Interlogix TX-1012-01-1
Interlogix Micro Crystal Door/Window Sensor User Manual
Model: TX-1012-01-1 (60-688-95)
1. Introduction
This user manual provides detailed instructions for the installation, operation, and maintenance of your Interlogix Micro Crystal Door/Window Sensor. This compact wireless sensor is designed to detect the opening and closing of doors and windows, providing essential security monitoring for your home or business when integrated with a compatible alarm system.
2. Safety Information
Please read and understand all safety instructions before installing or operating this device. Failure to do so may result in damage to the product, property, or personal injury.
- Battery Safety: Use only the specified battery type (1 CR2 battery). Do not mix old and new batteries. Do not dispose of batteries in fire.
- Environmental Conditions: Do not expose the sensor to extreme temperatures, high humidity, or direct water contact.
- Disassembly: Do not attempt to disassemble or modify the sensor. This will void the warranty and may cause damage.
- Placement: Ensure the sensor is mounted securely to prevent accidental detachment.
3. Package Contents
Verify that all items are present in your package:
- Interlogix Micro Crystal Door/Window Sensor (Main Unit)
- Magnet (for door/window frame)
- Mounting Hardware (e.g., 3M adhesive tape, screws)
- CR2 Battery (may be pre-installed with a pull tab)
4. Setup and Installation
Follow these steps to install and integrate your sensor with your security system.
4.1. Battery Installation
The sensor requires one CR2 battery. If a plastic pull tab is present, remove it to activate the battery. If not, open the sensor casing (refer to diagram if available) and insert the CR2 battery, observing polarity.

Figure 1: Interlogix Micro Crystal Door/Window Sensor shown next to a US quarter coin, illustrating its compact size. The main sensor unit is on the right, and the smaller magnet component is on the left.
4.2. Sensor Placement
Choose a suitable location on your door or window frame. The main sensor unit should be mounted on the stationary frame, and the magnet on the moving part (door or window sash). Ensure the sensor and magnet are aligned and within 0.5 inches (1.27 cm) of each other when the door/window is closed.
4.3. Mounting the Sensor
You can mount the sensor using either the included adhesive tape or screws.
- Adhesive Mounting: Clean the surface thoroughly. Peel the backing from the adhesive tape and firmly press the sensor and magnet into place. Hold for 30 seconds to ensure good adhesion.
- Screw Mounting: For a more secure installation, use the provided screws. Mark the screw holes, pre-drill if necessary, and secure the sensor and magnet to the frame.
4.4. Learning the Sensor into Your Alarm System
This sensor is compatible with various Interlogix and GE Simon security systems. The exact procedure for "learning" the sensor into your system may vary. Consult your alarm system's user manual for specific instructions. Generally, the process involves:
- Accessing the system's programming mode (often requires a master code).
- Selecting the option to add a new wireless sensor or zone.
- Triggering the sensor (e.g., by opening and closing the door/window, or removing the battery pull tab) to transmit its unique ID to the control panel.
- Assigning the sensor to a specific zone and configuring its type (e.g., "Entry/Exit," "Perimeter").
- Exiting programming mode and testing the sensor.
Note: Ensure your system's transmission frequency is compatible with this sensor (e.g., 319.5 MHz for some GE Simon systems).
5. Operating Instructions
Once installed and learned into your alarm system, the Interlogix Micro Crystal Door/Window Sensor operates automatically.
- When the door or window is closed, the sensor and magnet are in close proximity, indicating a secure state.
- When the door or window is opened, the sensor and magnet separate. The sensor detects this change and transmits a signal to your alarm control panel.
- Depending on your system's programming, this signal can trigger an alarm, activate a chime, or simply log the event.
6. Maintenance
Regular maintenance ensures optimal performance of your sensor.
6.1. Battery Replacement
The sensor will typically send a low battery signal to your control panel when the battery needs replacement. To replace the battery:
- Put your alarm system in test mode or disarm it to prevent false alarms.
- Carefully open the sensor casing.
- Remove the old CR2 battery.
- Insert a new CR2 battery, ensuring correct polarity.
- Close the sensor casing securely.
- Test the sensor to confirm it is communicating with the control panel.
6.2. Cleaning
Wipe the sensor with a soft, dry cloth. Do not use liquid cleaners or abrasive materials.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Sensor not responding / Not learning into system |
|
|
| False alarms |
|
|
| Low battery warning on panel | Battery is low. | Replace the CR2 battery as described in Section 6.1. |
8. Specifications
- Model: TX-1012-01-1 (also known as 60-688-95)
- Brand: Interlogix
- Product Dimensions: 1.75 x 0.95 x 0.5 inches
- Item Weight: 0.8 ounces
- Battery Type: 1 x CR2 (required)
- Operating Frequency: Typically 319.5 MHz (verify with your system)
- Manufacturer: GE Security Interlogix
- Date First Available: May 10, 2014
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your complete security system or contact your authorized Interlogix dealer or installer. Keep your purchase receipt for warranty claims.
Note: This sensor is designed to be part of a larger security system. For comprehensive support, always consult the primary system's documentation and support channels.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.