completion steps. Includes safety warnings, diagram descriptions, and part identification for a successful installation.
Preview Minka Lavery 8694-61 Harrison Outdoor Pendant Installation Instructions
Step-by-step installation guide for the Minka Lavery 8694-61 Harrison outdoor pendant light fixture, including preparation, wiring, and completion steps. Safety warnings and product specifications are provided.
Preview Minka Lavery 2756-694 Chandelier Installation Guide
Comprehensive installation guide for the Minka Lavery 2756-694 outdoor chandelier, detailing assembly, hanging, wiring, and finishing steps with safety warnings and bulb specifications.
Preview Minka Lavery 2792-695 Installation Instructions
Step-by-step installation guide for the Minka Lavery 2792-695 vanity light fixture, including mounting, wiring, and finishing the installation. Safety warnings and bulb specifications are provided.