This user manual provides essential information for the safe and effective use of your Dimplex Genuine Electric Fire Heater On/Off Switch. This component is designed to replace or repair the power switch in various Dimplex electric fire heater models, ensuring proper functionality and safety.

2. Safety Information

WARNING: Electrical work should only be performed by a qualified and competent person. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect the main power supply to the appliance before attempting any installation, maintenance, or repair.
  • Ensure the replacement switch is compatible with your specific Dimplex heater model. Refer to the product listing or your appliance's original manual for compatibility.
  • Do not operate the appliance if the switch or any other electrical component is damaged.
  • Keep children and pets away from the appliance during installation and operation.
  • Ensure all connections are secure and properly insulated after installation.

3. Product Overview

The Dimplex Genuine Electric Fire Heater On/Off Switch is a robust replacement part designed for durability and reliable performance. It features a push-button actuator with a clear ON/OFF operation mode, typically indicated by a red section for the 'ON' position.

3.1 Compatible Models

This switch is compatible with a wide range of Dimplex electric fire heater models. Due to the extensive list, please refer to the original product listing or your appliance's specific model number for full compatibility details. Examples of compatible series include, but are not limited to: CHROME DNV20CH, EXBURY EBY15, ELDA ELD20, EMSWORTH EMS20, FERNDOWN FND20, LANGLEY FPL20, AVON FPS20, GOSFORD GOS20, HARCOMBE HAR20, HIGHCLIFFE HCF20, HOLBURY HOL20, HORTON HTN20, IMP IMP20, INVER INV20, IOWA IOW20W, LONGHAM LGM20, LINCOLN LIN20, LULWORTH LUL20, LOXLEY LXY15, MICHIGAN MCN20, MERIDA MDA20, and many others.

3.2 Product Images

Dimplex Electric Fire Heater On/Off Switch - Front View

Figure 1: Front view of the Dimplex Electric Fire Heater On/Off Switch, showing the black housing and the red/black push-button actuator.

Dimplex Electric Fire Heater On/Off Switch - Rear View with Terminals

Figure 2: Rear view of the switch, illustrating the two flat metal screw-in terminals for electrical connections.

Dimplex Electric Fire Heater On/Off Switch - Side View

Figure 3: Side view of the switch, providing a perspective on its compact design and mounting points.

4. Installation Guide

This guide provides general steps for replacing the switch. Specific procedures may vary depending on your appliance model. Always consult your appliance's service manual or a qualified electrician.

  1. Disconnect Power: Ensure the electric fire heater is unplugged from the mains power supply or the circuit breaker is switched off. Verify there is no power using a voltage tester.
  2. Access Switch: Carefully open the casing of your Dimplex electric fire heater to gain access to the existing On/Off switch. This may involve removing screws or clips.
  3. Note Wiring: Before disconnecting, take a clear photograph or make a diagram of how the wires are connected to the existing switch. Note the color and position of each wire.
  4. Disconnect Old Switch: Carefully disconnect the wires from the old switch. If screw terminals are used, loosen the screws and remove the wires.
  5. Remove Old Switch: Unclip or unscrew the old switch from its mounting position.
  6. Install New Switch: Insert the new Dimplex switch into the mounting hole, ensuring it clicks securely into place or is screwed down.
  7. Connect Wiring: Connect the wires to the new switch's terminals exactly as noted in step 3. Ensure all connections are tight and secure.
  8. Secure Casing: Carefully reassemble the heater casing, ensuring no wires are pinched and all screws/clips are properly secured.
  9. Restore Power: Plug the heater back into the mains supply or switch on the circuit breaker.
  10. Test Functionality: Test the new switch to ensure the heater turns on and off correctly.

5. Operation

The Dimplex Electric Fire Heater On/Off Switch operates as a simple toggle mechanism:

  • To turn the electric fire heater ON, press the side of the switch that typically features a red indicator or is marked 'I' (for 'On').
  • To turn the electric fire heater OFF, press the opposite side of the switch that typically features a black indicator or is marked 'O' (for 'Off').

Ensure the switch clicks firmly into position for reliable operation.

6. Maintenance

Regular maintenance helps ensure the longevity and safe operation of your switch:

  • Cleaning: Periodically wipe the exterior of the switch with a soft, dry cloth. Do not use abrasive cleaners or liquids directly on the switch.
  • Inspection: Annually, or if you notice any issues, inspect the switch for signs of wear, damage, or loose connections. If any damage is observed, disconnect power immediately and replace the switch.
  • Professional Check: Consider having your electric fire heater and its components, including the switch, inspected by a qualified technician every few years.

7. Troubleshooting

If you experience issues with your Dimplex Electric Fire Heater On/Off Switch, consider the following common troubleshooting steps:

  • Heater Not Turning On:
    • Check if the main power supply to the heater is connected and active.
    • Ensure the switch is fully depressed into the 'ON' position.
    • Inspect the wiring connections to the switch for looseness or corrosion (with power disconnected).
    • If the switch feels loose or doesn't click, it may be faulty and require replacement.
  • Heater Not Turning Off:
    • Ensure the switch is fully depressed into the 'OFF' position.
    • If the switch remains stuck or the heater continues to operate, the switch may be faulty. Disconnect power immediately at the mains.
  • Burning Smell or Smoke:

    Immediately disconnect power to the heater at the mains. Do not attempt to operate the appliance. Contact a qualified electrician or Dimplex customer support.

For persistent issues or complex electrical problems, it is strongly recommended to consult a qualified electrician or Dimplex customer support.

8. Specifications

Feature Detail
Brand Dimplex
Operation Mode ON-OFF
Contact Type Normally Closed
Connector Type Screw In
Terminal Screw
Circuit Type 1-way
Mounting Type Surface Mount
Actuator Type Push Button
Contact Material Brass
Controller Type Push Button
Package Dimensions 15 x 10 x 5 cm
Power / Wattage 2E+3 (2000W)

9. Warranty and Support

For information regarding warranty coverage, returns, or technical support for your Dimplex Genuine Electric Fire Heater On/Off Switch, please refer to the original purchase documentation or contact Dimplex customer service directly. Contact details can typically be found on the official Dimplex website or within your appliance's original user manual.

For general inquiries, you may visit the official Dimplex store on Amazon: Dimplex Store

Related Documents - Electric Fire Heater On Off Switch

Preview Dimplex 2kW DC Ceramic Tower Heater DHCH20E Instruction Manual
Instruction manual for the Dimplex 2kW DC Ceramic Tower Heater with Electronic Controls (Model DHCH20E). Includes safety precautions, operation, specifications, cleaning, storage, maintenance, warranty, and recycling information.
Preview Dimplex Futurad Heater: FutM2CE & FutM3CE User Manual and Safety Guide
Comprehensive user manual for Dimplex Futurad heaters (models FutM2CE and FutM3CE). Covers safety instructions, operation, assembly, features like runback timer and frost protection, technical specifications, and warranty information.
Preview Dimplex Alta WiFi Panel Heater: Installation, Operation, and Guarantee
Official installation and operating instructions for the Dimplex Alta WiFi Panel Heater (Model 300002588). Includes safety advice, technical specifications, energy efficiency data, quick start guide, app connectivity, and warranty information.
Preview Dimplex Optiflame Stove Fire Tango TNG20 Operating Manual
Operating instructions and safety information for the Dimplex Optiflame Stove Fire, Model Tango TNG20. Includes details on controls, thermostat, remote operation, maintenance, and technical specifications.
Preview Dimplex Helmsdale HLM20 Optiflame Inset Fire: Installation, Care & FAQ
Comprehensive guide to installing, operating, and maintaining the Dimplex Helmsdale HLM20 Optiflame Inset Electric Fire. Includes remote control functions, cleaning tips, and warranty information.
Preview Dimplex Optiflame LED Inset Fire Installation and Operation Guide
Comprehensive guide for installing, operating, and maintaining the Dimplex Optiflame LED Inset Fire. Includes safety advice, technical specifications, and troubleshooting tips.