EISCO PH1058A
Eisco Labs Copper Wire User Manual
Model: PH1058A
1. Introduction
This manual provides essential information for the safe and effective use of the Eisco Labs Copper Wire. Please read this manual thoroughly before use and retain it for future reference.
The Eisco Labs Copper Wire is a bare, uninsulated copper wire, supplied on a reel. It is suitable for various scientific, educational, and crafting applications where a conductive material is required.
2. Product Overview
The Eisco Labs Copper Wire is characterized by its specific gauge and length, provided in a convenient reel format.

Figure 2.1: Eisco Labs Copper Wire, 14 SWG (12 AWG), on a black plastic reel. The wire is bright copper colored and neatly wound, with a label on top indicating "Bare Cu Wire 14G Qty. 500gm."

Figure 2.2: Side view of the Eisco Labs Copper Wire reel, showing the tightly wound copper wire. A loose end of the wire is visible, extending from the main coil.

Figure 2.3: Top-down perspective of the Eisco Labs Copper Wire reel, highlighting the label "Bare Cu Wire 14 SWG Qty. 500gm." and the uniform winding of the copper wire.
3. Specifications
The following table details the technical specifications of the Eisco Labs Copper Wire:
| Attribute | Value |
|---|---|
| Product Name | Eisco Labs Copper Wire |
| Model Number | PH1058A |
| Material | Copper |
| Gauge (SWG) | 14 SWG |
| Gauge (AWG) | 12 AWG |
| Diameter | 0.08" (2.0 mm) |
| Approximate Length | 50 ft |
| Weight (approx.) | 500g (1.11 Pounds) |
| Finish Type | Polished |
| UPC | 849230051242 |
4. Setup and Handling
The Eisco Labs Copper Wire is supplied on a reel for ease of dispensing and storage. No complex setup is required.
4.1 Unpacking
- Carefully remove the copper wire reel from its packaging.
- Inspect the wire for any visible damage or kinks. If damage is present, do not use and contact supplier.
4.2 Handling Precautions
- Always handle the wire with care to avoid kinking or damaging the conductor.
- Wear appropriate personal protective equipment (PPE), such as gloves, to prevent cuts or abrasions from sharp wire ends.
- Ensure the work area is clean and free of debris that could contaminate or damage the wire.
5. Operating Instructions
This bare copper wire is intended for applications requiring electrical conductivity, heat conductivity, or malleability for shaping. Common uses include:
- Electrical Circuits: For creating temporary circuits, educational demonstrations, or low-voltage wiring where insulation is not required or will be added separately.
- Crafts and Sculpture: Its malleability makes it suitable for artistic projects, jewelry making, or model building.
- Science Experiments: Ideal for experiments demonstrating conductivity, electromagnetism, or material properties.
5.1 Dispensing Wire
- Place the reel on a stable surface.
- Gently pull the desired length of wire from the reel. Avoid pulling too quickly or with excessive force, which can cause tangles or kinks.
- Use appropriate wire cutters to cut the wire to the required length.
5.2 Safety Considerations
- This wire is bare and uninsulated. Always assume it is electrically live if connected to a power source.
- Do not use this wire for household electrical wiring or any application requiring insulated wire unless proper insulation is applied by a qualified professional.
- Avoid contact with sharp edges of cut wire.
- Ensure proper ventilation if soldering or heating the wire, as fumes may be produced.
6. Maintenance and Storage
Proper maintenance and storage will prolong the life and usability of your copper wire.
6.1 Cleaning
- If the wire becomes tarnished or dirty, it can be cleaned with a mild abrasive cleaner or a specialized copper cleaner.
- Ensure the wire is completely dry before storage or use, especially if used in electrical applications.
6.2 Storage
- Store the copper wire reel in a cool, dry place away from direct sunlight and moisture.
- Keep the wire on its original reel to prevent tangling and damage.
- Avoid storing near corrosive chemicals or environments that could accelerate oxidation (tarnishing) of the copper.
7. Troubleshooting
This section addresses common issues that may arise during the use of the copper wire.
| Problem | Possible Cause | Solution |
|---|---|---|
| Wire appears tarnished or discolored. | Oxidation due to exposure to air and moisture. | Clean the wire with a copper cleaner or fine abrasive. Store in a dry, sealed environment. |
| Wire is kinked or bent. | Improper handling or storage. | Straighten carefully if possible. For critical applications, cut off damaged sections. Handle gently. |
| Difficulty dispensing from reel. | Wire tangled or reel obstructed. | Ensure the reel is on a flat surface. Gently untangle any snags. Do not force the wire. |
8. Warranty and Support
For information regarding product warranty, returns, or technical support, please refer to the purchase documentation or contact EISCO directly.
Manufacturer: EISCO
Website: Visit the EISCO Store on Amazon
Date First Available: August 27, 2014
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.