WARNING: Read and understand all instructions before installing or operating this pump. Failure to follow these instructions can result in electric shock, fire, serious injury, or death.

  • Always disconnect the pump from the power source before performing any maintenance or service.
  • Ensure the electrical circuit is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI).
  • Do not operate the pump with a damaged cord or plug.
  • Do not use this pump for flammable or corrosive liquids.
  • Wear appropriate personal protective equipment (PPE) such as safety glasses and gloves during installation and maintenance.
  • Keep children and pets away from the pump and sump pit area.

This pump is designed for pumping clear water only. Do not use it for sewage, saltwater, or other hazardous liquids.

2. Product Overview

The BurCam 039-300500 is a robust submersible sump pump designed for efficient water removal from basements, crawl spaces, and other areas prone to flooding. It features a durable construction and an integrated float switch for automatic operation.

BurCam 039-300500 Submersible Sump Pump with float switch

Figure 1: BurCam 039-300500 Submersible Sump Pump. This image shows the pump unit with its discharge port and the attached hardwired float switch.

Key Features:

  • Noryl Float Switch: Provides reliable automatic on/off operation.
  • 1/3 HP Motor: Delivers efficient pumping power.
  • Oil Cooled Motor: Ensures long-term performance and durability.
  • Non-Corrosive Material: Constructed from materials resistant to rust and corrosion.
  • Thermal and Overload Protection: Safeguards the motor from overheating.
  • Maximum Flow Rate: Up to 3000 Gallons Per Hour (50 GPM).

3. Setup and Installation

3.1 Pre-Installation Checklist:

  • Ensure the sump pit is clean and free of debris.
  • Verify that the power supply is 115V AC and protected by a GFCI outlet.
  • Gather necessary tools: pipe wrench, screwdriver, thread sealant tape.

3.2 Placement:

Place the pump on a solid, level surface at the bottom of the sump pit. Ensure the pump is not resting directly on dirt or gravel, which could clog the intake. Use bricks or a solid base if necessary.

3.3 Discharge Pipe Connection:

  1. Connect a 1.5-inch discharge pipe to the pump's discharge port. The pump includes a 1.25-inch reducer if a smaller pipe is required.
  2. Use thread sealant tape on all threaded connections to prevent leaks.
  3. Install a check valve in the discharge line above the pump to prevent water from flowing back into the sump pit when the pump shuts off.
  4. Route the discharge pipe to an appropriate drainage area, ensuring it is sloped away from the foundation.

3.4 Float Switch Adjustment:

The hardwired float switch is pre-set for optimal operation. Ensure the float can move freely without obstruction within the sump pit. The "on" level should be high enough to prevent frequent cycling, and the "off" level should be low enough to adequately drain the pit without running dry for extended periods.

3.5 Electrical Connection:

Plug the pump's power cord into a dedicated 115V AC, GFCI-protected electrical outlet. Do not use extension cords. Ensure the outlet is located in a dry area and is easily accessible.

4. Operating Instructions

4.1 Automatic Operation:

Once properly installed and connected to power, the BurCam 039-300500 sump pump will operate automatically. The pump will turn on when the water level rises and lifts the float switch to its "on" position. It will continue to pump water until the water level drops, allowing the float switch to return to its "off" position.

4.2 Manual Test:

To test the pump's operation:

  1. Ensure the pump is plugged in.
  2. Fill the sump pit with water until the float switch rises and activates the pump.
  3. Observe the pump operating and discharging water.
  4. Allow the pump to run until the water level drops and the float switch deactivates the pump.
  5. If the pump does not activate or deactivate as expected, refer to the Troubleshooting section.

5. Maintenance

Regular maintenance ensures optimal performance and extends the life of your sump pump. Always disconnect power before performing any maintenance.

5.1 Monthly Inspection:

  • Sump Pit: Remove any debris, dirt, or sediment from the sump pit that could obstruct the pump intake or float switch.
  • Float Switch: Ensure the float switch moves freely and is not obstructed by wires, pipes, or debris.
  • Discharge Pipe: Check the discharge pipe for any leaks or blockages.
  • Test Operation: Perform a manual test as described in Section 4.2.

5.2 Annual Cleaning:

  • Disconnect the pump from power and remove it from the sump pit.
  • Rinse the pump housing and intake screen with clean water to remove any accumulated sludge or debris.
  • Inspect the power cord for any signs of damage or wear.
  • Reinstall the pump and perform a manual test.

5.3 Winterization (if applicable):

If the pump is installed in an area subject to freezing temperatures and will not be used, it should be removed, cleaned, and stored in a warm, dry location to prevent damage from freezing water.

6. Troubleshooting

Before troubleshooting, always disconnect the pump from the power source.

Problem Possible Cause Solution
Pump does not run.
  • No power to the pump.
  • Float switch obstructed or defective.
  • Motor thermal overload tripped.
  • Check power supply, GFCI, and circuit breaker.
  • Clear obstructions around the float switch. Replace if defective.
  • Allow pump to cool down. It should reset automatically.
Pump runs but does not pump water.
  • Intake screen clogged.
  • Discharge pipe blocked or frozen.
  • Air lock in the pump.
  • Impeller damaged.
  • Clean intake screen.
  • Clear blockage in discharge pipe.
  • Lift and lower the pump several times to release trapped air.
  • Contact customer support for impeller replacement.
Pump runs continuously.
  • Float switch obstructed in "on" position.
  • Check valve leaking or missing.
  • Pump undersized for inflow.
  • Clear obstructions around the float switch.
  • Inspect and replace check valve if necessary.
  • Consult a professional to assess pump capacity.

7. Specifications

Parameter Value
Model Number 039-300500
Brand BurCam
Horsepower (HP) 1/3 hp
Voltage 115V AC
Maximum Flow Rate 3000 GPH (50 GPM)
Discharge Size 1.5 inches (with 1.25 inch reducer)
Float Switch Type Hardwired Noryl Float
Motor Cooling Oil Cooled
Material Non-corrosive
Protection Thermal and Overload Protection
Product Weight 11 lbs

8. Warranty and Customer Support

For warranty information or technical assistance, please contact BurCam customer support. Keep your purchase receipt as proof of purchase.

Contact details can typically be found on the product packaging or the manufacturer's official website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.