GOWE GWE-1005998
GOWE LUGB Vortex Street Flow Meter Instruction Manual
Model: GWE-1005998
Introduction
This manual provides essential information for the proper installation, operation, and maintenance of the GOWE LUGB vortex street flow meter. This device is designed for precise measurement of various media including air, gas, steam, and low viscosity liquids, with integrated temperature and pressure compensation.
Product Overview

Image: GOWE LUGB Vortex Street Flow Meter. This image displays the complete assembly of the vortex street flow meter, featuring the main body with flanges for pipe connection, the vertical stem leading to the integrated display unit at the top, and a coiled tube for temperature/pressure compensation connected to the display unit.
The GOWE LUGB vortex street flow meter is a robust instrument designed for industrial applications requiring accurate flow measurement. Its integrated design allows for temperature and pressure compensation, ensuring high precision across varying conditions. The device features a clear display for instantaneous flow, flow rate, and cumulative percentage flow, along with programmable pulse output and sensor vortex street frequency output.
Key Features
- Versatile Measurement: Capable of measuring air, gas, steam, and low viscosity liquids.
- Corrosion Resistance: Designed to measure various corrosive media.
- Wide Temperature Range: Operates effectively in temperatures from -50°C to +400°C.
- High Accuracy: Liquid measurement accuracy of ±1% (ordinary) or ±0.5% (special), Gas measurement accuracy of ±1%.
- Robust Construction: Body material 1Cr18Ni9Ti, sensor seal with graphite gaskets, IP67 protection grade.
- Flexible Power: Requires 12-36 VDC power supply.
- Multiple Outputs: Features two-wire system 4-20mA current output, programmable pulse output, and sensor vortex street frequency output.
- On-site Display: Programmable display for instantaneous flow, flow rate, and cumulative percentage flow.
Specifications
| Parameter | Value |
|---|---|
| Measuring Quantity Interface Mass | Air, gas, steam, gas and water, low viscosity liquid |
| Corrosion Type Flowmeter Measurement | All kinds of corrosive medium |
| Intermediate Mass Viscosity | Less than 10 cP |
| Intermediate Mass Temperature | -50°C to +400°C |
| Body Material | 1Cr18Ni9Ti (other materials by agreement) |
| Sensor Seal | Graphite gaskets |
| Environment Temperature | -30°C to +80°C (special request) |
| Nominal Diameter (DN) | DN15-DN1200 |
| Measuring Accuracy (Liquid) | ±1% (ordinary), ±0.5% (special) |
| Measuring Accuracy (Gas) | ±1% |
| Pressure Level | PN25, PN40 (high pressure can be special manufacturing) |
| Connection Type | Holding type: DN15-600; Flange: DN15-1200 |
| Protection Grade | IP67 |
| Converter Shell | Die casting aluminum, paint |
| Power Supply | 12-36 VDC |
| Output Signal | Two-wire system 4-20mA current output, Programmable pulse output, Sensor vortex street frequency output |
| Display | Programmable set display instantaneous flow, flow rate and cumulative percentage flow |
Setup and Installation
Proper installation is crucial for the accurate and reliable operation of the GOWE LUGB vortex street flow meter. It is recommended that installation be performed by qualified personnel.
- Site Selection: Choose a location with stable temperature and minimal vibration. Ensure sufficient straight pipe lengths upstream and downstream as per industry standards (typically 10-20D upstream and 5D downstream, where D is the nominal diameter).
- Mounting Orientation: Install the flow meter in a horizontal or vertical pipeline, ensuring the flow direction arrow on the meter body aligns with the actual fluid flow.
- Flange Connection: Use appropriate gaskets and tighten bolts evenly to prevent leaks. Ensure the meter is properly aligned with the pipeline.
- Electrical Connections: Connect the power supply (12-36 VDC) and output signals (4-20mA, pulse) according to the wiring diagram provided with the product. Ensure proper grounding to prevent electrical interference.
- Pressure and Temperature Compensation Lines: If applicable, connect the pressure and temperature compensation lines to the appropriate points on the pipeline and the meter's compensation unit.
- Initial Power-Up: After installation, apply power and observe the display. Verify basic functionality before introducing process fluid.
Note: Refer to the detailed wiring diagrams and specific installation guidelines included in the product packaging for precise instructions.
Operating Instructions
Once installed and powered, the GOWE LUGB vortex street flow meter is designed for continuous operation. The integrated display provides real-time data.
- Display Navigation: Use the buttons on the display unit (if present) to cycle through different readings such as instantaneous flow, totalized flow, and percentage flow.
- Parameter Configuration: Access the configuration menu (refer to the product's specific manual for access method) to set parameters such as fluid type, pipe diameter, and output scaling.
- Monitoring Output: Monitor the 4-20mA current output or pulse output at your control system to integrate the flow data into your process control.
- Data Logging: If connected to a data logging system, ensure data is being recorded correctly.
Always ensure the process fluid is within the specified temperature and pressure limits of the flow meter.
Maintenance
Regular maintenance ensures the longevity and accuracy of your flow meter.
- Routine Inspection: Periodically inspect the meter for any signs of leakage, corrosion, or physical damage. Check electrical connections for tightness.
- Cleaning: Keep the exterior of the meter clean. Avoid using abrasive cleaners.
- Sensor Check: While the vortex sensor is generally robust, ensure there are no obstructions or build-up within the flow path that could affect accuracy. This may require temporary removal from the pipeline.
- Recalibration: Depending on application and regulatory requirements, periodic recalibration may be necessary to maintain accuracy. Consult a qualified technician for recalibration services.
- Gasket Replacement: If the meter is removed from the pipeline for any reason, always replace the gaskets before reinstallation.
Before performing any maintenance, ensure the process fluid flow is stopped, the pipeline is depressurized, and the meter's power supply is disconnected.
Troubleshooting
This section provides common issues and their potential solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Meter not powering on | No power supply; Incorrect wiring; Blown fuse | Check power source (12-36 VDC); Verify wiring connections; Replace fuse if necessary. |
| Inaccurate readings | Incorrect installation (e.g., insufficient straight pipe); Sensor fouling; Air bubbles/cavitation in fluid; Incorrect parameter settings | Review installation guidelines; Clean sensor; Ensure stable fluid conditions; Verify configuration parameters. |
| No output signal (4-20mA/pulse) | Wiring error; Faulty output module; Incorrect output settings | Check output wiring to control system; Consult technical support if module is suspected faulty; Verify output settings in meter configuration. |
| Leakage at connections | Improperly tightened flanges; Damaged gaskets | Retighten flange bolts evenly; Replace gaskets. |
If the problem persists after attempting these solutions, contact GOWE technical support.
Warranty and Support
GOWE products are manufactured to high standards. For information regarding product warranty, please refer to the warranty card included with your purchase or contact the seller directly. Protection plans are also available for extended coverage.
For technical assistance, troubleshooting beyond this manual, or spare parts inquiries, please contact Gowegroup, the manufacturer and seller of this product. You can visit their store on Amazon for more information: GOWE Amazon Store.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.