Product Overview
The Cool Living 5,000 BTU 9.7 EER 115V Window Mount Room Air Conditioner AC Unit is designed to provide efficient cooling for small to medium-sized rooms. With its compact design and user-friendly controls, it offers a comfortable indoor environment.

Figure 1: Front view of the Cool Living 5,000 BTU Window Mount Room Air Conditioner.
Key Features:
- Cools room sizes up to 150 square feet with 5,000 BTUs of power.
- Offers 3 cool settings and 3 fan speeds for personalized comfort.
- Features side-out filter access for easy cleaning or replacement.
- Utilizes eco-friendly R410A refrigerant.
- Includes a fitting kit for convenient window installation.
Setup (Installation)
Before You Begin:
Ensure your window dimensions are compatible with the unit. The air conditioner is designed for standard vertical sliding windows. Verify that you have a suitable 115V electrical outlet nearby.

Figure 2: Product dimensions for installation planning.
Window Mounting Steps:
- Prepare the window opening by cleaning the sill and frame.
- Attach the top and bottom mounting rails to the air conditioner unit as per the fitting kit instructions.
- Carefully lift the unit and place it into the window opening. Ensure the bottom rail rests securely on the window sill.
- Extend the side panels to fill the window opening completely. Secure them with screws provided in the kit.
- For proper drainage of condensed water, ensure the unit is slightly tilted outwards. The included foam pieces or similar material can be used to prop up the inner side of the unit, allowing water to drain effectively to the outside.
- Lower the window sash behind the top rail of the air conditioner to secure it in place.
- Install the window sash lock bracket and seal any gaps around the unit with the provided weatherstripping to prevent air leakage.

Figure 3: Air conditioner installed in a window.
Operating Instructions
Understanding the Controls:
The Cool Living air conditioner features straightforward manual controls located on the front panel.

Figure 4: Close-up of the control panel.
- Thermostat Knob: This knob controls the desired temperature. Turn it clockwise for cooler settings (higher numbers) and counter-clockwise for warmer settings (lower numbers).
- Operation Knob: This knob selects the operating mode and fan speed.
Cooling Modes and Fan Speeds:
Select the desired mode using the Operation Knob:
- OFF: Turns the unit off.
- Low Fan: Operates the fan at a low speed without cooling.
- Med Fan: Operates the fan at a medium speed without cooling.
- Hi Fan: Operates the fan at a high speed without cooling.
- Low Cool: Provides cooling with the fan operating at a low speed.
- Med Cool: Provides cooling with the fan operating at a medium speed.
- Hi Cool: Provides maximum cooling with the fan operating at a high speed.
Adjust the thermostat knob to your preferred temperature setting. The unit will cycle on and off to maintain the set temperature.
Maintenance
Air Filter Cleaning:
Regular cleaning of the air filter is crucial for optimal performance and air quality. The filter is easily accessible from the side of the unit.

Figure 5: Location of the side-out air filter.
- Turn off the air conditioner and unplug it from the power outlet.
- Locate the filter access on the side of the unit and slide out the filter.
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it into the unit.
- It is recommended to clean the filter every two weeks, or more frequently depending on usage and air quality.
Troubleshooting Common Issues
If you experience issues with your air conditioner, refer to the following common problems and solutions:
- Unit does not turn on:
Ensure the power cord is securely plugged into a functioning 115V outlet. Check your home's circuit breaker. - Air conditioner does not cool:
Verify that the thermostat is set to a cooler temperature than the room. Check if the air filter is clean and not obstructed. Ensure there are no obstructions to the air intake or exhaust vents. Confirm the unit is set to a 'Cool' mode, not just 'Fan'. - Unit is noisy:
Check if the unit is installed securely and level in the window. Vibrations can cause noise. Ensure no foreign objects are inside the unit or obstructing the fan blades. - Water leakage:
Confirm the unit is slightly tilted outwards to allow proper drainage of condensation. Check if the drain pan is clear of debris. - Reduced airflow:
Clean the air filter. Ensure the front grille is not blocked.
If the problem persists after attempting these solutions, please contact customer support.
Product Specifications
| Specification | Value |
|---|---|
| Brand | Cool-Living |
| Model Number | LS-WAC5 |
| Cooling Power | 5000 British Thermal Units (BTU) |
| Seasonal Energy Efficiency Ratio (SEER) | 9.7 |
| Voltage | 115 Volts |
| Floor Area Coverage | 150 Square Feet |
| Noise Level | 56 dB |
| Refrigerant | R 410A |
| Item Weight | 55.2 pounds |
| Form Factor | Window |
| Special Feature | Dust Filter, Fast Cooling |
Warranty and Customer Support
This Cool Living product is backed by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including coverage duration and claim procedures.
For any questions, technical assistance, or warranty claims, please contact Cool-Living Customer Support. Contact information can typically be found on the product packaging or the official Cool-Living website.