1. Introduction
Thank you for choosing the Aspen AX3006/1 Mobile Air Conditioner. This versatile unit is designed to provide efficient cooling, dehumidification, and ventilation for rooms up to 40m². Please read this manual thoroughly before operating your new appliance to ensure safe and optimal performance. Keep this manual for future reference.
2. Safety Instructions
Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
- Electrical Safety: Ensure the power supply matches the voltage specified on the rating label. Do not use extension cords or multi-sockets. Always plug the unit into a grounded outlet.
- Placement: Place the unit on a flat, stable surface. Maintain at least 30cm clearance from walls and other objects to ensure proper airflow. Do not block air inlets or outlets.
- Operation: Do not operate the unit with wet hands. Do not insert objects into the air outlets. Unplug the unit before cleaning or maintenance.
- Children and Pets: Keep children and pets away from the unit during operation. This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities unless supervised.
- Maintenance: Only perform maintenance as described in this manual. For repairs, contact qualified service personnel.
- Storage: When not in use for extended periods, drain all water, clean the filters, and store the unit in a dry, cool place.
3. Product Overview
The Aspen AX3006/1 is a compact and efficient mobile air conditioner. Below is an image of the unit, highlighting its general appearance.

Figure 3.1: Front-side view of the Aspen AX3006/1 Mobile Air Conditioner. The unit is white with black accents, featuring a control panel on top and an exhaust port on the side.
Key Features:
- Mobile air conditioner with exhaust hose.
- Suitable for private use in rooms up to 40m².
- Selectable operating modes: Cooling, Dehumidification, Ventilation.
- Cooling capacity: 3.5 kW.
- Portable form factor.
4. Setup Guide
4.1 Unpacking
- Carefully remove the air conditioner and all accessories from the packaging.
- Check for any damage during transit. If damaged, do not operate the unit and contact your retailer.
- Keep the original packaging for future storage or transport.
4.2 Exhaust Hose Installation
- Locate the exhaust hose and its connectors.
- Screw one end of the exhaust hose onto the air outlet on the back of the unit.
- Attach the window kit adapter to the other end of the exhaust hose.
4.3 Window Kit Installation
- Open the window or sliding door where you intend to vent the hot air.
- Place the adjustable window sealing plate into the window opening. Adjust its length to fit snugly.
- Insert the window kit adapter (attached to the exhaust hose) into the opening of the window sealing plate.
- Ensure the window is closed as much as possible around the sealing plate to minimize air leakage.
5. Operating Instructions
5.1 Control Panel
The control panel is located on the top of the unit. It typically includes buttons for Power, Mode, Fan Speed, Temperature Up/Down, and a display screen.
5.2 Operating Modes
- Cooling Mode: Press the "Mode" button until the cooling indicator light illuminates. Use the temperature adjustment buttons to set your desired room temperature. The unit will cool the room to the set temperature.
- Dehumidification Mode: Press the "Mode" button until the dehumidification indicator light illuminates. In this mode, the unit removes moisture from the air without significant cooling. The fan speed is typically fixed.
- Fan Mode (Ventilation): Press the "Mode" button until the fan indicator light illuminates. The unit will circulate air without cooling or dehumidifying. You can adjust the fan speed in this mode.
5.3 Temperature and Fan Speed Adjustment
- Temperature: In Cooling mode, use the "Up" and "Down" arrows to set the desired temperature. The adjustable range is typically between 16°C and 32°C.
- Fan Speed: In Cooling or Fan mode, press the "Fan Speed" button to cycle through available fan speeds (e.g., Low, Medium, High).
6. Maintenance
Regular maintenance ensures the longevity and efficiency of your air conditioner. Always unplug the unit before performing any maintenance.
6.1 Cleaning the Air Filter
- Locate the air filter, usually at the back or side of the unit.
- Gently remove the filter.
- Clean the filter with a vacuum cleaner or wash it with lukewarm water and mild detergent.
- Rinse thoroughly and allow it to air dry completely before reinserting.
- Clean the filter every two weeks or more frequently if the unit is used often or in dusty environments.
6.2 Draining Water
The unit collects condensed water during operation. Depending on the model, it may have a self-evaporating system or require manual draining.
- Continuous Draining (if applicable): Connect a drain hose (not included) to the continuous drain port and lead it to a floor drain or bucket.
- Manual Draining: When the internal water tank is full, the unit may stop operating and display an error code. Place a shallow pan or tray under the drain port at the bottom of the unit. Remove the drain plug and allow all water to drain out. Replace the plug securely.
6.3 Storage
- Before storing, ensure all water is drained from the unit.
- Clean the air filter and allow it to dry.
- Unplug the power cord and coil it neatly.
- Store the unit in a dry, cool place, preferably in its original packaging, away from direct sunlight and extreme temperatures.
7. Troubleshooting
Before contacting customer support, please refer to the following table for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, power cord not plugged in, circuit breaker tripped. | Check power outlet, ensure cord is securely plugged in, reset circuit breaker. |
| Unit does not cool effectively. | Air filter dirty, exhaust hose not properly installed, room too large, windows/doors open. | Clean air filter, ensure exhaust hose is sealed, close windows/doors, check room size. |
| Unit is noisy. | Unit not on a flat surface, fan obstruction. | Place unit on a flat, stable surface. Check for obstructions in fan area. |
| Water leakage. | Drain plug loose, continuous drain hose not properly connected. | Ensure drain plug is secure. Check continuous drain hose connection. |
8. Technical Specifications
| Specification | Value |
|---|---|
| Brand | Aspen |
| Model Number | AX3006/1 |
| Product Dimensions | 400 x 400 x 400 cm |
| Cooling Capacity | 3.5 kW |
| Voltage | 230 Volt |
| Power Source | Corded Electric |
| Special Features | Dehumidifier |
| Form Factor | Portable |
9. Warranty and Customer Support
This Aspen AX3006/1 Mobile Air Conditioner comes with a limited warranty. Please refer to the warranty card included in your product packaging for specific terms and conditions, including the warranty period and coverage details.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your retailer or the manufacturer's customer support. Contact information can typically be found on the product packaging or the manufacturer's official website.
Note: Always have your model number (AX3006/1) and purchase date ready when contacting support.