1. Introduction
This manual provides detailed instructions for the safe and effective use of your Pursonic OI-200 Professional Water Flosser. This device is designed to assist in maintaining oral hygiene by delivering a pulsating stream of water to clean between teeth and below the gumline.
Key features of the Pursonic OI-200 include:
- Adjustable water pressure from 0 to 90 PSI for customized cleaning.
- Advanced pulsation technology to remove food particles and debris.
- A 2-minute auto-timer with 30-second interval alerts for guided cleaning.
- A 360-degree rotatable nozzle for multi-directional cleaning.

Image 1.1: The Pursonic OI-200 Water Flosser and its retail packaging.
2. Safety Information
When using electrical products, especially in the bathroom, basic safety precautions should always be followed. This device is an electrical appliance and should be handled with care. No unusual or specific safety warnings beyond general precautions for an electrical appliance used in the bathroom are required. Always ensure the device is unplugged when not in use or when cleaning. Do not immerse the main unit in water. Keep out of reach of children.
3. What's Included
Your Pursonic OI-200 Professional Water Flosser package includes the following components:
- Pursonic OI-200 Main Unit with Water Reservoir
- Standard Nozzles (quantity may vary, typically 3)
- Tongue Scraper Nozzle
- Nozzle Storage Case
- User Manual

Image 3.1: The Pursonic OI-200 Water Flosser and its included accessories.
4. Setup
Follow these steps for initial setup of your water flosser:
- Place the Unit: Position the water flosser on a flat, stable surface near a power outlet and a sink.
- Fill the Reservoir: Remove the water reservoir from the base. Fill it with lukewarm water. You may also add a small amount of mouthwash if desired. Place the reservoir back onto the base, ensuring it is seated correctly to prevent leaks.
- Insert Nozzle: Select your desired nozzle (standard or tongue scraper). Insert the nozzle into the handle until it clicks into place.
- Connect to Power: Plug the power cord into a grounded electrical outlet.

Image 4.1: Visual guide for adding water and installing the nozzle.
5. Operating Instructions
To use your Pursonic OI-200 Water Flosser:
- Select Pressure Setting: Turn the pressure dial on the main unit to your desired setting. Start with a low setting (1-3) and gradually increase as you become accustomed to the water stream. The device offers 10 pressure settings.
- Prepare for Use: Lean over the sink and place the nozzle tip into your mouth. Close your lips slightly to prevent splashing, but allow water to drain into the sink.
- Start Flossing: Press the ON/OFF button on the main unit to start the water flow. Direct the jet stream at a 90-degree angle to your gumline. Move the nozzle along the gumline, pausing briefly between teeth.
- Utilize Timer: The device features a 2-minute auto-timer with 30-second interval alerts. These alerts indicate when to move to a different section of your mouth (e.g., upper right, upper left, lower left, lower right).
- Pause Function: The handle includes a water flow pause button, allowing you to temporarily stop the water stream without turning off the main unit.
- Complete Session: Continue until the 2-minute timer completes or the reservoir is empty. Turn off the device by pressing the ON/OFF button on the main unit.
- Empty Reservoir: After each use, empty any remaining water from the reservoir to prevent bacterial growth.

Image 5.1: Ergonomic handle design with 360-degree rotation and pause button.

Image 5.2: Overview of the device's key operational features.
6. Maintenance
Proper maintenance ensures the longevity and hygiene of your water flosser:
- Daily Cleaning: After each use, empty any remaining water from the reservoir. Rinse the reservoir with clean water.
- Nozzle Cleaning: Remove the nozzle from the handle. Rinse it under running water. For thorough cleaning, nozzles can be soaked in a solution of 2 parts water to 1 part white vinegar for 5-10 minutes, then rinsed.
- Unit Cleaning: Wipe the exterior of the main unit with a soft, damp cloth. Do not use abrasive cleaners or immerse the unit in water.
- Desealing (if necessary): If mineral deposits build up, fill the reservoir with 2 parts water and 1 part white vinegar. Run a portion of the solution through the unit until it starts to flow, then pause for 20 minutes. Run the remaining solution through the unit. Finish by running a full reservoir of clean water through the unit.
7. Troubleshooting
If you encounter issues with your Pursonic OI-200, refer to the following common problems and solutions:
- No Water Flow:
- Ensure the reservoir is properly seated and filled with water.
- Check that the nozzle is securely inserted into the handle.
- Verify the unit is plugged in and powered on.
- Inspect for any kinks in the water hose.
- Low Water Pressure:
- Adjust the pressure dial to a higher setting.
- Perform a descaling procedure as described in the Maintenance section to remove mineral buildup.
- Leaking:
- Ensure the reservoir is correctly positioned and sealed on the base.
- Check that the nozzle is fully inserted.
If problems persist, contact customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | OI-200 |
| Power Source | Corded Electric |
| Pressure Settings | 0-90 PSI (10 levels) |
| Pulses Per Minute | 1400 |
| Auto-Timer | 2 minutes with 30-second intervals |
| Product Dimensions | 6.75 x 6 x 9 inches |
| Item Weight | 1.8 Pounds |
| Manufacturer | Samsonic Trading Company, Inc |
9. Warranty and Support