Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Baomain KG316T-II 220V DIN-Rail LCD Micro-Computer Electric Power Time Controller. This device is designed to automatically switch electrical equipment on and off according to a fixed time schedule.
It is widely used to control various electrical appliances such as lamps, water heaters, sprayers, preheaters, agricultural facilities, broadcasting equipment, and other home appliances.
General Information
The KG316T-II Panel-Mount Digital Timer series can be operated from 24V to 220V DC/AC. Output format can be voltage-free or voltage-controlled.
Batteries are 1.2VDC / 40mA rechargeable, providing power during power outages. Note: New battery life is 1000 days. If the display is ON but the red light is ON, the battery is charging and should be allowed time to charge. If the display is OFF, the battery is dead and needs replacement.
This Digital Timer is accurate to the minute, designed with either 17 or 18 ON/OFF events per day.

Diagram illustrating the concept of programmed ON/OFF events over time.
The timer supports 15 daily programs, allowing users to choose the required days in a week for operation.
| No. | Days |
|---|---|
| 1. | MO TU WE TH FR SA SU |
| 2. | MO TU WE TH FR SA |
| 3. | MO TU WE TH FR |
| 4. | MO TU WE |
| 5. | MO WE FR |
| 6. | MO TU TH SA |
| 7. | MO TU WE TH FR SA SU |
| 8. | MO |
| 9. | TU |
| 10. | WE |
| 11. | TH |
| 12. | FR |
| 13. | SA |
| 14. | SU |
| 15. | SA SU |
Basic Features
- Panel mounted design.
- Advanced pre-setting one week before operation.
- Digital electronic timer switch with daily & weekly programs.
- Repeat programs with 17 ON/OFF settings and manual override.
- Lithium battery power reserve ensures operation during electric supply cut off.
Technical Data
- Voltage Rating: 12VDC/AC, 24VDC/AC, 48VDC/AC, 110VAC, 220VAC
- Error Correction: 1 second/day (at 25°C)
- ON/OFF Operation: 17 or 18 programs
- Power Consumption: ≤2W
- Service Life: Mechanical 107, Electrical 105
- Display: LCD
- Minimum Interval: 1 minute
- Weight: Approximately 127g
- Power Reserve: 60 days
- Ambient Temperature: -10°C to +40°C
- Ambient Humidity: 35-85%RH
- Battery Life: 3 years (Lithium battery)
Setup and Installation
The Baomain KG316T-II timer switch is designed for DIN-rail mounting. Ensure all power is disconnected before installation.
Physical Dimensions

Detailed dimensions of the timer switch, showing measurements in millimeters for mounting and overall size.
Total Size (Approx): 9.8 x 5.5 x 4.2cm / 3.9" x 2.1" x 1.6" (L*W*H).
Wiring Connection
WARNING: SHOCK OR FIRE HAZARD. Wiring should be performed by qualified personnel. Disconnect power before wiring.

Connection diagram showing power input (L, N) and load output (N, L) terminals for the timer switch. The internal switch is rated for 25A.
Connect the incoming power supply to the "POWER" terminals (L and N). Connect the device to be controlled to the "LOAD" terminals (N and L). Ensure correct polarity and secure all connections.
For 240V applications in the US, connect the two line side wires to the two left side terminals (L and N for input) and the load side to the two right side terminals (N and L for output). Both neutral and ground wires typically bypass the timer.
Operating Instructions
Programming the Timer
The timer features a clear LCD display and several buttons for programming:
- C: Cancel/Reset button.
- D+: Adjust day of the week.
- H+: Adjust hour.
- M+: Adjust minute.
- Clock icon: Set current time.
- P: Program setting button.
- Manual: Toggle ON, AUTO, or OFF.
- Red button: Reset timer before programming.
A. Adjusting Clock
Press and hold the Clock icon button, then press D+, H+, and M+ keys respectively to adjust the current day, hour, and minute. The timer operates in 24-hour format (0:00-23:59).
B. Setting Programs (ON/OFF Operations)
- Press the P key. The LCD screen will show "1st ON".
- Press D+ key to select any of the 15 combinations of daily programs for your application. Repeatedly pressing D+ will cycle through the available day combinations.
- Press H+ and M+ respectively to set the desired hour and minute for the "1st ON" event.
- After finishing setting the "1st ON" event, press the P key again. The screen will now show "1st OFF".
- Press D+ key to select any of the 15 combinations of daily programs for your application. Repeatedly pressing D+ will cycle through the available day combinations.
- Press H+ and M+ respectively to set the desired hour and minute for the "1st OFF" event.
- Repeat steps 3 and 4 to set subsequent ON/OFF programs (up to 17 or 18 pairs).
- After completing all desired program settings, press the Clock icon button to exit programming mode and return to the current time display. The timer will now start to execute the programs.
Important: Day-combination chosen in each of the ON/OFF program periods must be consistent.
Manual Override
Press the Manual button to cycle through the output states: ON, AUTO, or OFF. In AUTO mode, the timer follows the programmed schedule. Manual ON/OFF will override the program until the next programmed event.
Maintenance
The Baomain KG316T-II timer switch requires minimal maintenance. Keep the device clean and free from dust and moisture.
- Cleaning: Use a soft, dry cloth to clean the exterior. Do not use abrasive cleaners or solvents.
- Battery: The built-in lithium battery has an average life of 3 years. If the display is off or the red light is constantly on, the battery may need charging or replacement. Allow time for the battery to charge if the red light is on.
- Storage: If storing the device for an extended period, ensure it is kept in a dry, cool environment within the specified ambient temperature range (-10°C to +40°C).
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is off. | No power supply or dead internal battery. | Check power connections. If power is present, the internal battery may be depleted; allow time for it to charge or consider replacement. |
| Timer not switching at programmed times. | Incorrect programming, timer in manual override mode, or incorrect current time setting. | Verify programmed ON/OFF times. Ensure the timer is set to "AUTO" mode using the Manual button. Check and correct the current time. |
| Red light is ON but display is also ON. | Internal battery is charging. | This is normal operation. Allow the battery to charge. |
| Timer is not responding to button presses. | Unit may be frozen or require a reset. | Press the red reset button to clear all settings and restart. Reprogram the timer as needed. |
| Output not switching despite correct programming. | Wiring issue or faulty unit. | Verify all wiring connections are secure and correct. If problem persists, the unit may be faulty and require replacement. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | KG316T-II-220V |
| Working Rate | AC 220V, 25A, 50/60Hz |
| Built-in Battery | 1.2VDC / 40mA (Lithium Metal) |
| Error Correction | 1 Sec / Day (25°C) |
| ON / OFF Operations | 17 or 18 programs |
| Display | LCD |
| Total Size (Approx) | 9.8 x 5.5 x 4.2cm / 3.9" x 2.1" x 1.6" (L*W*H) |
| Net Weight | 127g (4.5 ounces) |
| Material | Plastic |
| Mounting Type | DIN Rail |
| Minimum Interval | 1 minute |
| Power Reserve | 60 days (battery life 3 years) |
| Ambient Temperature | -10°C to +40°C |
| Ambient Humidity | 35-85%RH |