Lightolier ITSEBULA

Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch User Manual

Model: ITSEBULA

Introduction

This manual provides instructions for the installation, operation, and maintenance of the Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch. This device is designed to automatically control lighting based on occupancy detection, offering energy efficiency and convenience for permanently installed fixtures.

Safety Information

WARNING: Risk of Electric Shock. Installation requires knowledge of electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

Package Contents

Verify that your package contains the following items:

Specifications

FeatureDetail
ModelITSEBULA
BrandLightolier
TypeOccupancy Sensing Dimmer Switch
Power Rating1000W
Voltage120/277V
Frequency60 Hz
ColorWhite
Connectivity ProtocolWi-Fi
Mounting TypeWall Mount
CompatibilityFor permanently installed fixtures only. Compatible with ADVANCE® MARK 10® and OSRAM® SYLVANIA QUICKTRONIC® POWERENSE® fluorescent dimming ballasts.

Note: The Wi-Fi connectivity protocol listed in specifications may indicate advanced features not detailed in this basic manual. Refer to additional documentation for Wi-Fi setup and functionality if applicable.

Setup and Installation

Important: Installation should be performed by a qualified electrician or a person with thorough knowledge of electrical wiring. Ensure power is OFF at the circuit breaker before proceeding.

  1. Turn Off Power: Locate the circuit breaker controlling the light fixture and turn it OFF. Verify power is off using a voltage tester.
  2. Remove Existing Switch: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires.
  3. Identify Wires: Identify the Line (hot), Load (to fixture), Neutral (if present), and Ground wires.
  4. Wire the Dimmer: Connect the wires to the Lightolier ITSEBULA dimmer switch according to the wiring diagram provided with the product (not included in this manual).

    Typical Wiring:

    • Connect the Line wire to the dimmer's Line terminal.
    • Connect the Load wire to the dimmer's Load terminal.
    • Connect the Ground wire to the dimmer's Ground terminal.
    • If a Neutral wire is present and required by the dimmer, connect it to the dimmer's Neutral terminal.
  5. Mount the Dimmer: Carefully push the wired dimmer into the wall box and secure it with screws.
  6. Install Wall Plate: Attach the new or existing wall plate.
  7. Restore Power: Turn the power back ON at the circuit breaker.
Front view of the Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch in white, showing the 'ON' button and the occupancy sensor lens.
Figure 1: Front view of the Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch. This image displays the main control button labeled 'ON' and the integrated occupancy sensor lens, indicating its primary function.
Packaging of the Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch, showing product name, specifications like 1000W 120/277VAC 60HZ, and compatibility information.
Figure 2: Packaging of the Lightolier ITSEBULA Intellisight Occupancy Sensing Dimmer Switch. The packaging highlights key features such as "Intellisight Occupancy Sensing Dimmer ITSEBULA" and electrical specifications (1000W 120/277VAC 60HZ), along with compatibility for specific fluorescent dimming ballasts.

Operating Instructions

The Lightolier ITSEBULA dimmer switch combines manual control with automatic occupancy sensing.

Manual Operation

Occupancy Sensing

Note: The Wi-Fi connectivity mentioned in specifications may allow for advanced control and scheduling via a compatible app. Consult the manufacturer's website or additional documentation for details on Wi-Fi setup and features.

Maintenance

No user-serviceable parts inside.

Troubleshooting

ProblemPossible CauseSolution
Lights do not turn onNo power to the switchCheck circuit breaker.
Lights do not turn onIncorrect wiringVerify wiring connections. Consult a qualified electrician.
Lights do not turn onBulb(s) burned outReplace bulb(s).
Lights turn on unexpectedlySensor sensitivity too highAdjust sensor sensitivity (if adjustable).
Lights turn off too quicklyTime delay too shortAdjust time delay setting (if adjustable).
Lights turn off too quicklyObstruction blocking sensorClear any objects blocking the sensor's view.
Dimming not workingIncompatible fixture/bulbEnsure fixtures and bulbs are dimmable and compatible with this dimmer type.

Warranty and Support

Lightolier products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official Lightolier website.

For technical support, product inquiries, or to locate authorized service centers, please contact Lightolier customer service.

Manufacturer: Lightolier

Website: www.lightolier.com (General manufacturer website, specific support link may vary)

Phone: (Refer to manufacturer's website for current contact information)

Related Documents - ITSEBULA

Preview Lightolier IS-RD_R LED Retrofit Downlight Installation Instructions
Detailed installation and removal instructions for the Lightolier IS-RD_R LED Retrofit Downlight, including safety warnings, compliance information, and dimensional requirements for recessed housings.
Preview Calculite LED Accessories: Emergency Battery Pack Installation Guide (IS_CAEM6)
Step-by-step installation instructions for Lightolier's Calculite LED Accessories emergency battery pack (model IS_CAEM6), including wiring and test switch mounting.
Preview Lightolier IS:1005 Installation Instructions for Lytecaster Reflector Trim
Detailed installation guide for Lightolier Lytecaster Reflector Trim in 1000 Series Frame-In Kits, covering various models and steps. Includes safety warnings, product specifications, and assembly procedures.
Preview Lightolier Calculite LED 3" C3RWW Round Wall Wash Downlight Specification Sheet
Detailed specification sheet for the Lightolier Calculite LED 3" C3RWW round wall wash downlight, covering features, ordering information, technical specifications, dimming options, controls, and photometric data.
Preview Calculite IS-C_RVP Vandal Resistant Accessory Installation Guide
Detailed installation instructions for the Lightolier Calculite IS-C_RVP vandal resistant accessory. Learn how to install this accessory for grid ceiling applications with compatible Calculite downlight frame-in sections.
Preview Lightolier ModuLyte Cylinder Configuration Installation Guide
Comprehensive installation instructions for the Lightolier ModuLyte Cylinder Configuration, including surface mount and pendant mount options. Covers safety, parts, steps, and electrical diagrams for models IS MCR, 442296608931, ModuLyte Cylinder 4 & 6 in.