1. Introduction
This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Carrier Original Parts Blower Motor, model HC43TE113. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent potential hazards. Retain this manual for future reference.
2. Safety Information
WARNING: Electrical shock hazard. Disconnect all power to the unit before installing or servicing this motor. Failure to do so may result in serious injury or death.
CAUTION: This motor should only be installed by a qualified HVAC technician. Improper installation can lead to equipment damage, fire, or personal injury.
- Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the motor if it is damaged or if any components are missing.
- Keep hands and loose clothing away from moving parts.
3. Product Overview

Figure 3.1: A detailed view of the Carrier HC43TE113 Blower Motor, showing its cylindrical body, mounting brackets, electrical wiring, and extended shaft. This image illustrates the motor's physical configuration and connection points.
The Carrier HC43TE113 is an original replacement blower motor designed for HVAC systems. It features a robust construction and is engineered to meet the specific performance requirements of Carrier equipment. This motor is a 1/2 horsepower (HP) unit, operating at 115 volts and 1075 revolutions per minute (RPM) with three speeds. It includes a 1/2 x 3.25 inch shaft and a 48-frame size with ball bearings and vertical shaft up (VSU) mounting.
4. Specifications
| Feature | Detail |
|---|---|
| Brand | Carrier |
| Model Number | HC43TE113 |
| Horsepower (HP) | 0.5 HP (1/2 HP) |
| Voltage | 115V |
| Speed | 1075 RPM (3-speed) |
| Shaft Size | 1/2 x 3.25 inches |
| Frame Size | 48 |
| Bearing Type | Ball Bearing |
| Mounting | Vertical Shaft Up (VSU) |
| Material | Copper (windings) |
5. Setup and Installation
Installation of the Carrier HC43TE113 blower motor requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC professional.
- Power Disconnection: Ensure all electrical power to the HVAC unit is completely disconnected at the main breaker before beginning any work. Verify with a voltage tester.
- Access Blower Compartment: Open the access panel to the blower compartment of your HVAC unit.
- Remove Old Motor:
- Carefully disconnect all wiring from the old motor, noting the position and color of each wire for correct re-connection. Take photos if necessary.
- Loosen the set screw(s) holding the blower wheel to the motor shaft and slide the blower wheel off.
- Unbolt or unmount the old motor from its housing or mounting brackets.
- Install New Motor:
- Mount the new HC43TE113 motor using the existing mounting brackets or housing. Ensure it is securely fastened.
- Slide the blower wheel onto the new motor shaft. Align the set screw(s) with the flat part of the shaft and tighten securely. Ensure the blower wheel is centered and spins freely without rubbing.
- Connect the electrical wiring to the new motor according to the wiring diagram provided with your HVAC unit or the old motor's configuration. Pay close attention to the speed tap connections.
- Verify Connections: Double-check all electrical connections and mechanical fastenings. Ensure no wires are pinched or exposed.
- Restore Power: Close the blower compartment access panel. Restore power to the HVAC unit.
- Test Operation: Test the HVAC system to ensure the new blower motor operates correctly across all speeds. Listen for unusual noises or vibrations.
6. Operating Instructions
The Carrier HC43TE113 blower motor operates as an integral component of your HVAC system. Its operation is controlled by the thermostat and the system's control board. Once installed, the motor will engage automatically when heating, cooling, or fan-only modes are activated.
- Fan Speeds: This motor is a 3-speed unit. The specific speed used will depend on the HVAC system's configuration and the demand for airflow (e.g., heating, cooling, continuous fan).
- Normal Operation: During normal operation, the motor should run smoothly with a consistent hum. Any unusual noises, vibrations, or burning smells indicate a potential issue.
- Thermostat Control: Adjust your thermostat to control the fan operation. Settings typically include AUTO (fan runs only when heating/cooling) and ON (fan runs continuously).
7. Maintenance
Regular maintenance helps ensure the longevity and efficient operation of your blower motor. Always disconnect power before performing any maintenance.
- Blower Wheel Cleaning: Annually, inspect and clean the blower wheel. Dust and debris buildup on the wheel can reduce airflow and put strain on the motor.
- Motor Inspection: Periodically check the motor for any signs of wear, such as loose wiring, corrosion, or excessive dust accumulation.
- Air Filter Replacement: Ensure the HVAC system's air filter is replaced regularly (typically every 1-3 months). A clogged filter restricts airflow, causing the blower motor to work harder and potentially overheat.
- Lubrication: This motor features ball bearings, which are typically sealed and do not require lubrication. Refer to your HVAC unit's specific manual for any lubrication requirements for other components.
8. Troubleshooting
If you experience issues with your blower motor, refer to the following common troubleshooting steps. For complex problems, contact a qualified HVAC technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor does not start | No power, faulty wiring, seized motor, bad capacitor (if applicable) | Check circuit breaker. Verify wiring connections. Inspect motor for obstructions. Consult technician for motor/capacitor testing. |
| Motor runs but no airflow | Blower wheel loose on shaft, obstructed ductwork, clogged air filter | Ensure blower wheel set screw is tight. Check and replace air filter. Inspect ductwork for blockages. |
| Unusual noises (squealing, grinding) | Worn bearings, debris in blower wheel, loose mounting | Inspect blower wheel for debris. Check motor mounting. Worn bearings typically require motor replacement. |
| Motor overheats and shuts off | Restricted airflow (clogged filter/coil), motor overload, incorrect voltage | Replace air filter. Clean evaporator/condenser coils. Verify correct voltage supply. |
9. Warranty and Support
For warranty information regarding your Carrier Original Parts Blower Motor HC43TE113, please refer to the documentation provided with your original HVAC equipment or contact Carrier customer support directly. Warranty terms typically cover manufacturing defects for a specified period.
For technical support, service, or to locate authorized Carrier service providers, please visit the official Carrier website or contact their customer service department. When contacting support, have your motor model number (HC43TE113) and the serial number of your HVAC unit readily available.
Carrier Official Website: www.carrier.com