DERMALOGIC 120

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Dermalogic Towel Steamer 120 Professional User Manual

Model: 120 | Brand: DERMALOGIC

1. Introduction

The Dermalogic Towel Steamer 120 is a professional-grade appliance designed for heating and sanitizing towels in various professional settings such as massage centers, spas, barber shops, and beauty salons. This steamer features a large capacity, adjustable temperature control, and safety features like automatic shut-off and a water refill indicator. Its durable stainless-steel construction ensures longevity and efficient performance.

Dermalogic Towel Steamer 120 front view

Figure 1: Front view of the Dermalogic Towel Steamer 120, showing the control panel and door.

2. Setup

2.1 Unpacking

Carefully remove the steamer from its packaging. Inspect the unit for any signs of damage during transit. Retain all packaging materials for future transport or service needs.

2.2 Placement

  • Place the steamer on a stable, level, and heat-resistant surface.
  • Ensure adequate ventilation around the unit. Do not block air vents.
  • Keep the unit away from water sources or areas where it could be splashed.
  • The unit dimensions are approximately 17 inches (Length) x 17.75 inches (Width) x 26.75 inches (Height). Ensure sufficient space for operation and maintenance.

2.3 Water Filling

  1. Open the steamer door.
  2. Locate the water reservoir at the bottom of the unit.
  3. Fill the reservoir with distilled water only. The reservoir has a capacity of 1.35 gallons. Using tap water or other liquids can lead to mineral buildup and damage the unit.
  4. Do not overfill the reservoir.
  5. Close the steamer door securely.
Dermalogic Towel Steamer 120 interior with shelves

Figure 2: Interior view of the steamer, showing the shelves and water reservoir at the bottom.

2.4 Power Connection

Connect the power cord to a grounded electrical outlet with the correct voltage rating for the unit. Refer to the product label for specific power requirements.

3. Operation

3.1 Loading Towels

  • Open the steamer door.
  • Arrange clean, damp towels on the three internal shelves. Do not overload the shelves, ensuring proper steam circulation.
  • Avoid using towels treated with bleach, softeners, or other chemicals, as these can cause mineral buildup or damage to the unit.
  • Close the steamer door securely.

3.2 Powering On and Temperature Adjustment

  1. Flip the "ON | OFF" switch to the "ON" position. The "POWER" indicator light (red) will illuminate.
  2. Turn the temperature control knob to set the desired temperature. The steamer can heat towels from 90°F to 200°F (32°C to 93°C).
  3. The "HEATING" indicator light (orange) will illuminate when the unit is actively heating. It will cycle on and off as the unit maintains the set temperature.
Dermalogic Towel Steamer 120 control panel close-up

Figure 3: Close-up of the control panel, showing the power switch, indicator lights, and temperature knob.

3.3 Water Refill Indicator and Automatic Shut-off

  • The "WATER LOW" indicator light will illuminate when the water level in the reservoir is low. Refill with distilled water immediately to prevent damage to the heating element.
  • The unit features an automatic shut-off function for safety. If the water level drops too low, the steamer will automatically power off.

3.4 Removing Towels

Use heat-resistant gloves or tongs when removing hot towels from the steamer to avoid burns.

4. Maintenance

4.1 Regular Cleaning

  • Always unplug the unit and allow it to cool completely before cleaning.
  • Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • The interior, including the stainless-steel shelves and walls, should be cleaned regularly to prevent mineral buildup.
  • Remove the shelves and clean them separately with mild soap and water.
  • Wipe down the interior walls and the bottom of the reservoir.

4.2 Preventing Mineral Buildup and Rust

  • Only use distilled water in the reservoir. Tap water contains minerals that will accumulate and can cause rust and damage to the heating element and interior surfaces.
  • Regularly empty and clean the water reservoir to remove any sediment or mineral deposits.
  • Ensure towels are free of chemical residues (e.g., bleach, fabric softeners) before steaming, as these can contribute to corrosion.
Dermalogic Towel Steamer 120 interior shelves for cleaning

Figure 4: Interior of the steamer, highlighting the removable shelves for cleaning.

5. Troubleshooting

ProblemPossible CauseSolution
Unit does not power on.No power supply; Power switch off; Automatic shut-off activated.Check power cord connection and outlet; Ensure power switch is ON; Check water level and refill if low.
Towels are not heating sufficiently.Temperature set too low; Insufficient water; Overloaded unit; Door not closed properly.Adjust temperature setting; Refill water reservoir; Reduce towel load; Ensure door is securely latched.
"WATER LOW" indicator light is on.Water level in reservoir is low.Immediately refill the reservoir with distilled water.
Rust or mineral buildup inside the unit.Use of tap water; Infrequent cleaning.Only use distilled water. Clean the interior regularly as per maintenance instructions.

6. Specifications

  • Model: Dermalogic Towel Steamer 120 (YAN-TSAPP-120)
  • Brand: DERMALOGIC
  • Exterior Dimensions (L x W x H): 17" x 17.75" x 26.75" (43.18 cm x 45.09 cm x 67.95 cm)
  • Interior Dimensions (L x W x H): 14.5" x 13" x 20.5" (36.83 cm x 33.02 cm x 52.07 cm)
  • Parcel Dimensions (L x W x H): 74.93 cm x 53.34 cm x 50.8 cm (29.5" x 21" x 20")
  • Weight: 21.55 kg (47.5 lbs)
  • Water Reservoir Capacity: 1.35 gallons (approximately 5.1 liters)
  • Temperature Range: 90°F - 200°F (32°C - 93°C)
  • Construction Material: Durable Stainless Steel
  • Safety Features: Automatic Shut-off, Water Refill Indicator Light
  • Shelves: 3 internal shelves

7. Warranty & Support

7.1 Warranty Information

Specific warranty details for the Dermalogic Towel Steamer 120 are not provided in the product information. Please contact your retailer or the manufacturer directly for any warranty-related inquiries.

7.2 Customer Support

For technical assistance, parts, or service, please contact the retailer where the product was purchased or visit the official DERMALOGIC website for contact information.

© 2023 DERMALOGIC. All rights reserved. Information subject to change without notice.