Dimplex 5045172295538

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Dimplex Electric Heater On/Off Switch (Set of 3) Instruction Manual

Model: 5045172295538

1. Product Overview

This document provides essential instructions for the safe and effective use of the Dimplex Electric Heater On/Off Switch. This set of three switches is designed as an authentic replacement part for various Dimplex electric heater models. Please read this manual thoroughly before installation and operation.

Dimplex Electric Heater On/Off Switch, top view

Image 1.1: Top view of the Dimplex Electric Heater On/Off Switch. This image shows the black rocker switch with a smooth surface, ready for installation.

2. Safety Information

  • Electrical Hazard: Always disconnect power to the heater unit at the main circuit breaker before attempting any installation, maintenance, or repair. Failure to do so can result in electric shock, injury, or death.
  • Qualified Personnel: Installation and replacement should ideally be performed by a qualified electrician or a competent person familiar with electrical wiring.
  • Correct Voltage: Ensure the switch's specifications (16A 250V AC) match the requirements of your heater.
  • Authentic Parts: Use only genuine Dimplex replacement parts to ensure compatibility and safety.
  • Environmental Conditions: The switch has an IP54 rating, indicating protection against dust and splashing water. Do not expose to direct water jets or immerse in water.

3. Setup and Installation

Follow these steps carefully to replace the on/off switch in your Dimplex electric heater. If you are unsure about any step, consult a qualified professional.

  1. Disconnect Power: Turn off the main power supply to the electric heater at the circuit breaker. Verify that the power is off using a voltage tester.
  2. Access Switch: Carefully open the heater casing or access panel to reach the existing on/off switch. Refer to your heater's specific manual for instructions on accessing internal components.
  3. Note Wiring: Before disconnecting, take a clear photograph or draw a diagram of the existing wiring connections to the switch terminals. This is crucial for correct re-installation.
  4. Remove Old Switch: Disconnect the wires from the old switch. Note how the switch is secured (e.g., clips, screws) and remove it from its mounting.
  5. Install New Switch: Insert the new Dimplex on/off switch into the mounting hole. Ensure it clicks securely into place.
  6. Connect Wiring: Reconnect the wires to the terminals of the new switch according to your diagram or photograph. Ensure all connections are secure and tight.
  7. Secure Casing: Close and secure the heater casing or access panel.
  8. Restore Power: Turn the main power supply back on at the circuit breaker.
  9. Test Functionality: Test the new switch to ensure the heater turns on and off correctly.
Dimplex Electric Heater On/Off Switch, side view with terminals

Image 3.1: Side view of the switch, showing the two metal terminals for electrical connections. These terminals are where the heater's wiring will be attached.

4. Operating Instructions

The Dimplex On/Off Switch operates as a standard rocker switch to control the power supply to your electric heater.

  • To Turn On: Press the side of the rocker switch marked with a power symbol (Power symbol on switch) or 'I' (if applicable) to the 'ON' position. The heater should receive power and begin operation according to its own controls.
  • To Turn Off: Press the opposite side of the rocker switch to the 'OFF' position. This will cut the power supply to the heater.
Dimplex Electric Heater On/Off Switch with power symbol

Image 4.1: Switch with a power symbol, typically indicating the 'ON' position.

Dimplex Electric Heater On/Off Switch with 'I' marking

Image 4.2: Switch with 'I' marking, typically indicating the 'ON' position.

5. Maintenance

The Dimplex On/Off Switch requires minimal maintenance to ensure long-term performance.

  • Cleaning: Periodically wipe the surface of the switch with a soft, dry cloth to remove dust and debris. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Inspection: Regularly inspect the switch for any signs of physical damage, such as cracks, discoloration, or loose connections. If any damage is observed, disconnect power and replace the switch immediately.
  • Environmental Protection: Ensure the switch is not exposed to conditions beyond its IP54 rating (e.g., heavy rain, immersion).

6. Troubleshooting

If you experience issues with your Dimplex On/Off Switch, consider the following troubleshooting steps:

  • Switch Does Not Operate:
    • Check if the main power supply to the heater is active at the circuit breaker.
    • Ensure the switch is correctly wired and all connections are secure.
    • Verify that the heater itself is functioning correctly (e.g., check its internal fuse or other controls).
  • Switch Feels Loose or Damaged:
    • Immediately disconnect power to the heater.
    • Inspect the switch for physical damage or if it has come loose from its mounting.
    • If damaged, replace the switch with a new, authentic Dimplex part.
  • Persistent Issues: If troubleshooting steps do not resolve the problem, or if you are uncomfortable performing electrical checks, contact a qualified electrician or Dimplex customer support for assistance. Do not attempt repairs beyond your expertise.

7. Specifications

BrandDimplex
Model Number5045172295538
Power Rating2 KW (Kilowatts)
Dimensions (L x W x H)10 x 12 x 1.5 cm
Weight30 grams
International Protection (IP) RatingIP54 (Protected from dust and splashing water)
Voltage/Current Rating16A 250V AC

8. Compatible Heater Models

This Dimplex On/Off Switch is compatible with a range of Dimplex electric heater models, including but not limited to:

  • 017024 BFD20 Brayford Stove
  • 046284 BFD20N Brayford Stove 2 kW FSC certified
  • 017031 BFD20R
  • 017420 CHERITON CHT20
  • 027931 CHT20LE CHERITON LED
  • 027733 CLB20R CLUB REMOTE
  • 024183 CAST. ILLO CST20
  • 019158 JAZZ (JAZ20)
  • 031198 JAZZ remote (JAZ20R)
  • 017673 LAGAN INSET FIRE
  • 017901 MON20R MONTANA
  • 022660 MON20W
  • WICKES MONTANA
  • 020963 MOZART MZT20
  • 020925 PUCCINI PCN20
  • 017895 RECTORY REC20R
  • 014269 RIT20 RITZ
  • 017048 SBN20 SPRINGBORNE
  • 046406 SPRINGBORNE SBN20N
  • 027740 SPRINGBORNE SBN20R
  • 014535 SHB20LC SHERBORNE LC
  • 020970 STRAUSS STS20
  • 019141 TANGO TNG20
  • 031204 TANGO REMOTE TNG20R
  • 026729 VERDI (VER20W)
  • 026279 ZAMORA ZAM20

If your heater model is not listed, please verify compatibility with Dimplex or your heater's documentation before purchase and installation.

9. Warranty and Support

Specific warranty information for this replacement part is not provided in the product details. For warranty inquiries, technical support, or further assistance, please contact Dimplex directly through their official website or customer service channels.

Always ensure you are using authentic Dimplex parts for safety and optimal performance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.