The TOYOTOMI TAD-22FW(W) is a versatile portable air conditioner designed to provide both cooling and heating functions, along with dehumidification and fan-only modes. Its portable design with casters allows for easy relocation, making it suitable for various spaces where traditional air conditioning installation is not feasible. This unit is equipped with a simple window panel for efficient exhaust heat management and a remote control for convenient operation.

Image 1: The TOYOTOMI TAD-22FW(W) portable air conditioner in a garage setting, highlighting its mobility and all-season use.

Image 2: Overview of the TAD-22FW(W) unit, detailing its modes (Cooling, Heating, Dry, Fan), remote control, and casters.
2. Safety Information
Please read all safety instructions carefully before operating the unit to prevent injury or damage.
- Always ensure the exhaust duct is properly attached and vented outdoors when using cooling or heating functions. Failure to do so will result in inefficient operation and may cause the room temperature to rise.
- During heating mode, the unit will produce drain water that needs to be manually managed. Prepare a low-profile tray or a commercially available drain hose for proper disposal.
- When the window panel is installed, the window cannot be opened or closed. Ensure this is acceptable for your installation location.
- Do not obstruct the air intake or exhaust vents. Maintain adequate clearance around the unit for proper airflow.
- This unit is designed for indoor use. Do not expose it to rain or moisture.
3. Package Contents
Verify that all the following items are included in your package:
- TOYOTOMI TAD-22FW(W) Main Unit
- Intake Duct
- Exhaust Duct
- Resin Window Panel Set
- Drain Hose
- Activated Carbon Filter
- Remote Control (batteries not included)

Image 3: Illustration of the included accessories: intake/exhaust ducts, resin window panel, and drain hose.
4. Setup
4.1. Placement
Place the unit on a flat, stable surface. Ensure there is sufficient space around the unit for proper airflow. The unit is equipped with casters for easy movement.
4.2. Window Panel Installation
The included resin window panel set allows for easy installation without requiring construction. This panel is crucial for directing exhaust heat outdoors, improving cooling efficiency.
- Adjust the window panel to fit your window opening.
- Secure the panel in place.
- Attach the exhaust duct to the opening in the window panel.
- Connect the other end of the exhaust duct to the unit's exhaust port.
Note: Installation may require tools other than a screwdriver. Refer to the separate detailed instructions provided with the window panel for specific steps.

Image 4: Visual representation of the window panel installation, showing how exhaust heat is directed outside.
4.3. Drain Hose Connection (for Heating Mode)
During heating operation, the unit will produce condensate that needs to be drained. Connect the drain hose to the unit's drain outlet and direct it to a suitable drainage point or collection tray.
5. Operating Instructions
5.1. Power On/Off
Press the Power button on the control panel or remote control to turn the unit on or off.
5.2. Mode Selection
Use the Mode button to cycle through the available operating modes:
- Cooling Mode: Provides powerful cooling. Operating temperature range: 16-35°C.
- Heating Mode: Provides warmth. Operating temperature range: 12-25°C.
- Dry Mode (Dehumidification): Reduces humidity in the room.
- Fan Mode: Circulates air without cooling or heating.
- Automatic Mode: The unit automatically selects the appropriate mode based on the ambient temperature.
5.3. Temperature Adjustment
In Cooling or Heating mode, use the Up/Down arrow buttons on the control panel or remote control to set your desired temperature.
5.4. Timer Function
The unit features a 1 to 12-hour ON/OFF timer. This function allows you to set a specific time for the unit to turn on or off automatically. The ON and OFF timers cannot be used simultaneously.
5.5. Airflow Direction
Manually adjust the up/down airflow direction to optimize air distribution in the room.
5.6. Remote Control
The detachable remote control allows convenient operation from a distance of 6-7 meters. Ensure batteries are correctly inserted.
6. Maintenance
6.1. Anti-bacterial Filter Cleaning
The unit is equipped with an anti-bacterial filter at the air intake. Regular cleaning of this filter is essential to maintain air quality and unit efficiency. Refer to the detailed cleaning instructions in the full manual.
6.2. Drainage Management
During cooling and dry modes, the unit utilizes a non-drainage mechanism that evaporates condensate using exhaust heat. However, if humidity is very high, some water may still collect. During heating mode, condensate will always be produced and requires manual drainage via the drain hose or a collection tray.

Image 5: Details on power consumption, cooling/heating capacity, dehumidification, non-drainage feature, and the anti-bacterial filter.
7. Troubleshooting
If you encounter issues with your TOYOTOMI TAD-22FW(W), please refer to the following common solutions:
- Unit not cooling/heating effectively: Ensure the exhaust duct is securely attached and vented outdoors. Check for any gaps around the window panel and seal them if necessary. Clean the air filter.
- Airflow stops intermittently during heating: This is normal. If the ambient temperature drops below approximately 12°C, the unit will perform internal defrosting, temporarily pausing airflow.
- Room temperature rises during operation: This indicates that the exhaust heat is not being properly vented outside. Verify that the exhaust duct is correctly installed and that the unit is not operating in a completely closed room without proper ventilation.
- Loud operating noise: Portable air conditioners typically produce more noise than split-type units due to the compressor being integrated into the main unit. Ensure the unit is on a stable surface and not vibrating against other objects.
- Water leakage: Check the drain hose connection, especially during heating mode. Ensure the hose is not kinked or blocked and that the drainage point is lower than the unit's drain outlet.
If the problem persists after attempting these solutions, please contact customer support.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | TAD-22FW(W) |
| Dimensions (W x H x D) | 44 x 69 x 32 cm |
| Weight | 26 kg (30800 grams) |
| Power Supply | AC100V 50/60Hz |
| Power Consumption (Cooling) | 50Hz: 590W / 60Hz: 690W |
| Power Consumption (Heating) | 50Hz: 600W / 60Hz: 730W |
| Cooling Capacity | 50Hz: 2.0kW / 60Hz: 2.2kW |
| Heating Capacity | 50Hz: 1.7kW / 60Hz: 1.9kW |
| Dehumidifying Capacity | 50Hz: 36L/day / 60Hz: 42L/day |
| Cord Length | 2.5m |
| Control Method | Remote Control |
| Special Features | Dehumidifier, Heating and Cooling functions, Portable |
| Country of Origin | China |
9. Warranty and Support
9.1. Warranty Information
This TOYOTOMI TAD-22FW(W) unit comes with a 1 Year Limited Warranty from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.
9.2. Customer Support
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact the retailer where you purchased the product or visit the official TOYOTOMI website for support contact information.