Aspen Ax3006/1

Aspen AX3006/1 Mobile Air Conditioner User Manual

Model: AX3006/1

1. Introduction

Thank you for choosing the Aspen AX3006/1 Mobile Air Conditioner. This versatile unit is designed to provide efficient cooling, dehumidification, and ventilation for rooms up to 40m². Please read this manual thoroughly before operating your new appliance to ensure safe and optimal performance. Keep this manual for future reference.

2. Safety Instructions

Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

3. Product Overview

The Aspen AX3006/1 is a compact and efficient mobile air conditioner. Below is an image of the unit, highlighting its general appearance.

Aspen AX3006/1 Mobile Air Conditioner, front-side view

Figure 3.1: Front-side view of the Aspen AX3006/1 Mobile Air Conditioner. The unit is white with black accents, featuring a control panel on top and an exhaust port on the side.

Key Features:

4. Setup Guide

4.1 Unpacking

  1. Carefully remove the air conditioner and all accessories from the packaging.
  2. Check for any damage during transit. If damaged, do not operate the unit and contact your retailer.
  3. Keep the original packaging for future storage or transport.

4.2 Exhaust Hose Installation

  1. Locate the exhaust hose and its connectors.
  2. Screw one end of the exhaust hose onto the air outlet on the back of the unit.
  3. Attach the window kit adapter to the other end of the exhaust hose.

4.3 Window Kit Installation

  1. Open the window or sliding door where you intend to vent the hot air.
  2. Place the adjustable window sealing plate into the window opening. Adjust its length to fit snugly.
  3. Insert the window kit adapter (attached to the exhaust hose) into the opening of the window sealing plate.
  4. Ensure the window is closed as much as possible around the sealing plate to minimize air leakage.

5. Operating Instructions

5.1 Control Panel

The control panel is located on the top of the unit. It typically includes buttons for Power, Mode, Fan Speed, Temperature Up/Down, and a display screen.

5.2 Operating Modes

5.3 Temperature and Fan Speed Adjustment

6. Maintenance

Regular maintenance ensures the longevity and efficiency of your air conditioner. Always unplug the unit before performing any maintenance.

6.1 Cleaning the Air Filter

  1. Locate the air filter, usually at the back or side of the unit.
  2. Gently remove the filter.
  3. Clean the filter with a vacuum cleaner or wash it with lukewarm water and mild detergent.
  4. Rinse thoroughly and allow it to air dry completely before reinserting.
  5. Clean the filter every two weeks or more frequently if the unit is used often or in dusty environments.

6.2 Draining Water

The unit collects condensed water during operation. Depending on the model, it may have a self-evaporating system or require manual draining.

6.3 Storage

  1. Before storing, ensure all water is drained from the unit.
  2. Clean the air filter and allow it to dry.
  3. Unplug the power cord and coil it neatly.
  4. Store the unit in a dry, cool place, preferably in its original packaging, away from direct sunlight and extreme temperatures.

7. Troubleshooting

Before contacting customer support, please refer to the following table for common issues and their solutions.

ProblemPossible CauseSolution
Unit does not turn on.No power, power cord not plugged in, circuit breaker tripped.Check power outlet, ensure cord is securely plugged in, reset circuit breaker.
Unit does not cool effectively.Air filter dirty, exhaust hose not properly installed, room too large, windows/doors open.Clean air filter, ensure exhaust hose is sealed, close windows/doors, check room size.
Unit is noisy.Unit not on a flat surface, fan obstruction.Place unit on a flat, stable surface. Check for obstructions in fan area.
Water leakage.Drain plug loose, continuous drain hose not properly connected.Ensure drain plug is secure. Check continuous drain hose connection.

8. Technical Specifications

SpecificationValue
BrandAspen
Model NumberAX3006/1
Product Dimensions400 x 400 x 400 cm
Cooling Capacity3.5 kW
Voltage230 Volt
Power SourceCorded Electric
Special FeaturesDehumidifier
Form FactorPortable

9. Warranty and Customer Support

This Aspen AX3006/1 Mobile Air Conditioner comes with a limited warranty. Please refer to the warranty card included in your product packaging for specific terms and conditions, including the warranty period and coverage details.

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your retailer or the manufacturer's customer support. Contact information can typically be found on the product packaging or the manufacturer's official website.

Note: Always have your model number (AX3006/1) and purchase date ready when contacting support.

Related Documents - Ax3006/1

Preview ASPEN 03 Sideboard Assembly Instructions
Comprehensive assembly guide for the ASPEN 03 sideboard, detailing parts, accessories, and step-by-step instructions for building the furniture. Includes safety information regarding wall mounting.
Preview ASPEN 09 OP-317 Bathroom Cabinet Assembly Instructions
Comprehensive assembly guide for the ASPEN 09 OP-317 bathroom vanity unit. Includes parts list, safety precautions, and step-by-step instructions with diagrams described in text.
Preview Universal Aspen Air Handler Nomenclature Guide
A guide to understanding the nomenclature for Universal Aspen Air Handlers, detailing model configurations, voltage, tonnage, coil size, metering devices, and option codes.
Preview Aspen Vista Cervical Collar Patient Handbook and Guide
This patient handbook provides essential information for using the Aspen Vista Cervical Collar, including instructions on motion restriction, skin care, pad replacement and cleaning, at-home care, and fitting guidelines. It also details different types of cervical collars and nursing procedures for their care.
Preview Aspen AAM Series Electric Multi-Position Air Handler - Technical Specifications & Data
Explore the Aspen AAM Series electric multi-position air handlers featuring copper coils. This document provides detailed performance data, electrical specifications, dimensions, and nomenclature for R22, R410A, R454B, and R32 refrigerant systems.
Preview Aspen Dual A2L Refrigerant Detection Systems (RDS) Kits for R32 & R454B
Aspen's Dual A2L Refrigerant Detection Systems (RDS) kits for R32 and R454B refrigerants offer advanced safety features, UL 60335-2-40 compliance, and flexible installation for HVAC systems.