Hantek TOL_OCSP_1008B

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Hantek 1008B Automotive Diagnostic Oscilloscope User Manual

Model: TOL_OCSP_1008B

1. Introduction

The Hantek 1008B is an 8-channel automotive diagnostic oscilloscope, DAQ card, and programmable generator designed for comprehensive vehicle testing. It offers over 80 types of automotive diagnostic functions, including ignition, sensor, bus detection, performance, and starter/charging circuit analysis. This device provides video help functions, allows for diagnostic report generation, and supports long-term waveform recording. It can also simulate camshaft and crankshaft signals, making it a versatile tool for automotive technicians.

2. What's in the Box

Upon unboxing your Hantek 1008B, please verify that all components are present:

  • Hantek 1008B Unit
  • USB Cable
  • 8 BNC to Alligator Clip Cables
  • Ignition Probe
  • CD with Software and Drivers
  • Assorted Accessories (e.g., test leads, probes, color rings)
Hantek 1008B kit with oscilloscope, cables, and accessories in a carrying case

Image: Complete Hantek 1008B kit including the main unit, carrying case, various cables, an ignition probe, and a software CD.

Hantek 1008B oscilloscope unit with BNC inputs on one side

Image: Front view of the Hantek 1008B oscilloscope unit, showing the eight BNC input channels.

Hantek 1008B oscilloscope unit with USB port and other connectors on the side

Image: Side view of the Hantek 1008B oscilloscope unit, highlighting the USB connection port and other auxiliary connectors.

Hantek ignition probe with various connection points

Image: Close-up of the Hantek ignition probe, showing its design for signal acquisition.

3. Setup Guide

3.1 Software Installation

  1. Insert the provided software CD into your computer's optical drive.
  2. Follow the on-screen instructions to install the Hantek software and drivers. It is recommended to install drivers before connecting the device.
  3. If your computer does not have an optical drive, download the latest software and drivers from the official Hantek website.
  4. Ensure your operating system's security settings allow for the installation of unsigned drivers if prompted.

3.2 Hardware Connection

  1. Connect the Hantek 1008B unit to your computer using the supplied USB cable.
  2. The operating system should detect the device and complete the driver installation.
  3. Connect the appropriate BNC to alligator clip cables or the ignition probe to the desired input channels on the Hantek 1008B unit.
  4. Ensure all connections are secure before proceeding with measurements.

4. Operating Instructions

The Hantek 1008B offers multiple functionalities accessible through its software interface.

4.1 Automotive Diagnostic Functions

  • Launch the Hantek software.
  • Select the "Vehicle Diagnosis" module from the main interface.
  • Choose the specific diagnostic function required (e.g., Ignition, Sensor, Bus detection).
  • Follow the on-screen prompts and connect the probes to the relevant points on the vehicle.
  • The software will display the waveform and provide diagnostic information.
Hantek software interface showing module selection for Vehicle Diagnosis, Oscilloscope, and Generator

Image: Hantek software main screen, allowing selection between Vehicle Diagnosis, Oscilloscope, and Generator modules.

Hantek software interface showing various primary ignition diagnostic options

Image: Screenshot of the Hantek software displaying various primary ignition diagnostic options, such as voltage, current, and crankshaft sensor analysis.

4.2 Oscilloscope Function

  • Select the "Oscilloscope" module.
  • Configure channel settings (e.g., voltage range, coupling) as needed.
  • Adjust time base and trigger settings to capture the desired waveform.
  • Analyze waveforms for various electrical signals.
Hantek oscilloscope software displaying multiple waveforms

Image: Hantek oscilloscope software interface showing multiple colored waveforms simultaneously, indicating multi-channel measurement capability.

Hantek oscilloscope software displaying a single primary ignition waveform

Image: Screenshot of the Hantek oscilloscope software displaying a single primary ignition waveform, showing detailed signal characteristics.

4.3 Programmable Generator Function

  • Select the "Generator" module.
  • Configure the desired waveform (e.g., square, sine), frequency, and amplitude.
  • Use this function to simulate various signals for testing purposes, such as camshaft and crankshaft signals.

4.4 Data Management

  • Saving Data: The software allows saving waveform data and diagnostic reports. Look for "Save" or "Export" options within the interface.
  • Printing Reports: Diagnostic reports can be printed directly from the software.
  • Screenshots: Utilize the screenshot function to capture specific waveform patterns or diagnostic results.

5. Maintenance

  • Cleaning: Wipe the unit and probes with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the device and its accessories in the provided carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
  • Cable Care: Avoid sharp bends or kinks in the cables to prevent internal damage.
  • Software Updates: Periodically check the official Hantek website for software and driver updates to ensure optimal performance and compatibility.

6. Troubleshooting

ProblemPossible CauseSolution
Device not recognized by computer.Driver not installed or corrupted; USB cable issue.Reinstall drivers from the provided CD or Hantek website. Try a different USB port or cable. Ensure Windows security settings allow driver installation.
No waveform displayed.Incorrect probe connection; incorrect software settings (e.g., voltage range, trigger); no signal input.Verify probe connections. Adjust voltage range and trigger settings. Ensure a valid signal is being applied to the input.
Software crashes or freezes.Outdated software/drivers; system incompatibility; resource conflict.Update software and drivers. Ensure your system meets minimum requirements. Close other demanding applications.
Inaccurate readings.Uncalibrated probes; environmental interference; incorrect settings.Check probe calibration. Minimize electromagnetic interference. Review and correct software settings.

7. Specifications

FeatureDetail
BrandHantek
Model NumberTOL_OCSP_1008B
Channels8
Product Dimensions10.91 x 9.21 x 3.94 inches; 3.1 Pounds
LanguageEnglish
ManufacturerHantek
Date First AvailableApril 30, 2016
UPC889743087734
Detailed specifications table for Hantek 1008B oscilloscope

Image: A table detailing the technical specifications of the Hantek 1008B, including acquisition, input, horizontal, vertical, trigger, and measurement parameters.

8. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your product or visit the official Hantek website. Keep your purchase receipt as proof of purchase for warranty claims.

Hantek Official Website: www.hantek.com

© 2024 Hantek. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.