EISCO PH1058A

Eisco Labs Copper Wire User Manual

Model: PH1058A

1. Introduction

This manual provides essential information for the safe and effective use of the Eisco Labs Copper Wire. Please read this manual thoroughly before use and retain it for future reference.

The Eisco Labs Copper Wire is a bare, uninsulated copper wire, supplied on a reel. It is suitable for various scientific, educational, and crafting applications where a conductive material is required.

2. Product Overview

The Eisco Labs Copper Wire is characterized by its specific gauge and length, provided in a convenient reel format.

Eisco Labs Copper Wire on Reel

Figure 2.1: Eisco Labs Copper Wire, 14 SWG (12 AWG), on a black plastic reel. The wire is bright copper colored and neatly wound, with a label on top indicating "Bare Cu Wire 14G Qty. 500gm."

Side view of Eisco Labs Copper Wire Reel

Figure 2.2: Side view of the Eisco Labs Copper Wire reel, showing the tightly wound copper wire. A loose end of the wire is visible, extending from the main coil.

Top-down view of Eisco Labs Copper Wire Reel

Figure 2.3: Top-down perspective of the Eisco Labs Copper Wire reel, highlighting the label "Bare Cu Wire 14 SWG Qty. 500gm." and the uniform winding of the copper wire.

3. Specifications

The following table details the technical specifications of the Eisco Labs Copper Wire:

AttributeValue
Product NameEisco Labs Copper Wire
Model NumberPH1058A
MaterialCopper
Gauge (SWG)14 SWG
Gauge (AWG)12 AWG
Diameter0.08" (2.0 mm)
Approximate Length50 ft
Weight (approx.)500g (1.11 Pounds)
Finish TypePolished
UPC849230051242

4. Setup and Handling

The Eisco Labs Copper Wire is supplied on a reel for ease of dispensing and storage. No complex setup is required.

4.1 Unpacking

  1. Carefully remove the copper wire reel from its packaging.
  2. Inspect the wire for any visible damage or kinks. If damage is present, do not use and contact supplier.

4.2 Handling Precautions

  • Always handle the wire with care to avoid kinking or damaging the conductor.
  • Wear appropriate personal protective equipment (PPE), such as gloves, to prevent cuts or abrasions from sharp wire ends.
  • Ensure the work area is clean and free of debris that could contaminate or damage the wire.

5. Operating Instructions

This bare copper wire is intended for applications requiring electrical conductivity, heat conductivity, or malleability for shaping. Common uses include:

  • Electrical Circuits: For creating temporary circuits, educational demonstrations, or low-voltage wiring where insulation is not required or will be added separately.
  • Crafts and Sculpture: Its malleability makes it suitable for artistic projects, jewelry making, or model building.
  • Science Experiments: Ideal for experiments demonstrating conductivity, electromagnetism, or material properties.

5.1 Dispensing Wire

  1. Place the reel on a stable surface.
  2. Gently pull the desired length of wire from the reel. Avoid pulling too quickly or with excessive force, which can cause tangles or kinks.
  3. Use appropriate wire cutters to cut the wire to the required length.

5.2 Safety Considerations

  • This wire is bare and uninsulated. Always assume it is electrically live if connected to a power source.
  • Do not use this wire for household electrical wiring or any application requiring insulated wire unless proper insulation is applied by a qualified professional.
  • Avoid contact with sharp edges of cut wire.
  • Ensure proper ventilation if soldering or heating the wire, as fumes may be produced.

6. Maintenance and Storage

Proper maintenance and storage will prolong the life and usability of your copper wire.

6.1 Cleaning

  • If the wire becomes tarnished or dirty, it can be cleaned with a mild abrasive cleaner or a specialized copper cleaner.
  • Ensure the wire is completely dry before storage or use, especially if used in electrical applications.

6.2 Storage

  • Store the copper wire reel in a cool, dry place away from direct sunlight and moisture.
  • Keep the wire on its original reel to prevent tangling and damage.
  • Avoid storing near corrosive chemicals or environments that could accelerate oxidation (tarnishing) of the copper.

7. Troubleshooting

This section addresses common issues that may arise during the use of the copper wire.

ProblemPossible CauseSolution
Wire appears tarnished or discolored.Oxidation due to exposure to air and moisture.Clean the wire with a copper cleaner or fine abrasive. Store in a dry, sealed environment.
Wire is kinked or bent.Improper handling or storage.Straighten carefully if possible. For critical applications, cut off damaged sections. Handle gently.
Difficulty dispensing from reel.Wire tangled or reel obstructed.Ensure the reel is on a flat surface. Gently untangle any snags. Do not force the wire.

8. Warranty and Support

For information regarding product warranty, returns, or technical support, please refer to the purchase documentation or contact EISCO directly.

Manufacturer: EISCO

Website: Visit the EISCO Store on Amazon

Date First Available: August 27, 2014

© 2024 EISCO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.