Cisa 82750

CISA DGT Vision Electronic Safe 82750 Instruction Manual

Model: 82750 | Brand: CISA

Introduction

This manual provides essential instructions for the installation, operation, and maintenance of your CISA DGT Vision Electronic Safe, model 82750. Please read this manual thoroughly before using the safe to ensure proper function and security.

Safety Information

Package Contents

CISA DGT Vision Electronic Safe packaging box

Image: The CISA DGT Vision Electronic Safe as it appears in its packaging box, secured with white straps.

Setup and Installation

The CISA DGT Vision safe is designed for secure installation within furniture or anchored to a wall/floor. Proper installation is crucial for security.

Choosing an Installation Location

Anchoring the Safe

The safe features pre-drilled holes for anchoring.

  1. Position the safe in the desired location.
  2. Mark the drilling points through the pre-drilled holes on the back or bottom of the safe onto the mounting surface.
  3. Move the safe and drill appropriate holes in the marked positions.
  4. Insert suitable anchors (not always included, check package contents) into the drilled holes.
  5. Reposition the safe and secure it using the provided or appropriate screws. Tighten all screws firmly.
Interior view of the CISA DGT Vision Electronic Safe showing pre-drilled mounting holes

Image: Interior view of the CISA DGT Vision Electronic Safe, showing the pre-drilled holes on the back and bottom for secure mounting.

Diagram showing dimensions of the CISA DGT Vision Electronic Safe

Image: Technical diagram illustrating the external dimensions of the CISA DGT Vision Electronic Safe: 420mm (width) x 300mm (height) x 350mm (depth).

Operating Instructions

Initial Battery Installation

The electronic keypad requires 1.5V alkaline button cell batteries.

  1. Locate the battery compartment, typically on the inside of the safe door.
  2. Insert the batteries, ensuring correct polarity.
  3. Close the battery compartment cover.
Close-up of the CISA DGT Vision electronic keypad

Image: A detailed view of the CISA DGT Vision electronic keypad, featuring numerical buttons and function keys.

Opening the Safe for the First Time

Upon initial setup, the safe typically has a factory-set default code (e.g., "1234" or "0000"). Refer to the specific instructions provided with your safe for the exact default code.

  1. Enter the default code on the keypad.
  2. Press the confirmation button (often marked with a key or checkmark symbol).
  3. The lock will disengage, and you can open the door.
Hand interacting with the CISA DGT Vision electronic keypad

Image: A hand pressing buttons on the CISA DGT Vision electronic keypad, demonstrating user interaction.

Setting/Changing Your Personal Code

It is highly recommended to change the default code immediately after the first opening.

  1. With the safe door open, locate the internal reset button (often a small button on the inside of the door or near the battery compartment).
  2. Press the reset button. The keypad will usually emit a beep or light up to indicate it's ready for a new code.
  3. Enter your new personal code (typically 4-8 digits).
  4. Press the confirmation button.
  5. Re-enter your new personal code and press the confirmation button again to confirm.
  6. Test the new code with the door open before closing it.

Closing and Locking the Safe

To lock the safe, simply close the door. The locking bolts will automatically engage.

Close-up of the CISA DGT Vision safe's locking bolts

Image: A close-up view of the robust nickel-plated steel locking bolts of the CISA DGT Vision safe, extended from the door edge.

Maintenance

Battery Replacement

The keypad features indicator lights to warn of low battery power. Replace batteries promptly when this warning appears to avoid being locked out.

  1. Open the safe using your code.
  2. Locate the battery compartment on the inside of the door.
  3. Remove the old batteries and dispose of them responsibly.
  4. Insert new 1.5V alkaline button cell batteries, observing correct polarity.
  5. Close the battery compartment.

External Emergency Power

If batteries completely drain and you cannot open the safe, use the external emergency power cable.

  1. Locate the external power input port on the keypad (often a small socket).
  2. Connect the emergency power cable to this port and to a fresh 9V battery (not included).
  3. While holding the emergency power, enter your code to open the safe.
  4. Replace the internal batteries immediately after opening.

General Care

Troubleshooting

Safe Does Not Open with Code

Keypad Does Not Respond

Safe Door Does Not Close Properly

Specifications

FeatureDetail
Model82750
BrandCISA
Dimensions (L x H x P)420 mm x 300 mm x 350 mm
Weight17.55 kg (38.7 lbs)
MaterialAlloy Steel
Lock TypeElectronic Keypad
Power Source1.5V Alkaline Button Cell Batteries (internal), 9V Battery (external emergency)
ColorAnthracite

Warranty and Support

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact CISA customer service directly. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official CISA website or contact their authorized service centers.

Related Documents - 82750

Preview CISA Mito Sensor: Installation and User Manual
Comprehensive guide for the CISA Mito Sensor lock, detailing installation, operation, maintenance, safety, and troubleshooting. Includes technical specifications and accessories.
Preview CISA Push Microswitch Installation Guide - Model 06A95060
Official installation instructions for the CISA Push Microswitch (Model 06A95060), a component for panic exit devices. Includes steps for securing to bracket and checking operation.
Preview CISA Touch Microswitch Installation Guide
Official installation instructions for the CISA Touch Microswitch (Art. 06A95050), detailing arm bracket dismantling, microswitch assembly, and operational checks.
Preview Guida all'Installazione CISA: Comandi Esterni per Maniglioni Antipanico (Art. 07A78.xx)
Istruzioni dettagliate per l'installazione dei comandi esterni CISA per maniglioni antipanico, modello Art. 07A78.xx. Include configurazioni, montaggio e specifiche tecniche.
Preview CISA Electric Strikes Cover Installation Guide
Instruction sheet for CISA electric strikes covers (Art. 06A98120.XX), detailing installation configurations and mounting procedures for various door edge types. Includes guidance on selecting appropriate plates and screws.
Preview CISA 06A98910 Adapter for Fast Access Devices Retrofit - Installation Guide
This document provides installation instructions for the CISA 06A98910 Adapter for Fast Access Devices Retrofit. It covers assembly, cutting specifications, and final checks for various door configurations.