NOYAFA NF-178

Noyafa NF-178 GPS Land Measuring Instrument: User Manual

Model: NF-178 | Brand: NOYAFA

1. Introduction

The Noyafa NF-178 is a versatile GPS land measuring instrument designed for accurate area and distance calculations. It features a 2.8-inch display and supports both manual and automatic measurement methods, making it suitable for various outdoor land surveying tasks.

Noyafa NF-178 GPS Land Measuring Instrument

Figure 1: Noyafa NF-178 GPS Land Measuring Instrument. This image displays the device with its screen showing GPS coordinates and date, set against a background of fields and mountains, indicating its outdoor use.

Key Features:

2. Safety Precautions and Important Notes

To ensure accurate measurements and safe operation, please observe the following guidelines:

3. Product Overview

Familiarize yourself with the components and controls of your Noyafa NF-178 instrument.

Noyafa NF-178 Product Components

Figure 2: Labeled components of the Noyafa NF-178. This diagram highlights the LCD screen, signal strength indicator, backlight button, LED light, length button, up/down navigation, OK/Enter button, Save button, Power button, Back button, charging port, and laser.

Component Identification:

4. Setup

4.1. Battery Installation and Charging

The Noyafa NF-178 comes with a pre-installed 3.7V/1000mAh lithium battery. Ensure the battery is properly seated before first use.

Noyafa NF-178 Battery and Charging

Figure 3: Battery compartment and USB charging port. This image illustrates the internal 3.7V/1000mAh lithium battery and the common USB charging port, highlighting the device's power solution.

4.2. Initial Power On

Press and hold the Power button until the screen illuminates. The device will perform a self-check and attempt to acquire GPS satellite signals.

5. Operating Instructions

5.1. Manual Area Measurement

Follow these steps for manual area measurement:

  1. Acquire Satellites: Ensure the device has acquired at least 6 satellite signals. The signal strength indicator on the screen will confirm this.
  2. Enter Manual Testing Mode:
    • Navigate to the "Set" menu.
    • Select "Manual Testing".
    • Return to the main menu.
  3. Start Area Measurement: From the main menu, select "Area" to begin.
  4. Mark Points:
    • Walk along the perimeter of the land you wish to measure.
    • Press the Save button at each corner or significant point (e.g., A, B, C, D).
    • The device will record the GPS coordinates for each point.
  5. Complete Measurement: After marking all points, return to the starting point (Point A). Press the OK button to finalize the measurement.
  6. View Results: The calculated area and length will be displayed on the screen.
  7. Save Data: Press the Save button to store the measurement data.
Noyafa NF-178 Manual Testing Steps

Figure 4: Manual testing procedure. This graphic illustrates the four steps for manual area measurement: satellite acquisition, entering manual testing mode, marking points (A, B, C, D), and viewing the final area and length results on the device screen.

The land graph can also be checked later from the saved data.

5.2. Distance Measurement

To measure the distance between two points:

  1. From the main menu, select "Length".
  2. Walk from the starting point to the end point.
  3. The device will continuously display the distance covered.
  4. Press Save to record the final distance.

5.3. System Settings

To customize device settings:

  1. Navigate to the "Set" menu.
  2. Use the Up/Down buttons to select options such as:
    • Area Unit Set: Choose between mu, square, hectare, etc.
    • Length Unit Set: Choose between kilometers, meters, etc.
    • Area Unit Price Set: (If applicable) Set a price per unit of area for automatic calculation.
  3. Press Enter/OK to confirm your selection.
  4. Use the Up/Down buttons to adjust the value, then press Enter/OK to save.
Noyafa NF-178 System Settings

Figure 5: System settings interface. This image shows examples of the "Area unit set" and "Area unit price set" screens, demonstrating how users can customize measurement units and pricing within the device's settings.

5.4. Data Management

6. Maintenance

7. Troubleshooting

8. Specifications

FeatureDetail
BrandNOYAFA
Model NumberNF-178
ManufacturerNoyafa
Item Weight386 g
Package Dimensions21.6 x 13.8 x 4.6 cm
Batteries1 AAA battery required (included), Lithium battery (3.7V/1000mAh)
Power SourceBattery Powered
Included ComponentsPCB, Instrument, USB Cable, User Manual, Carrying Pouch
Display2.8 inch 320 x 240
Measurement Unitsmu, square, hectare, kilometers
Noyafa NF-178 Packing List

Figure 6: Contents of the Noyafa NF-178 package. This image shows the retail box, the NF-178 device, a user manual, and a protective carrying pouch, indicating the items included with the product.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact Noyafa customer service directly. Contact details are typically available on the manufacturer's official website.

Related Documents - NF-178

Preview NOYAFA NF-198 GPS Land Meter User Manual
Comprehensive user manual for the NOYAFA NF-198 GPS Land Meter, detailing its features, operation, specifications, and troubleshooting for accurate land area measurement.
Preview Noyafa NF-271 & NF-272L Laser Distance Meter Instruction Manual
Comprehensive instruction manual for Noyafa NF-271 and NF-272L Laser Distance Meters, covering features, operation, specifications, and troubleshooting.
Preview Noyafa NF-271, NF-272L, NF-275L Laser Distance Meter Instruction Manual
Comprehensive instruction manual for Noyafa laser distance meters, covering models NF-271, NF-272L, and NF-275L. Details product features, operation instructions, specifications, and troubleshooting.
Preview NOYAFA NF-2030/NF-2050 Laser Distance Meter Instruction Manual
This instruction manual provides detailed guidance on operating the NOYAFA NF-2030 and NF-2050 laser distance meters, including features, specifications, and troubleshooting tips.
Preview NOYAFA NF-271, NF-272L, NF-275L Laser Distance Meter Instruction Manual
Comprehensive instruction manual for NOYAFA NF-271, NF-272L, and NF-275L laser distance meters. Covers features, operation, specifications, and troubleshooting for accurate distance measurement.
Preview NOYAFA Laser Distance Meter Instruction Manual (NF-271, NF-272L, NF-275L)
Comprehensive instruction manual for NOYAFA laser distance meters, including models NF-271, NF-272L, and NF-275L. Covers features, operation, specifications, and troubleshooting.