Supra VERCORS3

Supra VERCORS 3 Wood-Burning Stove Instruction Manual

Model: VERCORS 3 | Brand: Supra

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Supra VERCORS 3 wood-burning stove. Please read all instructions carefully before attempting to install or use the appliance. Proper installation and maintenance are crucial for optimal performance and safety.

Supra VERCORS 3 Wood-Burning Stove, front view with fire burning

Figure 1: Front view of the Supra VERCORS 3 wood-burning stove in operation. This image shows the stove's design, including the glass door revealing the burning wood, and the top flue connection.

2. Safety Information

Your safety is paramount. Failure to follow these safety guidelines can result in property damage, serious injury, or death. Always adhere to local and national building and fire codes.

  • Professional Installation: Installation must be performed by a qualified professional in accordance with all applicable local and national building and fire codes.
  • Ventilation: Ensure adequate ventilation in the room where the stove is installed to prevent carbon monoxide buildup.
  • Clearances: Maintain required clearances from combustible materials (walls, furniture, curtains, etc.) as specified in the installation instructions.
  • Fuel Type: Use only dry, seasoned hardwood as fuel. Never burn treated wood, trash, plastics, or flammable liquids.
  • Supervision: Never leave the stove unattended while in operation.
  • Children and Pets: Keep children and pets away from the hot surfaces of the stove. The stove's exterior can reach very high temperatures.
  • Fire Extinguisher: Keep a fire extinguisher readily accessible.
  • Carbon Monoxide Detector: Install and regularly check a carbon monoxide detector in the vicinity of the stove.

3. Setup and Installation

The Supra VERCORS 3 wood-burning stove requires careful installation to ensure safe and efficient operation. It is highly recommended that installation be carried out by a certified professional.

3.1 Site Preparation

  • Hearth: The stove must be placed on a non-combustible hearth that extends beyond the stove's footprint according to local regulations.
  • Structural Support: The stove weighs approximately 205 kg (451.95 lbs). Ensure the floor structure can safely support this weight.
  • Dimensions: Consider the stove's dimensions (72 cm width x 44.5 cm depth x 81.5 cm height) when planning placement.

3.2 Chimney and Flue Connection

  • Chimney System: Connect the stove to a suitable, properly sized, and maintained chimney system.
  • Exhaust Diameter: The stove requires a 15 cm (approximately 5.9 inches) diameter exhaust connection.
  • Flue Pipe: Use appropriate flue pipes and connectors, ensuring all joints are sealed and secure.
Supra VERCORS 3 Wood-Burning Stove installed in a living room

Figure 2: The Supra VERCORS 3 wood-burning stove installed in a room, demonstrating its typical placement and connection to a vertical flue pipe. This image provides context for installation within a home environment.

4. Operating Instructions

Follow these steps for safe and efficient operation of your wood-burning stove.

4.1 Fueling the Stove

  • Recommended Fuel: Use only dry, seasoned hardwood. Wood should be split and seasoned for at least 6-12 months.
  • Loading: Open the stove door slowly to prevent smoke spillage. Place a small amount of crumpled newspaper or firelighters, followed by small kindling, then progressively larger pieces of wood. Do not overfill the firebox.

4.2 Starting a Fire

  1. Ensure all air intake vents are fully open.
  2. Ignite the newspaper/firelighters.
  3. Leave the stove door slightly ajar for a few minutes to establish a strong draft, then close it securely.
  4. Once the fire is burning steadily, gradually add larger pieces of wood.

4.3 Controlling the Burn

  • Air Intake: Adjust the air intake controls to regulate the burn rate and heat output. Closing the air intake will slow the burn; opening it will increase it.
  • Optimal Burn: Aim for a steady, bright flame. Excessive smoke indicates an inefficient burn or wet wood.

5. Maintenance

Regular maintenance ensures the longevity and safe operation of your Supra VERCORS 3 stove.

  • Ash Removal: Regularly remove ash from the ash pan. Do not allow ash to build up to the level of the grate, as this can restrict airflow and damage the grate. Dispose of hot ashes in a metal container with a tight-fitting lid, away from combustible materials.
  • Chimney Cleaning: The chimney and flue pipe should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard.
  • Glass Cleaning: Clean the stove glass with a specialized glass cleaner designed for wood stoves when the stove is completely cool. Avoid abrasive cleaners.
  • Door Gasket: Inspect the door gasket periodically for wear and tear. A worn gasket can lead to air leaks and reduced efficiency. Replace if necessary.
  • General Inspection: Annually inspect the stove for any signs of damage, cracks, or loose components.

6. Troubleshooting

This section addresses common issues you might encounter with your wood-burning stove.

6.1 Smoke Entering the Room

  • Cause: Insufficient draft, blocked chimney, or opening the door too quickly.
  • Solution: Ensure chimney is clear of obstructions. Check that air vents are open. Open the stove door slowly. Consider pre-heating the flue if the stove is cold.

6.2 Poor Burn or Low Heat Output

  • Cause: Wet wood, insufficient air supply, or chimney issues.
  • Solution: Use only dry, seasoned wood. Ensure air intake vents are fully open. Check for creosote buildup in the chimney.

6.3 Excessive Creosote Buildup

  • Cause: Burning wet wood, restricted air supply, or low burning temperatures.
  • Solution: Burn only dry wood. Ensure adequate air supply for a hot, clean burn. Have the chimney cleaned regularly.

7. Specifications

FeatureSpecification
BrandSupra
Model NumberVERCORS3
ColorBlack
Dimensions (W x D x H)72 cm x 44.5 cm x 81.5 cm (28.3 x 17.5 x 32.1 inches)
Weight205 kg (451.95 lbs)
Heat Output10000 W (10 kW)
Efficiency76%
Suitable Room VolumeUp to 150 m³
Fuel TypeWood
Exhaust Connection Diameter15 cm (5.9 inches)
MaterialDurable construction, typically cast iron or steel.

8. Warranty and Support

For warranty details, technical support, or replacement parts, please refer to the documentation provided at the time of purchase. You may also contact Supra customer service directly through their official website or authorized distributors.

Keep your purchase receipt and model number (VERCORS3) readily available when contacting support.

Related Documents - VERCORS3

Preview Supra USKO Wood Burning Stove: Installation and User Manual
Comprehensive guide for installing, using, and maintaining the Supra USKO wood burning stove. Includes technical specifications, safety guidelines, operational instructions, and maintenance recommendations.
Preview Supra PERSEE Wood Stove: Installation, Use, and Maintenance Guide
Comprehensive guide for the Supra PERSEE wood stove, covering technical characteristics, installation, operation, maintenance, and safety instructions. Includes model variations like PERSEE SUR PIED and PERSEE SUR BÜCHER.
Preview X96 AIR DVB-T2 TV Box User Manual
User manual for the X96 AIR DVB-T2 TV Box, covering setup, features, and operation. Includes model information for SUPRA TELEBOX and SKY VISION.
Preview Supra Berenice Heated Towel Rail User Manual
Detailed user manual and instructions for the Supra Berenice heated towel rail, covering installation, operation, safety, and maintenance. Learn how to use your Supra Berenice effectively and safely.
Preview Supra Bluetooth iBox Keyboxes: User Guide for Secure Access
This user guide provides essential information on the Supra Bluetooth iBox LE and iBox BT electronic keyboxes, covering their features, operation, maintenance, and regulatory compliance.
Preview SUPRA LoRad MD02EU-MD06EU: High-Performance Shielded Power Strip with NIF Filter
Discover the SUPRA LoRad MD02EU-MD06EU, a high-performance, shielded power strip designed to protect your sensitive electronics. Featuring Non-Intrusive Filtering (NIF) to reduce RFI interference while preserving audio and video dynamics, it offers multiple filtered outlets and one unfiltered outlet for high-power devices. Available with optional on/off switch and USB charging ports.